Instruction Manual PERCEDOS

®

Function description:

PERCEDOS

®

 is a portable protective system (IC-RCD*) including communication 

interface to the electrical vehicle and intended for use on the charging cable in 

mode 2. The device checks the power supply for proper function and only allows 

current to be drawn from a safe power source. 

The charger of the electrical vehicle controls the charging procedure of the bat-

teries and prompts the PERCEDOS

®

 to switch the charging procedure on or off 

by means of the communication connection. In order to activate the charging 

procedure, the PERCEDOS

®

 must be activated. An inactive PERCEDOS

®

 status 

is the equivalent of a standby function. Without PERCEDOS

®

, it is impossible to 

charge the vehicle in mode 2.

When  connected  to  an  outlet,  the  device  automatically  recognizes  whether 

mains voltage is present at the feed point. It is not necessary to manually switch 

on the PERCEDOS

®

 

If  mains  voltage  is  recognized,  the  device  automatically  starts  the  protective 

ground monitoring. This monitoring function is constantly active as long as the 

device is operated with mains voltage and monitors the protective ground con-

nection between PERCEDOS

®

 and the outlet for the presence of the protective 

ground wire and its freedom from faults.

So that the PERCEDOS

®

 can detect external voltage on the protective ground, 

the  device  must  be  connected  to  the  electrical vehicle. The  function  external 

voltage detection is also automatically activated as soon as the plug connection 

to the vehicle has been created and detected.

As soon as the PERCEDOS

®

 finds one of these faults, the charging procedure is 

immediately interrupted  or a beginning of the charging procedure is prevented

The fault current circuit breaker integrated into the device additionally protects 

the user against an electrical accident in case of a system defect.

Sequence of the charging procedure:

1.  Check the maximum possible charging current of the outlet and reparame-

terize the charging current of the PERCEDOS

®

 after connection to the mains 

voltage, if necessary.

2.  Connect PERCEDOS

®

 to outlet (mains voltage) and to vehicle.

3.  PERCEDOS

®

 automatically starts its test sequence; (outlet and connection 

cables) are checked for proper function.

4.  After the test sequence and if no malfunctions have been determined, the 

PERCEDOS

®

 is ready to activate the charging procedure.

5.  For this, the PERCEDOS

®

 must be activated in operating status.

6.  Check operating status and switch to active if necessary

7.  The charging current of the PERCEDOS

®

 may need to be reparameterized.

8.  The vehicle electronics switch the PERCEDOS

®

 on and off for the charging 

procedure.

* IC-RCD = In Cable - Residual Current Device

Summary of Contents for PERCEDOS

Page 1: ...PERCEDOS by PERCEDOS by Instruction Manual Technical Information...

Page 2: ...d wire and its freedom from faults So that the PERCEDOS can detect external voltage on the protective ground the device must be connected to the electrical vehicle The function external voltage detect...

Page 3: ...otective ground wire is activated PERCEDOS only attached to the vehicle Device is not being supplied with mains voltage device off No visual feedback possible No protective ground monitoring possible...

Page 4: ...reen Battery charging procedure Only possible if the PERCEDOS has not detected any fault and is acti vated Standby Vehicle connection has been detected Charging procedure possible but not yet switched...

Page 5: ...splay PERCEDOS blinks green Then press button 0 and button I simultaneously and keep pressed for approx 5 seconds During initial parameterization delivered status all of the LED s of the current indic...

Page 6: ...ing procedure is permanently switched off if the excessive tempe rature continues to be measured when the lowest charging level of 6A is reached Display PERCEDOS illuminates red Display vehicle and cu...

Page 7: ...allo wed after it is switched off for the fourth time permanent switch off Display PERCEDOS illuminates red Display vehicle and current indicators are off Manual test of the differential fault current...

Page 8: ...fault current function and an operating hours meter monitors the maximum recommended operating time until the next retesting Periodic self test The PERCEDOS checks the differential fault current funct...

Page 9: ...ot switch on charging procedure Have the PERCEDOS checked immediately by an electrician Reset operating hours meter The operating hours meter can be manually reset in inactive operating status For thi...

Page 10: ...NTC resistance optional External temperature observation NTC resistance in power supply plug Vehicle communication Integrated communication modul PWM according IEC 61851 Data port short circuit proof...

Page 11: ...green periodic self test has activated Operating hours exceeded Current indicator 1 Displays illuminates when the vehicle is being actively charged Otherwise no display off 2 Illuminates green momenta...

Page 12: ...l vertrieb kopp euKopp Austria GmbH Theodor Simoneit Stra e 2 A 4160 Aigen Tel 43 7281 6566 0 Fax 43 7281 8790 Technische Beschreibungen Abbildungen und Leistungsangaben stellen keine zugesagten Eigen...

Reviews: