KOSMEN KM-480S User Manual Download Page 4

 

1.

 

Important Notice 

 

 

Always keep the devices in the vertical position, on the flat surface and certainly at all times. 

 

Make sure the minimum of 300mm (1”) between the edges of equipment and any flammable 
materials. 

 

Don’t hide the air suction inlet and radiator grille from the devide. 

 

For indoor use only. 

 

Not suitable for use in cabinet, closet, boats, caravans or similar locations. 

 

Leave the unit to stand for one hour before connecting to the mains supply after transport or 
when it has been tilted (e.g. during cleaning). 

 

The mains supply must conform to the specification shown on the rating plate at the back of 
the unit. 

 

Avoid  overloading  circuits,  which  is caused  by  using  more electrical  amps  than  your  wiring 
can support. Overloading electrical wires can cause excessive heat and electrical fires. 

 

Avoid being abandoned. 

 

Check the power cord carefully. Make sure that it is not punctured or frayed. Inspect the plug 
to ensure that the prongs are secure and the plastic surrounding it is not cracked. 

 

Do not suddenly unplug the power plug while the machine is operating. Before turning on or 
off the machine must use switch on the control panel. 

 

Before moving the unit, turn off all controls, then unplug and empty the water tank. 

 

Don't use bug sprays or other flammable cleaners on the unit. 

 

Never pour or spray water over the unit. 

 

This appliance can be used by children aged from 8 years and above and persons with reduced 
physical, sensory or mental capabilities or lack of experience and knowledge if they have been 
given supervision or instruction concerning use of the appliance in a safe way and understand 
the  hazards  involved.  Children  shall  not  play  with  the  appliance.  Cleaning  and  user 
maintenance shall not be made by children without supervision. 

 

Only a licensed professional is allowed to dismantle or modify the appliance. 

 

Suggested to send the appliance for professional maintenance periodically. 

Summary of Contents for KM-480S

Page 1: ...Industrial Dehumidifier User Manual KM 480S www kosmen vn...

Page 2: ...1 2 Function of the Button 2 2 1 Operation 2 2 2 Features 4 3 Operating Instructions 4 3 1 Dehumidifying Running 4 3 2 Drain Indicator 5 4 Device Installation 5 5 Specification 7 6 Error Code Explana...

Page 3: ...b o quan tr ng 09 2 C c n t ch c n ng 10 2 1 V n h nh 10 2 2 Ch c n ng 12 3 H ng d n v n h nh 12 3 1 Ch y m y h t m 12 3 2 n b o tho t n c 13 4 C i t thi t b 14 5 Th ng s k thu t 15 6 Gi i th ch m l i...

Page 4: ...ke sure that it is not punctured or frayed Inspect the plug to ensure that the prongs are secure and the plastic surrounding it is not cracked Do not suddenly unplug the power plug while the machine i...

Page 5: ...2 2 Function of the Button 2 1 Operation...

Page 6: ...3...

Page 7: ...l operating range 10 90 6 If the dehumidifier is not used for a long time remove the power cord or power off 7 The function of the memory system the function can function before the power is turned of...

Page 8: ...the pipe from being too long or the pressure is formed in the pipe when the water outlet is blocked The water flow is not smooth resulting in water leakage Inspection and Maintenance Parts 1 3 months...

Page 9: ...fuse current of the power supply fuse is 1 5 to 2 times the rated current of the installed dehumidifier The fuse should be installed in the dehumidifier attachment The power supply cable and main fus...

Page 10: ...Drainage Dimensions 1030 510 1815 mm Net Weight 182 KGS 6 Error Code Explanation Fault Code The failure How to do with it E1 Temperature sensor breakdown To replace with new temperature sensor E2 Humi...

Page 11: ...iate 2 The front and back may be blocked 3 Dehumidification time isn t enough 4 Door and window may be open 5 Temperature 5 or 38 1 Set appropriate humidity 2 Clear the obstructions 3 Keep waiting 4 C...

Page 12: ...i m tra d y i n c n th n m b o r ng n kh ng b th ng ho c s n Ki m tra ph ch c m m b o c c u c m c ch c ch n v l p nh a bao quanh kh ng b n t Kh ng c r t ph ch c m i n t ng t khi m y ang v n h nh Tr c...

Page 13: ...10 2 C c n t ch c n ng 2 1 V n h nh...

Page 14: ...11...

Page 15: ...m so t m 10 90 6 N u m y h t m kh ng c s d ng trong m t th i gian d i h y r t d y ngu n ho c t t ngu n 7 H th ng c ch c n ng ghi nh ch c n ng n y c th ho t ng tr c khi t t ngu n trong v ng 72 gi sau...

Page 16: ...n c tr nh tr ng h p ng ng qu d i ho c t o p l c trong ng khi ng tho t n c b t c D ng n c ch y kh ng th ng su t d n n r r n c Ki m tra v B o tr C c b ph n 1 3 th ng 12 th ng M ng l c V sinh m ng l c M...

Page 17: ...p v t n s m thi t y u c u Vi c ki m tra n y c bi t quan tr ng i v i c c dao ng i n p c th x y ra trong c c t nh hu ng qu t i 3 M y h t m ph i c n i t v t c ng t c ng t i n m b o thi t b c t t ngu n tr...

Page 18: ...pply 380V 50Hz Operating Temp 5 38 Water Tank Drainage Dimensions 1030 510 1815 mm Net Weight 182 KGS 6 Gi i th ch m l i M l i L i H ng x l E1 S c c m bi n nhi t Thay c m bi n nhi t m i E2 S c c m bi...

Page 19: ...u ng h t m kh ng t y u c u 1 C i t m kh ng ph h p 2 M t tr c v m t sau c a m y h t m c th b c n tr 3 Th i gian h t m c th kh ng 4 C a ra v o v c a s ang m 5 Nhi t trong nh th p h n 5 ho c cao h n 38...

Page 20: ...iep Binh Phuoc Thu Duc City Ho Chi Minh City Vietnam Ha Noi office No 3 Lane 495 Nguyen Trai Thanh Xuan Nam Ward Thanh Xuan District Ha Noi City Vietnam Da Nang office No 385B Hai Phong Tan Chinh Ward...

Reviews: