background image

II. Incoming Inspection

Kooltronic Heat Exchangers are designed, built, and packaged to withstand the shock and vibration normally
associated with shipment by common carriers. Occasionally improper handling during shipping causes damage.
Such handling could include unbanding of palletized shipments, failing to respect any carton handling
instructions, falling off conveyors, excessive vibration, crushing, etc. Therefore, a thorough inspection should be
done upon receipt of all shipments. Any carton tears, dents, scratches, or loose articles should be noted on the
Freight Bill. Cartons should be opened promptly and the units inspected for CONCEALED DAMAGE.

An immediate claim MUST be filed with the freight carrier and an inspection requested. Retain all packing
materials. Kooltronic cannot assume responsibility for Consignee’s failure to file a timely freight claim.

III. Product Handling

Do not attempt to operate your Kooltronic Heat Exchanger until you read and thoroughly 
understand this Manual.

Before operating this unit, all electrical wiring must be checked to assure the proper connections.

IV. Product Identification and Nameplate

Model Number

Serial Number

Electrical power characteristics

Maximum enclosure temperature

Filter Part Number

We recommend you copy this information 
from your unit.

3

CAUTION

Operate this unit only on the proper voltages and frequencies as 

noted on the nameplate.

MODEL NO.

SERIAL NO.

MAX. CABINET

VOLTS.

FREQ.

PH.

AMPS

TEMP. 

o

F

MAX.

FILTER P/N

FUSE SIZE

UNAUTHORIZED SERVICE OR MODIFICATION VIOLATES WARRANTY

ALL MOTORS ARE THERMALLY PROTECTED

THIS PRODUCT IS PROTECTED BY ONE OR MORE OF THE FOLLOWING
PATENTS: 3,019,965  3,120,166  3,211,360  3,559,728  3,807,493  AND 
OTHER PATENTS PENDING

MANUFACTURED BY:

KOOLTRONIC, INC.  PENNINGTON, NJ

Heat Exchanger

     

When ordering parts, specify the
Model Number and Serial Number.

Make sure that these parameters are
met. Failure to do so may result in
permanent damage to the unit.

Before operating, be sure that the
power source matches these
requirements.

  

Each Kooltronic Heat Exchanger includes an identification nameplate. This nameplate provides:

Summary of Contents for KXRP28

Page 1: ...S HEAT EXCHANGER IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com 900 046 18 7 19 CDR 20178 Find additional information on this model at kooltronic com or use the Technical Documents QR code below Technical Documents ...

Page 2: ...nic Advantage Heat Exchangers are designed for outdoor and indoor applications with ambient temperature from 20 F to 131 F and maximum allowable enclosure temperature of 160 F These heat exchangers utilize a counterflow airstream for maximum heat transfer efficiency in a closed loop system providing cooling within sealed electronic cabinets This Manual provides you with the necessary general infor...

Page 3: ...read and thoroughly understand this Manual Before operating this unit all electrical wiring must be checked to assure the proper connections IV Product Identification and Nameplate Model Number Serial Number Electrical power characteristics Maximum enclosure temperature Filter Part Number We recommend you copy this information from your unit 3 CAUTION Operate this unit only on the proper voltages ...

Page 4: ... above 60 F the heater thermostat shuts off the heater See wiring diagram on page 6 1 Attach the mounting bracket to the enclosure using the mounting hardware supplied by Kooltronic 2 Route the power cord through the top cut out in your enclosure Hang the unit on the mounting bracket 3 Tighten the unit s bottom flange to the enclosure using the hardware supplied by Kooltronic The main component of...

Page 5: ...e for reference only and are subject to change KXRP28 Technical Data Maximum Allowable Temperature F Approx Power Enclosure Ambient Watts F Weight Model Volts Amps Watts Max Min Max Air In lbs KXRP28 115 1 2 135 160 20 131 24 31 5 K2XRP28 230 0 7 153 160 20 131 24 31 5 60 Hz operation For 50 Hz operation consult Kooltronic Major Component Replacements Model Impeller Capacitor Filter KXRP28 0194 37...

Page 6: ...6 OPTIONAL HEATER HEATER CONTROL T STAT THERMAL CUT OUT AMBIENT BLOWER OPTIONAL CAP T STAT ENCLOSURE BLOWER CAP BLK WHT Wiring Diagram WD 830 ...

Page 7: ...ilter may be sprayed with Kooltronic A 16 Filter Recoating Adhesive to trap fine airborne contaminants or they can simply be dried and reinstalled as strainer type filters Recoating is recommended for the best results 4 Reinstall the filter in the Filter Retainer VIII Packing Procedure Keep Heat Exchanger in proper upright position Pack Heat Exchanger in an appropriate carton preferably original c...

Page 8: ...s received by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a suitable container for shipment preferably the original packaging if available All Heat Exchangers must be returned in an upright position properly secured to a pallet Improper packaging may void wa...

Reviews: