10
Kordis Media Co.,ltd
Data Sheet NCB210X2
EMI
: Shielding will be required for passing certain regulatory emissions tests. Also the choice of video board
and power supply can affect the test result.
Consideration should be given to:
Electrical insulation.
Grounding.
EMI shielding.
Heat & ventilation
Caution
:
Ensure that the adequate insulation is provided for all areas of the PCB with special attention to
high voltage parts such as the inverter.
*** Remarks***
For a specific panel use, One LCD panel sample and full technical specifications for the LCD panel from
the manufacturer are required to test for tuning up screen image. KORDIS can provide engineering service
for customers specific controller development.
Please contact KORDIS. ([email protected])
12. Setup for operation
Once the circuit has been connected, a setup procedure for optimal is requires a few minutes The
following instructions are likely to form the basis of the finished product operation manual.
PC Settings
The PC needs to be set to an appropriate graphics mode that has the same resolution with the LCD panel to
have clear screen image. And the vertical refresh rate should be set to one of 56~75Hz, non – interlaced
signal.
LCD display System Settings
The OSD (On Screen Display) provides certain functions to have clear image and others. This board
supports 4 buttons OSD operation as a standard. The control functions defined on OSD operation are as
below.
Pc Graphics Output: A few guidelines:
Signal quality is very important, if there is noise or instability in the PC graphics output this may
result in visible noise on the display
Refer to the graphic modes table in specification section for supported modes.
Non-interlaced & interlaced video input is acceptable.
Important:
please read the application notes section for more information
.