Before switching on the main power supply, the AC power should be checked to ensure that the
supplied voltage fluctuation range does not exceed ±10% of the voltage and frequency indicated by
the equipment. This check is especially important for voltage fluctuations that can occur in high load
situations.
3.
The dehumidifier must be grounded and a power disconnect switch set to ensure that the unit is
powered off during inspection and service.
4.
The fuse current of the power supply fuse is 1.5 to 2 times the rated current of the installed
dehumidifier. The fuse should be installed in the dehumidifier attachment. The power supply cable
and main fuse are optional to handle the correct operating power of the dehumidifier. Fuse rating:
10A 250V, 16A 250V.
5.
If the power cord is damaged, it must be replaced by the manufacturer or a professional authorized
person in order to avoid danger.
6.
Placing. When the dehumidifier is working, make sure the
Minimum distance between two machines is 10cm
Minimum distance between air outlet and the top is 200cm
Minimum distance between the back and the wall is 20cm