Korenix JetNet 4500 Series User Manual Download Page 34

 

  Korenix JetNet 4500 Series Industrial Managed Ethernet Rail Switch User’s Manual 

3-16 

ALA — Alaskan Standard 

-9 hours 

3 am 

HAW — Hawaiian Standard 

-10 hours 

2 am 

Nome, Alaska 

-11 hours 

1 am 

CET — Central European 
FWT — French Winter 
MET — Middle European   
MEWT — Middle European 
Winter 
SWT — Swedish Winter   

+1 hour 

1 pm 

EET — Eastern European, 
USSR Zone 1 

+2 hours 

2 pm 

BT — Baghdad, USSR Zone 2

+3 hours 

3 pm 

ZP4 — USSR Zone 3 

+4 hours 

4 pm 

ZP5 — USSR Zone 4 

+5 hours 

5 pm 

ZP6 — USSR Zone 5 

+6 hours 

6 pm 

WAST — West Australian 
Standard 

+7 hours 

7 pm 

CCT — China Coast, USSR 
Zone 7 

+8 hours 

8 pm 

JST — Japan Standard, USSR 
Zone 8 

+9 hours 

9 pm 

EAST — East Australian 
Standard GST 
Guam Standard, USSR Zone 9 

+10 hours 

10 pm 

IDLE — International Date Line 
NZST — New Zealand Standard 
NZT — New Zealand   

+12 hours 

Midnight 

 

SNTP Server IP

: You can set the IP address of the SNTP server here. 

Switch Timer

: The current time of the JetNet will be shown here.   

Once you finish your configuration, click on 

Apply

 to apply your configuration. 

 

Summary of Contents for JetNet 4500 Series

Page 1: ...Korenix JetNet 4500 Series Industrial Managed Ethernet Switch User s Manual V1 4 Jun 2007 www korenix com...

Page 2: ...4500 Series Industrial Managed Ethernet Switch User s Manual Copyright Notice Copyright 2005 Korenix Technology Co Ltd All rights reserved Reproduction in any form or by any means without permission...

Page 3: ...2 7 Chapter 3 Web based Management 3 1 Introduction 3 2 Preparation for Management 3 2 System Login 3 2 Configuration via the Web based Management Interface 3 3 Menu Bar Introduction 3 3 Configuring J...

Page 4: ...lert Configuration 3 36 Event Configuration 3 37 Power Inputs Alarm Configuration 3 38 System Log 3 38 Chapter 4 Troubleshooting 4 1 Power Connections 4 2 Incorrect Connections 4 2 Faulty or Loosen Ca...

Page 5: ...h JetNet 4500 Series is a managed rail switch that is specially designed for industrial applications The manual is applied to JetNet 4508 and 4508f switches The following topics are covered in this ch...

Page 6: ...an advanced redundant network solution Ring Coupling and Dual Homing technology to assure non stop system operation Korenix Super Ring technology provides network redundancy that can self recover in...

Page 7: ...s This is why the Ethernet collision domain is said to terminate at the switch port That is a two port switch will effectively break a network into two distinct data links or segments An eight port sw...

Page 8: ...packet to be inspected and corrupt or redundant data to be filtered further eliminating unnecessary traffic that often slows a network down Product Features Korenix JetNet 4500 Series products have t...

Page 9: ...500 Series products are shipped with the following items One industrial Managed Ethernet switch One DIN Rail clip attached to the switch One wall mounting plate and six screws Documentation and Softwa...

Page 10: ......

Page 11: ...and configuration The following topics are covered in this chapter Introduction Panel Layout Reset Button LED Indicators DIP Switch Wiring the Power Inputs Wiring the Relay Output Wiring the Ethernet...

Page 12: ...eset Button The Reset button provides users with a quick and easy way to restart JetNet 4500 Series Industrial Ethernet Switch and restore the default settings To restart press the Reset button for 2...

Page 13: ...mitting device LNK ACT of Port 7 JetNet 4508f Off No device is attached Orange The port is operating in full duplex mode Blinks A collision of packets has occurred FDX COL of Port 7 JetNet 4508f Off T...

Page 14: ...driver blade can inadvertently short your terminal connections to the grounded enclosure 1 Insert the positive and negative wires of your DC supply into the V and V contacts of the terminal block conn...

Page 15: ...wired to the center two terminals of this terminal block After the power relay is wired replace this terminal block into its socket Wiring the Ethernet Ports JetNet 4500 Series Industrial Ethernet Swi...

Page 16: ...up link port you will need to wait up to 5 minutes before the data can be sent If the aging time is too short the MAC address table will constantly refresh resulting in excess consumption of switch c...

Page 17: ...emove the DIN Rail clip reverse step 1 Follow the steps below to mount the JetNet to the DIN Rail track 1 First insert the upper end of the DIN Rail clip into the back of the DIN Rail track from its u...

Page 18: ...late to the rear panel of the switch using the six screws provided Tighten these screws to secure the switch to the wall mounting plate 3 Use the slotted holes at each corner of the wall mounting plat...

Page 19: ...Series Industrial Managed Ethernet Switch via a web based interface The following topics are covered in this chapter Introduction Preparation for Web Management System Login Configuration via the Web...

Page 20: ...use the embedded web interface to manage switch operation verify that your JetNet 4500 Series Industrial Ethernet Switch is properly installed on your network and that every PC on this network can ac...

Page 21: ...This section is to display the port status and settings Port Statistics This section is to display the JetNet s port data flow statistics Port Control This section is to configure the JetNet s port se...

Page 22: ...factory default settings Save Configuration This section is to save the JetNet s settings System Reboot This section is to reboot the JetNet Rate Control This section is to set up each port s bandwidt...

Page 23: ...Configured and Actual Symmetric specifies that you need to activate the flow control function of the remote network device in order to let the flow control of that corresponding port of the switch to...

Page 24: ...available when you selected Force mode In Duplex column you can configure the full duplex or half duplex mode of this port The command is only available when you selected Force mode In Flow Control c...

Page 25: ...save your settings Otherwise the settings you made will be lost when the JetNet is powered off Port Mirroring Port mirroring also called port spanning is a tool that allows you to mirror the traffic f...

Page 26: ...members Basically creating a VLAN from a switch is the logical equivalent of physically reconnecting a group of network devices to another Layer 2 switch without actually disconnecting these devices...

Page 27: ...restricted to ports of the same switch Effectively only the switch itself knows the architecture of a port based VLAN while the segments connected to the switch ports have no way of knowing the VLAN...

Page 28: ...n a name for the new VLAN here The Group Name is a reference for the network administrator to identify different VLANs 3 VLAN ID You can type in VLAN ID here the value is between 2 and 4094 The defaul...

Page 29: ...ease note that each VLAN will require a tagged port Different VLANs use these tagged ports to communicate with one another 5 Here you can specify the egress outgoing VLAN frames to be Tagged frames or...

Page 30: ...s remember to select Save Configuration to save your settings Otherwise the settings you made will be lost when the switch is powered off How To Set Up a 802 1q VLAN Reference Example To illustrate a...

Page 31: ...Step 1 1 to 1 3 to create VLAN B 2 Set up Tagged Port Be sure to set up the Tag uplink Port port 8 for our example Thus VLAN A and VLAN B can only communicate with one another via transmission from th...

Page 32: ...first switch s settings and restore them to the second switch This will reduce the time required to set up the second switch Refer to Configuration Backup section for more information IP Configuration...

Page 33: ...Time Protocol NTP used to synchronize computer clocks on the internet You can configure the SNTP settings here for the purpose of synchronizing the clocks of several switches on the network SNTP is ma...

Page 34: ...4 USSR Zone 3 4 hours 4 pm ZP5 USSR Zone 4 5 hours 5 pm ZP6 USSR Zone 5 6 hours 6 pm WAST West Australian Standard 7 hours 7 pm CCT China Coast USSR Zone 7 8 hours 8 pm JST Japan Standard USSR Zone 8...

Page 35: ...ity IP before enabled the IP Security feature Otherwise there will no any IP address can access the device Security IP 1 to 10 You can assign up to 10 specific IP addresses Only these 10 IP addresses...

Page 36: ...very network should have one root bridge and it is usually assigned the lowest bridge ID The bridge with the lowest bridge ID number has the highest priority and is selected as the root bridge If you...

Page 37: ...the rapid state transitions that are possible within RSTP depend upon whether the port of concern can only be connected to one other bridge i e it is served by a point to point LAN segment or if it ca...

Page 38: ...g Master and one of its two member ports will be temporarily blocked this is referred to as the backup port The other member port is called the working port The other switches in the ring are called w...

Page 39: ...Port of R M is the backup path R M will continuously sent hello packet through port 3 to next switch and receive the returned hello packet from port 4 The settings of Switch 1 Ring Master Click the R...

Page 40: ...ibed above on all ring switches Otherwise it will cause an immediate message loop Can 3 Switches Form a Super Ring Topology Here we use 3 JetNet 4508 Industrial Ethernet Switches to form a Super Ring...

Page 41: ...ibed above on all ring switches Otherwise it will cause an immediate message loop Network Redundancy Ring Coupling Ring coupling technology is implemented to extend the Super Ring installed switches c...

Page 42: ...l Port Select any port of JetNet to be the Control Port Port 4 is enabled for Couple Ring Network Redundancy Dual Homing Dual Homing provides an advanced redundancy network solution by connecting swit...

Page 43: ...per Ring protocol enable dual homing feature in switch A B to provide network redundancy by connecting with one Managed Switches Enable Dual Homing Setting Description Factory Default Enable Disable E...

Page 44: ...priority Priority Type Each port has 5 priority types for you to select Port based The port priority will follow the default port priority that you have assigned High middle low or the lowest COS only...

Page 45: ...ter use this field as the QoS service Then the L2 switches attached to the network should have the same policy as the L3 switch or Router This table allows you to configure the queue level for each DS...

Page 46: ...n Report A message sent by a host to the querier to indicate that the host wants to be or is a member of a given group indicated in the report message Leave Group A message sent by a host to the queri...

Page 47: ...Restore File Name You need to specify the correct restore file name here Once you finish configuring the settings click on Apply to apply your configuration TFTP Backup Configuration You can save the...

Page 48: ...Note Remember to click on the Save Configuration button to save your settings Otherwise the settings you made will be lost when the JetNet is powered off Factory Default In this section you can reset...

Page 49: ...click on the Save Configuration button to save your settings Otherwise the settings you made will be gone when the JetNet is powered off Save Configuration Save Configuration allows you to save any c...

Page 50: ...width Port 1 to Port 8 support port ingress incoming traffic and egress outgoing traffic rate control For example let s assume port 1 is 10 Mbps you can set its effective egress rate to be 1 Mbps and...

Page 51: ...of the TCP IP protocol suite JetNet 4500 series supports SNMP v1 and v2c The next figure illustrates an SNMP management operation An SNMP managed network consists of two main components agents and a...

Page 52: ...ntry shows the String Name and the Privilege New Community Strings Fill in fields below to add a new community string and define the permission Read Only or Read Write of accessing SNMP objects then c...

Page 53: ...itch To remove a trap manager select the trap manager in the list and click Remove button New Manager To add a new trap manger fill the following IP address community and trap version fields then clic...

Page 54: ...mail account Confirm Password Re type the password of the email account You can set up to 4 email addresses to receive email alarm from JetNet E mail of Recipient 1 The first email address to receive...

Page 55: ...of a specific ports System Event Warning Email is sent when Device Cold start Power is cut off and then reconnected Power Status One of redundant power PWR1 or PWR2 fails Authentication failure An in...

Page 56: ...2 Check Power 2 box to enable Power fault alarm contact Switch s fault alarm contacts will close if PWR2 is off or PWR2 fails System Log System Log is useful to provide system administrator remote mon...

Page 57: ...to log server Both Enable both Client and Server functions System Log Server IP Input the IP address of Log Server System Log Screen Format Index Date Time Events Reload Click Reload button to update...

Page 58: ...Korenix JetNet 4500 Series Industrial Managed Ethernet Rail Switch User s Manual 3 40...

Page 59: ...s chapter includes the information on general troubleshooting The following topics are covered in this chapter Power Connections Incorrect Connections Faulty or Loose Cables Non standard Cables Improp...

Page 60: ...e fiber cable type matches the fiber model multi mode or single mode For the RJ 45 connectors use the correct UTP or STP cables as required For 10 100M ports use 2 pairs of twisted cables For Gigabit...

Page 61: ...ts own after running for a period of time check for loose power connections power losses or surges at the power outlet You should also verify that your supply voltage remains within the required 12 48...

Page 62: ......

Page 63: ...nd RFC 1213 MIB II RMON1 group 1 2 3 9 The standard MIB groups that JetNet 4500 series supports are MIB II Group SysObject ID SysUptime SysContact SysName SysLocation SysService SystemInterface Bridge...

Page 64: ......

Page 65: ...RFC 1643 Ethernet like MIB RFC1215 Trap MIB IGMP MIB Korenix Private MIB SNMP Trap Support 3 trap stations System Log Provides 1000 system entries for system or remote log server Class of Service Meet...

Page 66: ...ing Tree Interface Number of Ports JetNet4508 8 x 10 100Base TX with Auto MDI MDI X Auto Negotiation functions JetNet4508f 6 x 10 100Base TX with Auto MDI MDI X Auto Negotiation functions 2 x 100Base...

Page 67: ...ature 10 70 Operating Humidity 5 95 non condensing Storage Temperature 40 85 Storage Humidity 5 90 non condensing Regulatory Approvals EMI FCC Class A CE EN55022 EMC Immunity Interface EN61000 4 2 EN6...

Page 68: ......

Page 69: ...he manual updated the description as well Modify Max available security IP is 10 Modify Super Ring configuration method and change the figures of the Super Ring web pages Modify Modify the QoS configu...