background image

 

16

 

Kordis Media Co.,ltd 

Data Sheet NCB210X2 

 

POSITION Control

 

 

1) 

Menu 

Down 

     2) 

Select

 

 

 

 
 
 
 

VERTICAL Position 

Procedure 

POSITION > VERTICAL 

> select 

When display image is out of screen, can adjust with this 
function for getting Optimized Image) 
 

CLOCK 

Procedure 

POSITION > CLCOK > select

 

When display image is wrinkled, can adjust with this   
function for getting Optimized Image) 

HORIZONTAL Position 

Procedure 

Menu >    POSITION > HORIZONTAL > select 

 

Adjustment

 

Phase 

Procedure 

POSITION > Phase select

   

When display image is vague, can adjust with this   
function for getting Optimized Image) 

Mismatche
d

Optimized

Mismatch
ed

Optimized

When display image is out of screen, can adjust with this   
function for getting Optimized Image) 
 

Summary of Contents for NCB210X2-DS-AB

Page 1: ...Monitor PC DVI Interface Controller For 800X600 1024X768 Resolutions TFT LCD DATA SHEET TFT LCD Monitor Control Board NCB210X2 DS AB March 2004 Kordis Media Co ltd 3F 1006 9 Sadang Dong Dongjak Ku Seoul 156 090 Korea TEL 82 2 585 8347 FAX 82 2 585 8391 ...

Page 2: ...4 GENERAL SPECIFICATION 5 SYSTEM DESIGN 7 BLOCK DIAGRAM 8 ASSEMBLY NOTES 9 CONNECTION OPERATION 11 OSD 12 OSD FUNCTION 14 CONNECTOR PINOUT JUMPER 19 CONTROLLER DIMENSIONS 27 APPLICATION NOTES 28 TROUBLESHOOTING 29 APPLICABLE GRAPHIC MODE 30 ACCESSORY 30 APPENDIX 31 ...

Page 3: ...3 Kordis Media Co ltd Data Sheet NCB210X2 Revision History No Data Revision Page 1 Preliminary Release A1 ...

Page 4: ...rence Assembly notes Check controller switch jumper settings errors may damage the panel Prepare the PC Video Connect the parts Understand the operation functions IMPORTANT USAGE NOTE This equipment is for use by developers and integrators The manufacturer accepts no liability for damage or injury caused by the use of this product It is the responsibility of the developer integrators or other user...

Page 5: ...DS H 31 80kHz 4 Resolution Support V 55 76Hz OSD Control Menu Left Right Up Down Source Power 5 keys 5 Plug Play VESA DDC 2B Ver1 3 6 Power Connector Input Type IEC320 MALE 3Line Connector Supply Voltage 12VDC 7 Power Consumption Max Power 35W With Back Light Inverter Analog DSUB 15P R G B Separate H V Sync 8 Signal Connector Digital DVI D TMDS TMDS Notes 1 Depends On Panel Resolution S SVGA 800X6...

Page 6: ... DVI D Input DATA CLK VPP 450 500 900 Differential Output Characteristics Description Signal Unit Min Typical Max Remarks TTL LCD Interface RGB Data VPP 3 3 DE Sync Clock VPP 3 3 Clock Freq MHz 25 80 Depends on Mode LCD Power 12V VDC 11 4 12 12 6 LCD Power 5V VDC 4 5 5 5 5 Jumper option LCD Power 3 3V VDC 3 16 3 3 3 5 Jumper option LVDS Interface Differential output VPP mV 250 350 450 Differential...

Page 7: ...to comprise the following 10 DC Power Jack 12V 12 ANALOG VGA Input 5 OSD KEY CABLE 1 LCD PANEL 6 INVERTER CABLE 7 LCD INTERFACE CABLE LVDS 8 OUTPUT POWER 2 INVERTER 4 OSD Board 11 DVI D Input 9 DC Power Jack 12V J1 J12 J12 Jumper for LCD Power 3 LCD controller board J16 J4 Jumper for Panel Type J3 J14 J9 J13 J6 J7 J2 J17 J15 J8 ...

Page 8: ...8 Kordis Media Co ltd Data Sheet NCB210X2 BLOCK DIAGRAM RED GREEN BLUE SYNC DSUB 15P SCALER MCU E2 PROM LVDS 1CH Inverter DC DC Power Control POWER TMDS DVI D ...

Page 9: ...d switches settings to match the target LCD panel 3 LCD connector board Different makers and models of LCD panel require different panel signal connectors and different pin assignments 4 LCD signal cables In order provide a clean signal it is recommended that LCD signal cables should not longer than 30cm If loose wire cabling is utilized these can be a made into a harness with cable ties Care shou...

Page 10: ...nnected a setup procedure for optimal is requires a few minutes The following instructions are likely to form the basis of the finished product operation manual PC Settings The PC needs to be set to an appropriate graphics mode that has the same resolution with the LCD panel to have clear screen image And the vertical refresh rate should be set to one of 56 75Hz non interlaced signal LCD display S...

Page 11: ...power is setting and J4 Target Panel Option switch are set correctly Details referring the jumpers and switches setting table in the following section 6 VGA cable Controller Plug the VGA cable to the connector J6 or J1 of the controller board 7 DIV D Cable Controller Plug the DVI D Cable to the connector J3 or J13 of the controller board 8 Power supply Controller Plug the DC 12V power in to the co...

Page 12: ...s a standard The control functions defined on OSD operation are as below unit mm Appearance Button Function Status HOT Key Power Power on off On Off Menu Activate menu Select Menu Select Auto setting LED Indicates operation status Green Off Amber DOWN UP Cursor control Value Control Down Decrement Up Increment UP Source change UP DOWN POWER ON OFF LED MEN U SEL AUTO 8 5 1 6 3 Source change ...

Page 13: ...ast Increase decrease panel Contrast level total 100 steps H V Position Image H V position control total 100 steps Clock Fine tune the number of sampled data Phase Fine tune the position of sampled data adjust image quality total 31 steps Color Color Temperature control total 100 steps OSD Function OSD position OSD Language OSD Off Timer control Sel input sign Select input signal analog composite ...

Page 14: ...et NCB210X2 OSD FUNCTION BRIGHTNESS CONTRAST Control 1 Menu 2 Select Brightness Procedure Menu BRIGHTNESS CONTRAST Blue Highlight Select Brightness Bright Dark Contrast Procedure Menu Blue Highlight Select Contrast Distinctive Vague ...

Page 15: ... Menu Color Blue Highlight Select Select Blue Highlight RED Color Control select return to Left Status Select Blue Highlight GREEN Color Control Select Blue Highlight BLUE Color Control Color VIDEO Input Mode Procedure Menu Color Blue Highlight Select Select Blue Highlight SHARPNESS select return to Left Status SHAHPNESS Focus of Image COLOR Thickness of Color TINT Tone of Image ...

Page 16: ...POSITION CLCOK select When display image is wrinkled can adjust with this function for getting Optimized Image HORIZONTAL Position Procedure Menu POSITION HORIZONTAL select Adjustment Phase Procedure POSITION Phase select When display image is vague can adjust with this function for getting Optimized Image Mismatche d Optimized Mismatch ed Optimized When display image is out of screen can adjust w...

Page 17: ... SETUP Control 1 Menu Down 2 Select OSD POSITION Function Procedure SETUP OSD POSITION Select OSD POSITION Function Procedure SETUP OSD TIME Select 10 to 60 Sec SOURCE Select Function Procedure SETUP SOUREC Select ANALOG DIGITAL ANALOG DIGITAL ...

Page 18: ...e supporting range POWER SAVER MODE Input Signal is not present This message is disappeared after 5 seconds SELF DIAGNOSTICS Input Signal is not present after power on with power switch This message is not disappeared before power off or activity of input signal AUTO CONFIGURATION Execute AUTO Function ...

Page 19: ...B J7 Connector Output Power 53015 0510 MOLEX J8 Connector DC power Input 20022WR 05A00 YEONHO J9 Connector To OSD Board 53015 0710 MOLEX J12 Switch Panel Power Select Switch HDR5X2 J13 Connector DVI D Input TMDS 12507WR 20 YEONHO J14 Connector LVDS Single LCD interface Signal 12507WR 20 YEONHO J15 Connector Output Power 20022WR 05A00 YEONHO J16 Connector Inverter Connector 53261 1090 MOLEX J17 Con...

Page 20: ...UE BLUE analog input 8 BLUE GND Ground for BLUE Input Signal 9 GREEN GREEN analog input 10 GREEN GND Ground for GREEN Input Signal 11 RED RED analog input 12 RED GND Ground for RED Input Signal J2 12V DC power supply Pin No Symbol Description Pin No Symbol Description Center Vcc 12V Shell GND Ground J4 Panel Type Select Switch Description Pin No Symbol OFF ON 1 XGA SXGA XGA SXGA 2 VGA SVGA VGA SVG...

Page 21: ...10 TMDS DATA1 TMDS DATA1 Differential Positive Signal 11 TMDS DATA1 Shield Shield for TMDS Channel 1 12 NC No Connection 13 NC No Connection 14 5V Power 5 Volt signal for EDID Un powered Monitor 15 GND for 5V Ground for 5 Volt Power pin Sync return 16 HPD Identify the presence of a monitor 17 TMDS DATA0 TMDS DATA0 Differential Negative Signal 18 TMDS DATA0 TMDS DATA0 Differential Positive Signal 1...

Page 22: ...D Ground 6 GND Ground 7 GND Ground 8 GND Ground 9 NC Not connected 10 GND Ground 11 GND Ground 12 DSDA DDC SDA 13 HSYNC Horizontal Sync 14 VSYNC Vertical Sync 15 DSCL Serial Clock Input J7 J15 On board 12V 5V logic power Output Pin No Symbol Description 1 2 12V 12V 3 GND GND 4 5 5V 5V J8 DC power Input Connector Pin No Symbol Description 1 2 12V 12V 3 NC Not connected 4 5 GND Ground ...

Page 23: ...ontrol connector Pin No Symbol Description 1 5V 5V 2 IRQ GREEN LED2 3 LED2 RED LED1 4 LED1 GREEN LED1 5 GND Ground 6 KEY1 Up Power 7 KEY0 Menu Select Down J12 Panel Type Select Switch Description Pin No Symbol OFF ON 1 3 3V 3 3V 2 NC 3 5V 5V 4 NC 5 12V 12V ...

Page 24: ...ial Negative Signal 8 TMDS DATA1 Shield Shield for TMDS Channel 1 9 GND Ground 10 TMDS DATA0 TMDS DATA0 Differential Positive Signal 11 TMDS DATA0 TMDS DATA0 Differential Negative Signal 12 TMDS DATA0 Shield Shield for TMDS Channel 0 13 TMDS CLOCK TMDS DATA0 Differential Positive Signal 14 TMDS CLOCK TMDS DATA0 Differential Negative Signal 15 TMDS CLOCK Shield Shield for TMDS Clock differential Pa...

Page 25: ...le 10 Y2M LVDS 2 Channel Negative Signal for LCD Module 11 GND Ground 12 Y1P LVDS 1 Channel Positive Signal for LCD Module 13 Y1M LVDS 1 Channel Negative Signal for LCD Module 14 GND Ground 15 Y0P LVDS 0 Channel Positive Signal for LCD Module 16 Y0M LVDS 0 Channel Negative Signal for LCD Module 17 GND Ground 18 GND Ground 19 MOD_PWR VDD For LCD Module 12V 5V or 3 3V 20 MOD_PWR VDD For LCD Module 1...

Page 26: ... Summary jumpers setting Referenc e Description Connector Type 3 3V panel power CAUTION Incorrect setting can damage panel 5V panel power CAUTION Incorrect setting can damage panel J12 12V panel power CAUTION Incorrect setting can damage panel ...

Page 27: ...27 Kordis Media Co ltd Data Sheet NCB210X2 CONTROLLER DIMENSIONS 13mm max 1 2m m Max 2 mm 16 2 mm max 6 8mm max 1 2m m 8 0 mm max ...

Page 28: ...n open circuit or closed circuit depending on inverter INVERTER CONNECTION There are 3 potential issues to consider with inverter connection Power ON OFF Brightness DIM ADJ Inverter power This should be matched with the inverter specification Inverter On Off This is a pin provided on some inverter for ON OFF function and is used by this panel controller for VESA DPMS compliance If the inverter doe...

Page 29: ...ly the image adjustment controls will not move the image far enough then test using another graphics card This situation can occur when a graphic card is not close to standard timing or when something is in the graphics line that may affect the signal such as a signal splitter please note that normally a signal splitter will not have any adverse effect Image appearance A faulty panel can have blan...

Page 30: ...31 500 N 37 500 840 640 N 75 000 500 480 800 600 56 Hz 36 000 P 35 156 1024 800 P 56 250 625 600 800 600 60Hz 40 000 P 37 879 1056 800 P 60 317 628 600 800 600 72Hz 50 000 P 48 077 1040 800 P 72 188 666 600 800 600 75Hz 49 500 P 46 875 1056 800 P 75 000 625 600 1024 768 60Hz 65 000 N 48 363 1344 1024 N 60 005 806 768 1024 768 70Hz 75 000 N 56 476 1328 1024 P 70 070 806 768 1024 768 75Hz 78 750 P 6...

Page 31: ...21S1 LG Philips LCD 3 3V SS6S OFF OFF ON ON ON 3 HT10X21 HYDIS 3 3V XS6S OFF OFF ON ON ON 4 HT12X11 HYDIS 3 3V XS6S OFF OFF ON ON ON 5 HT12X12 HYDIS 3 3V XS6S OFF OFF ON ON ON 6 LM150X05 C3 LG Philips LCD 3 3V XS8N OFF OFF OFF OFF ON 7 LM150X06 A3 LG Philips LCD 3 3V XS8N OFF OFF OFF OFF ON 8 LM150X07 B4 LG Philips LCD 3 3V XS8N OFF OFF OFF OFF ON 9 LM150X08 A4 LG Philips LCD 3 3V XS8N OFF OFF OFF...

Reviews: