User’s Manual
NETIO-230A
www.koukaam.se
10
5.1.2.1
Specific output configuration
No.:
Output number (1 – 4)
Name:
Output name
PON state:
Default output status after NETIO-230A power up – if you tick the checkbox,
connected device will be turned ON after the NETIO starts or restarts.
Manual control:
If you select this option it will be possible to control the output manually.
Timer control:
If you select this option the output will be controlled automatically based on
specified schedule.
Timer mode:
Specifies how often the scheduled ON/OFF switching will be performed.
Options:
•
ONCE
– event will occur only once on specified date and time
•
DAILY
– event will be triggered every day
•
WEEKLY
– event will be triggered every day based on selected week
days
ON time:
Date and time to switch the output ON. If you select the DAILY mode it is the
date and time of the first execution.