Press [1] to switch the boiler on or off. When indicator [3] is on the boiler is working. 

After switching the boiler off the circulation pump will still operate for 90 sec. When the 

indicator [4] flickers and the button [1] is on it means that the boiler haven’t achieved 

required flow level. To start economy mode press button [2] (indicator [5] is on). It limits 

the power of boiler, the unit heats with 2/3 of nominal power. Indicator [4] indicates that 

the boiler is heating. 

When the indicator [4] flickers it means that the boiler haven’t achieved required flow 

level and the heating is off. To set the temperature press [7] or [8] button.

The display [6] shows the current setting of outlet temperature. When the indicator flick-

ers it means that the temp. is 2,5°C below of temp. that shows other indicators.

Flashing indicator [3] sygnalizes defect of master’s appliance connecting installation 

(open NA jumper).

[1] -  boiler „on” button

[2] -  economy mode button

[3] -  boiler „on” indicator 

[4] -  heating „on” indicator

6

2

7

1

8

5

4

3

e

40  50  60  70  80

45  55  65  75  85 

O

 

C

e

[5] -  economy mode „on” indicator

[6] -  temperature setting indicator

[7] -  increase temp. 

[8] -  decrease temp.

Control panel

Summary of Contents for EKCO.R2

Page 1: ...Assembly and operating manual Electric Central Heating Flow Boiler EKCO R2...

Page 2: ...e and knowledge about the product provided that they have been given supervision or instruction concerning safe usage of the appliance and that they are aware of potential dangers that might result fr...

Page 3: ...rough the boiler and reduces a noises in installation during the thermostatic valves closing The valve must be installed in by pass conduit before the boiler according to manufacturer s instruction 7...

Page 4: ...tral heating system 5 Connect a boiler to the electrical system 6 Fix the room thermostat in accordance with manual instruction 7 Connect the room thermostat by using two wires 2 x 0 35 mm2 to the NAe...

Page 5: ...st be installed in horizontal position accordingly to flow direction see arrow on the filter body with the magnetic insert chamber to the bottom Connection to the three phase electrical system PNL poi...

Page 6: ...oper flow through the boiler is reached 4 indicator is on with a constant light The pump should self vent after a short period of running if necessary assist the venting process in the following way c...

Page 7: ...When the indicator 4 flickers it means that the boiler haven t achieved required flow level and the heating is off To set the temperature press 7 or 8 button The display 6 shows the current setting of...

Page 8: ...tion Indicators on the front panel do not light up no power supply for the boiler Check parameters of the power network and fuses Contact your local authorised service the indicator 4 red is flickerin...

Page 9: ...e MPa 0 3 Min pressure MPa 0 05 Outflowing water temp C 35 85 Max water temp C 100 Overall dimensions height x width x depth mm 660 x 380 x 175 Weight kg 18 Water connection G 3 4 Safety class IP 22 T...

Page 10: ...5x1 5 Max connecting wires section mm2 3x16 5x16 The maximum allowed network impedance 0 27 0 17 0 15 0 27 Rated power kW 12 15 18 21 24 Rated voltage 380V 3N Rated current A 3x18 3 3x22 8 3x27 4 3x3...

Page 11: ...uipment for recycling Appropriate utilisation of used product prevents potential negative environmental influences that may occur as a result of inappropriate handling of waste In order to get more de...

Page 12: ...KOSPEL S A 75 136 Koszalin ul Olchowa 1 tel 48 94 31 70 565 serwis kospel pl www kospel pl...

Reviews: