![Korenix JetNet 4500 Series User Manual Download Page 56](http://html1.mh-extra.com/html/korenix/jetnet-4500-series/jetnet-4500-series_user-manual_1997843056.webp)
Korenix JetNet 4500 Series Industrial Managed Ethernet Rail Switch User’s Manual
3-38
Power Inputs Alarm Configuration
Click the Power Alarm Configuration folder
Field Description
Power1
Check Power 1 box to enable Power fault alarm contact.
Switch’s fault alarm contacts will close if PWR1 is off or PWR1
fails
Power2
Check Power 2 box to enable Power fault alarm contact.
Switch’s fault alarm contacts will close if PWR2 is off or PWR2
fails
System Log
System Log is useful to provide system administrator remote monitoring switch events history
How to:
By providing system administrator three options, sending system log to switch itself at
client end or to server end or both ends, users can configure the monitoring type in “System Log
Configuration” folder first then go to “Event Configuration” folder to select events to be monitored.