21
1
2
3
4
5
7
1. Left lock
2. Sealing strip
3. Packer arm
4. Right lock
5. Left the unlock
button
6. Sealing strip
7. Plastic bags limit line
8. Plastic stop line
9. Heat tape
10. Right the unlock
button
11. Pumping air outlet
The internal control panel
6
8
9
10 11
ATTENTION:
THE HEATING BAR REACHES HIGH TEMPERATURES
PRODUCT FUNCTION DESCRIPTION
Key operation:
1. Press the green flag key: start ventilation function and bag sealing
function.
2. Press the Red Flag Key: start the sealing function.
3. Press the gray Flag Key: close all functions, enter the standby mode.
LED light:
1. Green light for the ventilation function.
2. Red light for sealing bag function.
WARNING!
HOT SURFACE