23
DIP Switch 6: Power Event Alarm Control, Enable(On)/ Disable (Off)
DIP Switch 7: Not available.
Power Connector
6-pin Removable Terminal Block
Digital Output
Included in 6-pin Removable Terminal Block
Power Requirements
System power
DC 10~60V
with polarity reverses correction
.
Supports Positive/Negative power system
System power
consumption
6Watts / DC 24V
Mechanical
System Installation
DIN Rail mount installation
Enclosure protection
Ingress Protection code - 31
Dimensions
99 (D) x55(W)x 120(H), unit:mm (without Din-rail kit)
Weight
0.505Kg / 0.675Kg with package
Environmental
Operating
Temperature
-25
℃
~75
℃
-40
℃
~75
℃
(wide operating temperature model)
Operating Humidity
0% ~ 95% non-condensing
Storage Temperature
-40
℃
~ 75
℃
Storage Humidity
0%~ 95% non-condensing
Regulatory Approvals
EMI
CE/EN 61000-6-4, CISPR-16-1-2:2003, CISPR-16-2-1:2003,
CISPR-16-2-3:2006, CISPR-22 :2005+A1 :2005(9.6), FCC part 15B
Class A
EMS
CE/ EN 61000-6-2 :2005
IEC 61000-4-2 :2008, IEC 61000-4-3 :2006+A1 :2007,IEC
61000-4-4 :2004, IEC 61000-4-5 :2005, IEC 61000-4-6 :2008, IEC
61000-4-8 :1993+A1 :2000
Safety
Hi-pot Testing – AC 1.5KV
Shock
IEC 60068-2-27
Vibration
IEC 60068-2-6
Free fall
IEC 60068-2-32 with Unit Box