background image

event will be triggered once per week.

ON time:

date and time for switching the output ON, if you select

DAILY

mode, this is the date and

time of first execution

OFF time:

Date and time to switch the output OFF. If you select the

DAILY

mode, this is the date

and time of first execution

Week schedule:

Select in which weekdays the

Timer

control should be in operation.

Interrupt delay:

Time in seconds for which the output should be turned OFF when the

Interrupt

function is used either in the manual mode or when the

Watchdog

feature is in operation.

Watchdog

Watchdog

feature allows monitoring of proper operation of network devices. If the monitored device

does not respond to a Ping command within the specified time, the power outlet with enabled watchdog
will be turned OFF for a specified time and then switched back ON. To avoid cycle power OFF/ON of
defective monitored device, it is possible to setup maximum allowed number of output restarts (default
value 3).

Enable:

Turning on the

Watchdog

feature.

IP address:

IP address of the network device that will be monitored.

Timeout:

Maximum Ping response time.

PON delay:

Time (in seconds) for which the Watchdog feature will be inactive after the output

restart. During this interval the monitored device should recover its normal operation after being
restarted.

Ping interval:

Interval (in seconds) in which the Ping requests to the monitored device will be

sent.

Max retry:

Maximum allowed number of output restarts for the case that monitored device does

not respond to a Ping command. After the maximum number of retries is reached the output will
stay OFF.

Retry POFF:

enables

Max retry

option

Send e-mail:

Sends out an informative e-mail that the monitored device did not respond and was

restarted.

Save your new settings by pressing the

Apply

button.

5.2

System configuration

In this section the user can change network and e-mail parameters, system time, administrate user
accounts or perform the firmware upgrade.

10

Summary of Contents for NETIO-230B

Page 1: ......

Page 2: ...nufacturer is not responsible for possible damage caused by improper usage or usage in unsuitable environment Device has been designed for indoor use only Do not use the device during the strong vibra...

Page 3: ...ion 8 5 2 System configuration 10 5 2 1 Configuration of network parameters 11 5 2 2 E mail configuration 11 5 2 3 Date and time settings 12 5 2 4 Manage users 13 5 2 5 Firmware update 14 5 3 Serial P...

Page 4: ...rs electric entrance gates security surveillance systems or any other 230V appliance directly or using the timer 1 1 Features Built in web server Supports wide range of Internet browsers Internet Expl...

Page 5: ...d Internet browser Microsoft Internet Explorer Opera Mozilla Firefox 2 Interface Description 2 1 Side View Figure 1 side view 1 Fuse housing for main fuse 2 Device ON OFF switch 3 RJ 45 connector netw...

Page 6: ...using the Ethernet cable with RJ 45 connectors Use cross cable when the device is directly connected to the PC 2 Connect the power cable to power outlet 3 Connect devices that you want to control to...

Page 7: ...s are made to the device settings Utility will update the settings of your NETIO and show device list with changed parameters If there is DHCP server in your network and you are not willing to change...

Page 8: ...trol the Menu on the left side Output Manual control page will show up figure 6 NETIO 230B can control all four outputs at the same time Choose which ports should be turned ON OFF and click Apply If y...

Page 9: ...d parameters of this specific port Signifi cance of the individual parameters is described in the following text Output configuration No Port number 0 3 Name Port Output name PON state Default output...

Page 10: ...Figure 7 set up ports Figure 8 output configuration 9...

Page 11: ...it is possible to setup maximum allowed number of output restarts default value 3 Enable Turning on the Watchdog feature IP address IP address of the network device that will be monitored Timeout Max...

Page 12: ...web interface Device name allows you to insert the name of your device for easier identification in the future Firmware version is just informative and shows the current firmware version After you mak...

Page 13: ...nd the system date and time settings will appear on the right NETIO 230B supports two methods of getting the right date and time values It can be entered manually or obtained automatically from the SN...

Page 14: ...me mManual local time set up with SNTP server synchronization off Daylight saving time and local time offset works both for automatic and SNTP set up If you do not specify Local Time Offset when the t...

Page 15: ...y three seconds the Continue button is activated Click on it Now insert the firmware file xnetio bin and click Update Approximately two minutes procedure of firmware upload will follow After the firmw...

Page 16: ...it number transmitted as 32 digit hexadecimal number 5 3 2 Communication via KSHELL interface To connect to your NETIO 230B please follow these steps 1 Open command prompt 2 Enter the command telnet 1...

Page 17: ...in name crypted password User login with encrypted password version Shows firmware version alias Shows device name quit Logout If system changes have been made device restart is done reboot Logs out c...

Page 18: ...mode once daily weekly Selection of timer option on time Output ON time off time Output OFF time week sched Number consisting of seven digits 0 or 1 first digit stands for Monday and the last one for...

Page 19: ...vice will fail to respond to Ping commands after the third restart the output will stay OFF You will be notified by warning e mail after each reset of the output system eth Shows current network inter...

Page 20: ...te Switches the system to firmware upgrade mode system reset to default Resets all device settings to factory default values After sending this com mand factory default values are restored and the sys...

Page 21: ...The buttons correspond to outlets 1 4 from left to right 5 5 LED status indicators The LED indicators on the device are used to inform the user not only about the output status but also communicate ce...

Page 22: ...To replace the fuse unscrew the fuse holder ideally using a flat screwdriver Always use an identical replacement fuse 250V 10A type F After insertion of the correct fuse replace the plastic holder and...

Reviews: