Kopp PERCEDOS Instruction Manual/Technical Information Download Page 4

PERCEDOS 

®

by

4

"Activate/deactivate" PERCEDOS

®

 operating status:

If no fault is detected after commissioning and test sequence, the char-

ging procedure is permitted. For this, the device must be activated  in 

operating status.

•  The PERCEDOS

®

 is delivered inactive.

•  The respective operating status, whether active or inactive, is per-

manently saved in the device even in case of power loss.

•  For every startup or after the return of voltage note which operating 

status the device assumes after fault-free test sequence.

•  If  the  device  was  deactivated  as  its  last  operating  status  inactive, 

the PERCEDOS

®

 must be switched to active so that the vehicle can 

be charged.

Activate PERCEDOS

®

:

•  Press button (I).

•  Charging procedure activated.

Display PERCEDOS

®

 illuminates green.

Deactivate PERCEDOS

®

:

•  Press button (0).

•  The charging procedure is switched off or interrupted.

•  Standby mode.

  Display PERCEDOS

®

 blinks green.

Battery charging procedure:

Only possible if the PERCEDOS

®

 has not detected any fault and is acti-

vated.

Standby

•  Vehicle connection has been detected.
•  Charging procedure possible, but not yet switched on by the vehicle 

electronics.

Current indicators are off.

Display vehicle illuminates red/green.

Charging procedure

•  Charging procedure was switched on by the vehicle electronics.
•  Vehicle battery is being charged.

Maximum possible current level illuminates yellow.

Momentary current level illuminates as a green bar.

Display vehicle blinks green.

Charging procedure concluded:

•  Vehicle batteries are completely charged.

Current indicators are off.
Display vehicle illuminates green.

•  Switch PERCEDOS

®

 to inactive and remove the connections to the 

vehicle and the mains connection.

•  Vehicle operation can be resumed.

Charging procedure not possible:

•  Communication error between the PERCEDOS

®

 and the electrical vehicle.

•  Ventilation required by the vehicle electronics is not present, not 

activated, or faulty

Display vehicle blinks red.

Current indicators are off.

Instruction Manual PERCEDOS

®

Summary of Contents for PERCEDOS

Page 1: ...PERCEDOS by PERCEDOS by Instruction Manual Technical Information...

Page 2: ...d wire and its freedom from faults So that the PERCEDOS can detect external voltage on the protective ground the device must be connected to the electrical vehicle The function external voltage detect...

Page 3: ...otective ground wire is activated PERCEDOS only attached to the vehicle Device is not being supplied with mains voltage device off No visual feedback possible No protective ground monitoring possible...

Page 4: ...reen Battery charging procedure Only possible if the PERCEDOS has not detected any fault and is acti vated Standby Vehicle connection has been detected Charging procedure possible but not yet switched...

Page 5: ...splay PERCEDOS blinks green Then press button 0 and button I simultaneously and keep pressed for approx 5 seconds During initial parameterization delivered status all of the LED s of the current indic...

Page 6: ...ing procedure is permanently switched off if the excessive tempe rature continues to be measured when the lowest charging level of 6A is reached Display PERCEDOS illuminates red Display vehicle and cu...

Page 7: ...allo wed after it is switched off for the fourth time permanent switch off Display PERCEDOS illuminates red Display vehicle and current indicators are off Manual test of the differential fault current...

Page 8: ...fault current function and an operating hours meter monitors the maximum recommended operating time until the next retesting Periodic self test The PERCEDOS checks the differential fault current funct...

Page 9: ...ot switch on charging procedure Have the PERCEDOS checked immediately by an electrician Reset operating hours meter The operating hours meter can be manually reset in inactive operating status For thi...

Page 10: ...NTC resistance optional External temperature observation NTC resistance in power supply plug Vehicle communication Integrated communication modul PWM according IEC 61851 Data port short circuit proof...

Page 11: ...green periodic self test has activated Operating hours exceeded Current indicator 1 Displays illuminates when the vehicle is being actively charged Otherwise no display off 2 Illuminates green momenta...

Page 12: ...l vertrieb kopp euKopp Austria GmbH Theodor Simoneit Stra e 2 A 4160 Aigen Tel 43 7281 6566 0 Fax 43 7281 8790 Technische Beschreibungen Abbildungen und Leistungsangaben stellen keine zugesagten Eigen...

Reviews: