IV. Product Identification and Nameplate

Each Kooltronic Air Conditioner includes an identification nameplate. This nameplate provides:

q

Model Number

w

Serial Number

e

Electrical power characteristics

r

Maximum and minimum ambient operating temperatures

t

Cooling capacity

y

Type and amount of refrigerant required for recharging

u

Design Pressure

i

Maximum Fuse Size

o

Manufacturing Order Number

a

Filter Part Number

s

Underwriters Laboratories Inc. Listed or Recognized Marks and NEMA ratings

We recommend you copy this information from your unit.

qwo

When ordering parts, specify the Model Number, Serial Number & MFG. Order Number.

e

Before operating, be sure that the power source matches these requirements.

y

Use of incorrect type or amount of refrigerant will adversely affect performance and may damage the unit.

Make sure that these parameters are met. Failure to do so may result in permanent damage to the unit.

ALL MOTORS ARE THERMALLY PROTECTED

VIOLATES WARRANTY

UNAUTHORIZED SERVICE OR MODIFICATION

SERVICE AIR FILTER REGULARLY

OUTDOOR USE

COMPARTMENT ONLY

NEMA/EEMAC/UL50 BY UNDERWRITERS LABORATORIES, INC.

TYPE 1 SPECIAL PURPOSE AIR CONDITIONER EQUIPMENT

TYPE 3R & 12 INTERFACE TO THE ELECTRICAL ENCLOSURE ONLY

NEMA/EEMAC/UL50 BY UNDERWRITERS LABORATORIES, INC.

SPECIAL PURPOSE AIR CONDITIONER

FILTER P/N

FUSE SIZE

MAX.

HIGH

LOW

Oz.

REFRIGERANT

MAX.°F

MIN.°F

AMBIENT TEMP.

COOLING

ALLOW 5 MIN. BEFORE RESTARTING AFTER SHUTDOWN

Air Conditioner

DESIGN PRESSURE P.S.I.G.

MFG. ORDER NO.

KOOLTRONIC, INC.   PENNINGTON, NJ

MANUFACTURED BY:

COOLING BTU

F.L.A.

PH.

FREQ.

VOLTS

SERIAL NUMBER

MODEL NUMBER

e

e

e

e

r

r

t

y

q

w

u

u

i

a

o

s

Summary of Contents for Advantage RP55 Series

Page 1: ...TANT THAT THIS MANUAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com 900 039 38 2 19 CDR 20131 ADVANT...

Page 2: ...tion Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all sizes and shapes of electronic enclosures...

Page 3: ...e in a horizontal position only This placement must be done a minimum of 5 minutes prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operati...

Page 4: ...Use of incorrect type or amount of refrigerant will adversely affect performance and may damage the unit r Make sure that these parameters are met Failure to do so may result in permanent damage to t...

Page 5: ...hen passed through the condenser coil where it absorbs the heat and is then discharged to the environment The unit is equipped with a Bypass Thermostat to prevent the evaporator coil from freezing and...

Page 6: ...r respective discharge ports The cool air discharged should be less than 70 F when the room temperature is between 70 F and 80 F 10 Turn off the electrical power and disconnect the air conditioner fro...

Page 7: ...e front panel on the hooks of the M TAB Using the two hooks on each side of the M TAB as a guide be sure that the air conditioner is absolutely parallel to the M TAB We recommend using a lift truck fo...

Page 8: ...1 25 31 7 0 74 18 7 19 25 488 9 1 00 31 44 798 5 10 00 1 36 34 5 18 00 457 2 25 4 53 35 1355 0 20 64 524 2 7 31 185 6 TYP LEFT FRONT RIGHT REAR BOTTOM TOP 254 0 10 00 254 0 0 69 17 5 6 00 15 2 21 99...

Page 9: ...P55R Part Part Number Compressor 0665 78 Compressor Capacitor 0452 61 Condenser Blower Motor 0261 138 Condenser Blower Capacitor 0452 44 Evaporator Blower Motor 0261 288 Evaporator Blower Capacitor 04...

Page 10: ...OTOR CAP BK WE CRANKCASE HEATER PRESSURE SWITCH N O COOLING EFFECT DETECTOR TERMINAL BLOCK TO CUSTOMER ALARM SYSTEM RELAY 1 R CONTROL Y B T STAT HEATER HEATER B C T STAT CUT OUT THERMAL TRANSFORMER DI...

Page 11: ...operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic Air Conditioners feature an easily removable inlet filter to fa...

Page 12: ...ss valve fails it is strongly recommended that the air conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect ref...

Page 13: ...applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Application Failed Evaporator Blower Replace Evaporator Blower Mo...

Page 14: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...

Reviews: