Figure 6: manual control

not, the device does not accept manual output control requests and only scheduled switching and the

Watchdog

feature are in operation. Pressing

All off

button will turn all outputs OFF.

5.1.2

Output status and configuration

On the left side of the window, click

Status & configuration

, the list of ports and status information

appears in the right window.

To setup specific port select in the column

Select

and click

Modify

.

On the new page that will appear you can set up detailed parameters of this specific port. Signifi-

cance of the individual parameters is described in the following text.

Output configuration

No.:

Port number (0 - 3)

Name:

Port (Output) name

PON state:

Default output state after NETIO power on – if you tick the checkbox, the port will be

turned ON after the NETIO start or restart.

Manual control:

If you select this option it will be possible to control the output manually.

Time control:

If you select this option the port will be switched on by timer the configuration of

which is given below.

Timer mode:

Specifies how often the scheduled ON/OFF switching will be performed. Op-

tions:

ONCE

- event will occur only once,

DAILY

- event will be triggered everyday or

WEEKLY

-

8

Summary of Contents for NETIO-230B

Page 1: ......

Page 2: ...nufacturer is not responsible for possible damage caused by improper usage or usage in unsuitable environment Device has been designed for indoor use only Do not use the device during the strong vibra...

Page 3: ...ion 8 5 2 System configuration 10 5 2 1 Configuration of network parameters 11 5 2 2 E mail configuration 11 5 2 3 Date and time settings 12 5 2 4 Manage users 13 5 2 5 Firmware update 14 5 3 Serial P...

Page 4: ...rs electric entrance gates security surveillance systems or any other 230V appliance directly or using the timer 1 1 Features Built in web server Supports wide range of Internet browsers Internet Expl...

Page 5: ...d Internet browser Microsoft Internet Explorer Opera Mozilla Firefox 2 Interface Description 2 1 Side View Figure 1 side view 1 Fuse housing for main fuse 2 Device ON OFF switch 3 RJ 45 connector netw...

Page 6: ...using the Ethernet cable with RJ 45 connectors Use cross cable when the device is directly connected to the PC 2 Connect the power cable to power outlet 3 Connect devices that you want to control to...

Page 7: ...s are made to the device settings Utility will update the settings of your NETIO and show device list with changed parameters If there is DHCP server in your network and you are not willing to change...

Page 8: ...trol the Menu on the left side Output Manual control page will show up figure 6 NETIO 230B can control all four outputs at the same time Choose which ports should be turned ON OFF and click Apply If y...

Page 9: ...d parameters of this specific port Signifi cance of the individual parameters is described in the following text Output configuration No Port number 0 3 Name Port Output name PON state Default output...

Page 10: ...Figure 7 set up ports Figure 8 output configuration 9...

Page 11: ...it is possible to setup maximum allowed number of output restarts default value 3 Enable Turning on the Watchdog feature IP address IP address of the network device that will be monitored Timeout Max...

Page 12: ...web interface Device name allows you to insert the name of your device for easier identification in the future Firmware version is just informative and shows the current firmware version After you mak...

Page 13: ...nd the system date and time settings will appear on the right NETIO 230B supports two methods of getting the right date and time values It can be entered manually or obtained automatically from the SN...

Page 14: ...me mManual local time set up with SNTP server synchronization off Daylight saving time and local time offset works both for automatic and SNTP set up If you do not specify Local Time Offset when the t...

Page 15: ...y three seconds the Continue button is activated Click on it Now insert the firmware file xnetio bin and click Update Approximately two minutes procedure of firmware upload will follow After the firmw...

Page 16: ...it number transmitted as 32 digit hexadecimal number 5 3 2 Communication via KSHELL interface To connect to your NETIO 230B please follow these steps 1 Open command prompt 2 Enter the command telnet 1...

Page 17: ...in name crypted password User login with encrypted password version Shows firmware version alias Shows device name quit Logout If system changes have been made device restart is done reboot Logs out c...

Page 18: ...mode once daily weekly Selection of timer option on time Output ON time off time Output OFF time week sched Number consisting of seven digits 0 or 1 first digit stands for Monday and the last one for...

Page 19: ...vice will fail to respond to Ping commands after the third restart the output will stay OFF You will be notified by warning e mail after each reset of the output system eth Shows current network inter...

Page 20: ...te Switches the system to firmware upgrade mode system reset to default Resets all device settings to factory default values After sending this com mand factory default values are restored and the sys...

Page 21: ...The buttons correspond to outlets 1 4 from left to right 5 5 LED status indicators The LED indicators on the device are used to inform the user not only about the output status but also communicate ce...

Page 22: ...To replace the fuse unscrew the fuse holder ideally using a flat screwdriver Always use an identical replacement fuse 250V 10A type F After insertion of the correct fuse replace the plastic holder and...

Reviews: