Technical Data

9

M

Rated for full capacity load at 85°F water. Usage will vary at lower load or cooler water conditions.

* Switchable. Switch is internally-mounted for security.
** Rating shown is for operation at maximum water temperature.

"

115V, 60 Hz and 230V, 60 Hz models also perform at full capacity when operated
at 100V, 50 Hz or 200V, 50 Hz respectively. No transformer is required.

**

Water Flow (GPM)  

Running

Height Series

BTU/H

@

85° F. Max.

M

Amps **

28 36 47 52 59

Model

Rating

28

36 47-59

Volts

Hz

28/36

47-59

G G

KA4C2WP _ _

2000

1.0 1.0

115/100

60/50

9.8

G G

KA4C2WP _ _/56

2000

1.0 1.0

115

50/60*

9.8

G G

K2A4C2WP _ _

2000

1.0 1.0

230/200

60/50

5.0

G G

K2A4C2WP _ _/5

2000

1.0 1.0

230

50

5.0

G G

KA4C3WP _ _

3000

1.0 1.0

115/100

60/50

9.9

G G

KA4C3WP _ _/56

3000

1.0 1.0

115

50/60*

9.9

G G

K2A4C3WP _ _

3000

1.0 1.0

230

60

5.2

G G

K2A4C3WP _ _/5

3000

1.0 1.0

230

50

5.2

G G G G G

KA4C4WP _ _

4000

1.0 1.0 1.5

115

60

10.0

12.4

G G G G G

KA4C4WP _ _/56

4000

1.0 1.0 1.5

115

50/60*

10.0

12.4

G G G G G

K2A4C4WP _ _

4000

1.0 1.0 1.5

230

60

5.4

6.2

G G G G G

K2A4C4WP _ _/5

4000

1.0 1.0 1.5

230

50

5.4

6.0

G G G G G

KA4C5WP _ _

5000

1.5 2.0 1.5

115

60

11.6

12.6

G G G G G

KA4C5WP _ _/56

5000

1.5 2.0 1.5

115

50/60*

11.6

12.6

G G G G G

K2A4C5WP _ _ 

5000

1.5 2.0 1.5

230

60

6.8

6.3

G G G G G

K2A4C5WP _ _/5

5000

1.5 2.0 1.5

230

50

5.8

6.1

G G G G G

KA4C6WP _ _

6000

1.5 2.0 1.5

115

60

11.8

12.8

G G G G G

KA4C6WP _ _/56

6000

1.5 2.0 1.5

115

50/60*

11.8

12.8

G G G G G

K2A4C6WP _ _

6000

1.5 2.0 1.5

230

60

7.0

6.4

G G G G G

K2A4C6WP _ _/5

6000

1.5 2.0 1.5

230

50

6.0

6.2

G G G G G

KA4C7WP _ _

7000

1.5 2.0 1.5

115

60

12.0

13.0

G G G G G

KA4C7WP _ _/56

7000

1.5 2.0 1.5

115

50/60*

12.0

13.0

G G G G G

K2A4C7WP _ _

7000

1.5 2.0 1.5

230

60

7.2

6.5

G G G G G

K2A4C7WP _ _/5

7000

1.5 2.0 1.5

230

50

6.2

6.3

G G G G

KA3C8WP _ _

8000

2.0 2.5

115

60

14.0

13.4

G G G G

KA3C8WP _ _/56

8000

2.0 2.5

115

50/60*

14.0

13.4

G

K2A3C8WP _ _

8000

2.0 2.5

230/200

60/50

7.3

G

K2A3C8WP _ _/5

8000

2.0 2.5

230/200

50/60*

6.2

G G G

K2A4C8WP _ _

8000

2.0 2.5

230

60

9.7

G G G

K2A4C8WP _ _/5

8000

2.0 2.5

230

50

9.2

G G G

KA3C9WP _ _

9000

2.5

115

60

13.6

G G G

KA3C9WP _ _/56

9000

2.5

115

50/60*

13.6

G G G

K2A4C9WP _ _

9000

2.5

230

60

9.8

G G G

K2A4C9WP _ _/5

9000

2.5

230

60

9.3

G G G

KA3C10WP _ _

10000

2.5

115

60

13.8

G G G

KA3C10WP _ _/56 10000

2.5

115

50/60*

13.8

G G G

K2A4C10WP _ _

10000

2.5

230

60

9.9

G G G

K2A4C10WP _ _/5 10000

2.5

230

50

9.4

G G G

KA3C12WP _ _

12000

2.5

115

60

14.0

G G G

KA3C12WP _ _/56 12000

2.5

115

50/60*

14.0

G G G

K2A4C12WP _ _

12000

2.5

230

60

10.0

G G G

K2A4C12WP _ _/5 12000

2.5

230

50

9.5

"

"

NOTE: The above units are no longer current standard products. Contact Kooltronic for information on current units.

Summary of Contents for K2A3C8WP 5 Series

Page 1: ...BEFORE INSTALLING AND USING THIS AIR CONDITIONER IT IS IMPORTANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609...

Page 2: ...ntroduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all sizes and shapes of electronics enc...

Page 3: ...e in a horizontal position only This placement must be done a minimum of 5 minutes prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operati...

Page 4: ...ber MFG Order Number e Before operating be sure that the power source matches these requirements y Use of incorrect type or amount of refrigerant will adversely affect performance and may damage the u...

Page 5: ...by means of the vapor compression refrigeration cycle This takes place in a hermetically sealed refrigeration system utilizing either an air cooled or water cooled condenser heat exchanger The warm ai...

Page 6: ...delayed until the system pressures rise 10 Operate the air conditioner for approximately ten 10 minutes During this period no unusual noise or vibration should be evident Both the evaporator and cond...

Page 7: ...upplied to the drain exit on the bottom or lower side panel of the Air Conditioner The optional field installed Condensate Evaporator is mounted underneath the Air Conditioner and the drain hose is co...

Page 8: ...STMENT D 312 DIA HOLES 7 TYP C B 19 A E 2 1 185 16 131 2 11 2 DIA POWER CORD HOLE 3 19 3 E A 7 TYP B 1 3 D 312 DIA HOLES 161 2 183 8 C L 19 COOL AIR OUTLET TO ENCLOSURE WARM AIR RETURN FROM ENCLOSURE...

Page 9: ...5 230 60 6 8 6 3 G G G G G K2A4C5WP _ _ 5 5000 1 5 2 0 1 5 230 50 5 8 6 1 G G G G G KA4C6WP _ _ 6000 1 5 2 0 1 5 115 60 11 8 12 8 G G G G G KA4C6WP _ _ 56 6000 1 5 2 0 1 5 115 50 60 11 8 12 8 G G G G...

Page 10: ...H KA4C_WP28 KA4C_WP28 8000 BTU H KA4C_WP36 KA4C_WP36 KA3C8WP36 Part Part Number Part Number Part Number Compressor 0665 101 0665 103 0665 42 Compressor Capacitor N A N A 0452 32 Condenser Coaxial Coil...

Page 11: ...Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic Air Conditioners feature an easily removable inlet f...

Page 12: ...valve fails it is strongly recommended that the Air Conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect refri...

Page 13: ...ntrol Replace Thermostat or Relay Thermostat defective when applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Appli...

Page 14: ...unted Cooled Mini NP33 Horizontal Accessories and Options HS P24 P47 NP36 Rack Top Panel MM NM P28 P52 NP47 Mounted Mounted Mounted SM NP17 P36 P59 NP59 H V HT WP Adapter Plate for Rack Mounting N A N...

Page 15: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...

Reviews: