Parameterization mode charging current:

When  connecting  the  electrical vehicle  to  an  unknown  power  source, 

the maximum possible charging current of the power source should be 

checked before the beginning of the charging procedure.

Example:

  If  the  utilized  power  source  is  fused  for  13A,  the  maximum 

possible charging current on the PERCEDOS

®

 must be reduced by one 

level from 16A to 13A. Otherwise, the power source will be overloaded. 

The fuse can trigger prematurely or the connection cables will be destro-

yed by overheating.

Five different current levels can be set manually. (16A, 13A, 11A, 8A, 

6A). As delivered, the maximum possible charging current is preset at 

16A.  Parameterization  of  the  maximum  possible  charging  current  is 

only possible inactive operating status.

To manually parameterize the maximum possible charging current, pro-

ceed as follows:

•  Check the operating status of the PERCEDOS

®

 and switch from 

active to inactive, if necessary.

Display PERCEDOS

®

 blinks green.

•  Then, press button (0) and button (I) simultaneously and keep 

pressed for approx. 5 seconds.

•  During initial parameterization (delivered status), all of the LED‘s of 

the current indicator light up.  

Current indicator illuminates as yellow bar.

•  If charging current parameterization has already been performed 

and this setting will now be changed, the yellow bar illuminates up 
to the previously set maximum possible current level.

Example:

 

Preset 13A maximum possible charging current corresponds 

to 80% of the bar display.

Reduce maximum possible charging current:

•  Press button (0).

•  Each  time  the  button  is  pressed,  the  maximum  possible  charging 

current  is  reduced  by  one  charging  level  until  the  lowest  charging 

level is reached.

 

Increase maximum possible charging current:

•  Press button (I).
•  Each time the button is pressed, the maximum possible charging 

current is increased by one charging level until the highest charging 
level is reached.

Close charging current parameterization:

•  Parameterization mode is automatically closed if no button is 

pressed for at least 5 seconds.

Yellow current indicator goes out completely.

 

Instruction Manual PERCEDOS

®

Summary of Contents for PERCEDOS

Page 1: ...PERCEDOS by PERCEDOS by Instruction Manual Technical Information...

Page 2: ...d wire and its freedom from faults So that the PERCEDOS can detect external voltage on the protective ground the device must be connected to the electrical vehicle The function external voltage detect...

Page 3: ...otective ground wire is activated PERCEDOS only attached to the vehicle Device is not being supplied with mains voltage device off No visual feedback possible No protective ground monitoring possible...

Page 4: ...reen Battery charging procedure Only possible if the PERCEDOS has not detected any fault and is acti vated Standby Vehicle connection has been detected Charging procedure possible but not yet switched...

Page 5: ...splay PERCEDOS blinks green Then press button 0 and button I simultaneously and keep pressed for approx 5 seconds During initial parameterization delivered status all of the LED s of the current indic...

Page 6: ...ing procedure is permanently switched off if the excessive tempe rature continues to be measured when the lowest charging level of 6A is reached Display PERCEDOS illuminates red Display vehicle and cu...

Page 7: ...allo wed after it is switched off for the fourth time permanent switch off Display PERCEDOS illuminates red Display vehicle and current indicators are off Manual test of the differential fault current...

Page 8: ...fault current function and an operating hours meter monitors the maximum recommended operating time until the next retesting Periodic self test The PERCEDOS checks the differential fault current funct...

Page 9: ...ot switch on charging procedure Have the PERCEDOS checked immediately by an electrician Reset operating hours meter The operating hours meter can be manually reset in inactive operating status For thi...

Page 10: ...NTC resistance optional External temperature observation NTC resistance in power supply plug Vehicle communication Integrated communication modul PWM according IEC 61851 Data port short circuit proof...

Page 11: ...green periodic self test has activated Operating hours exceeded Current indicator 1 Displays illuminates when the vehicle is being actively charged Otherwise no display off 2 Illuminates green momenta...

Page 12: ...l vertrieb kopp euKopp Austria GmbH Theodor Simoneit Stra e 2 A 4160 Aigen Tel 43 7281 6566 0 Fax 43 7281 8790 Technische Beschreibungen Abbildungen und Leistungsangaben stellen keine zugesagten Eigen...

Reviews: