Kospel EPS - 3,5 Manual Download Page 5

                                                       ENG-001B/p.410                                                         5

Technical data

EPS water heater

3,5

4,4

5,5R

Rated power 

kW

3,5

4,4

5,5/4,4

Rated voltage

230V~

Rated current

A

15,2

19,1

23,9/19,1

Min. supply water pressure

MPa

0,12

Operating point

l/min

1,1

1,7

2,0

Efficiency (at 

t = 30°C)

l/min

1,7

2,1

2,6/2,1

Overall dimension (length without a tap x width x depth)

mm

211 x 140 x 70

Weight (with a tap)

kg

~1,4

Conductor to connect with electrical installation (1.2m long)

with assembly terminals

Min. water resistivity at 15°C

Ω

cm

1100

Fuse rated current 

A

16

20

25

Min. connecting wires section

mm

2

3 x 1,5

3 x 2,5

The maximum allowed network impedance

0,34

0,31

Water supply pipe section

G1/2"

Safety class

IP 25

Maintenance

5

To ensure a long and faultless work of the appliance you should carry out a seasonal cleaning of the 

filter [5] in your individual capacity (this duty does not belong to a guarantee service). 

To clean the heater do the following (Fig.5).

1.  Cut off water and electric supply.
2.  Disconnect the heater from the tap set (see ‘Installation’).
3.  Take the filter out [5] from the fittings at cold water inlet [12].
4.  Clean the filter.
5.  Install the filter into the former position.
6.  Fix the heater on the tap set.
7.  Turn  on  the  cold  water  tap  on  –  check  connections  for  

leaks.

8.  Vent the installation (see ‘Venting’).

ATTENTION!

The filter should be cleaned after the repair of a water system, when a lot of effluent appears 

or after a year of operation.

Fig.5   Filter cleaning

 

[5]  –  filter

 

[8]  –  tap set

 

[12]  –  inlet – cold water

Reviews: