Grounding JetNet 6059G
There is one grounding screw on the bottom side
of JetNet 6059G. Connect the frame grounding
of JetNet 6059G to the grounding surface to
ensure safety and prevent noise to interfere
communication.
Wiring the Power Inputs
1. Insert the positive and negative wires into the V+ and V- contact on the terminal block
connector.
Wiring the Relay Output (DO)
The relay output contacts are in the bottom side as shown on Figure-3. The relay output (DO)
LVFRQWUROOHGE\WKHSUHGH¿QHGRSHUDWLQJUXOHV7RDFWLYDWHUHOD\RXWSXWIXQFWLRQSOHDVHUHIHUWR
the User’s Manual for the Relay Output information.
2. Tighten the wire-clamp screws to prevent the power wires from being loosened.
Notes:
The recommended working voltage is DC 24V (Input range: DC10.5~ 60 V),
maximum power consumption is 20 Watts.
Note:
The relay contact only
supports 1A current, DC 24V.
It is not recommended to apply
voltage and current higher than
WKHVSHFL¿FDWLRQV
Figure-3