22
Failures
Technical data
No.
Fault
Reason
Remedies
1.
The heater does not heat
water and a signal lamp
does not work.
Supply power system failure.
Check safety fuses.
A temperature controller failure. Replace the temperature
controller (service)
2.
The heater does not heat
water and a signal lamp
works.
Heating box failure.
Replace the damaged unit.
(service)
A thermal cut-out problem
Turn on or exchange the
thermal cut-out (service)
3.
The heater heats water
and a signal lamp does
not work.
A signal lamp failure
Replace the lamp. (service)
Type
POC.D
5/2
POC.G
5/2
POC.Gb
5/2
POC.D
5/600
POC.G
5/600
POC.Gb
5/600
Capacity
l
5
Type
POC.D
10/2
POC.G
10/2
POC.Gb
10/2
POC.D
10/600
POC.G
10/600
POC.Gb
10/600
Capacity
l
10
Voltage
220 - 240V~
Rated power
W
2000
600
Rated current
A
8,3 - 9,1
2,5 - 2,7
Temperature range
°C
23 - 70
Pressure rating
MPa
0,6
Dimensions (height x
width x depth)
POC5
mm
427 x 285 x 163
POC10
470 x 329 x 239
Weight (without water)
POC5
kg
4,4
POC10
6,1
Safety class
IP24
Water heater fittings
G 1/2"
Water connection (tap mixer)
-
-
G 1/2”
-
-
G 1/2”