1. 

Check  if  the  ice  machine  is  in  good 
condition  and  the  accessories  are 
complete;  check  the  machine  model  and 
the machine nameplate. 

2. 

Clean the ice bin and the food area inside 
with a sponge soaked in warm water and 
soap. Then  wash  and  dry  it  with  potable 
water. 

3. 

Place  the  ice  machine  in  the  operation 
area; ensure that the machine is placed on 
a leveled floor. So as to ensure the water 
flows evenly on the evaporator. 

4. 

The compressor chamber is located at the 
back. The compressor and condenser are 
installed in it. For air cooled unit, it requires 
good ventilation. Therefore, the front and 
rear of the ice maker must have ventilation 
space of more than space of more than 8” 
in the rear, 6” on the sides, and 12” in the 
front 

5. 

The bottom of the ice machine is equipped 
with  adjustable  legs  for  level  adjustment 
and floor cleaning. 

6. 

Connect  the  machine's  inlet  water  filter 
and water pipe referring to the

 

schematic 

diagram  of  installation;  if  the  installation 
site  is  already  equipped  with  a  drinking 
water system, the water filter may not be 
installed. 

 Note: the filter flow direction should be 

correctly  installed  as  per  the  direction 
marker on the filter head cover or the filter 

body. 

 Note: This machine is equipped with an 

inlet  water  filter.  The  filter  will  keep 
impurities  from  the  water  used  as  the 
machine is running. Generally, it needs to 
be  replaced  every  month  to  every  3 
months. 

7. 

Connect the machine to the water supply 
using the 3/4" inlet pipe supplied with the 
machine.  It  is  recommended  to  install  a 
water  valve  (not  supplied  with  this 
machine) on the water supply line. 

8. 

Connect  the  drain  pipe  to  the  drain 
connection.  In  order  to  meet  a  good 
draining, it is recommended that the drain 
pipe  should  have  a  difference  of  level 
more than 1” per 3’; and confirm that the 
drain  pipe  is  not  blocked.  It  is 
recommended  that  the  drain  pipe  be 
connected to an open drainage port. 

9. 

Any  joint  in  the  drain  pipe  must  not  be 
higher  than  the  machine  drainage  port; 
any joint in the drain pipe cannot be higher 
than the previous joint. 

10. 

Confirm the power requirements stated in 
the  machine  nameplate;  ensure  that  the 
power supply meets the requirements. 

11. 

A  circuit  breaker  or  switch  with  leakage 
protector  and  reliably  grounding  is 
required. 

12. 

Turn off the switch on the power line and 
connect the machine to the power source. 

Startup and Operation

 

1. 

Before  you  start  up  the  machine,  please 
check and confirm: 

 

That  the  packaging  tape  inside  the  ice 
machine has been removed;

 

 

The  accessories  or  items  in  the  ice  bin 
have been taken out;

 

 

The  ice machine has been  adjusted to a 
leveled state;

 

 

The  water  pipe has been  connected and 
the water valve is open;

 

 

The plug has been connected to the power 
supply and the power switch is off.

 

 

The 

ambient 

temperature, 

water 

temperature,  and  pressure  of  the  water 
supply meet the above requirements.

 

2. 

Start  up:  turn  on  the  power  switch. After 
power-on, the machine begins to make ice 

Summary of Contents for CIM-350

Page 1: ...Commercial Undercounter Ice Maker User Manual for Installation and Maintenance Model CIM 350...

Page 2: ...n for Installation 5 Schematic Diagram of Installation 5 Installation Steps 6 Startup and Operation 6 Operation Instruction 7 Instruction of Control Panel 8 Maintenance 9 Service Call 10 Common Faults...

Page 3: ...f electric shock The label indicates a hazardous voltage There is a risk of electric shock The label indicates rotating components inside There is a risk of serious mechanical injury The label indicat...

Page 4: ...Instruction of symbols in this Manual Warning sign special attention is required Warning sign special attention is required and operation is prohibited...

Page 5: ...e placed on the floor sufficient to supports its weight Insufficient base may cause the equipment fall over and cause injury There should be sufficient ventilation space around the ice machine Keep go...

Page 6: ...ar non retail occasions This ice machine is not intended for residential use Installation Location for Installation The ice machine should be installed in a proper location meeting the following condi...

Page 7: ...Modular Ice Maker User Manual for Installation and Maintenance Schematic Diagram of Installation...

Page 8: ...s running Generally it needs to be replaced every month to every 3 months 7 Connect the machine to the water supply using the 3 4 inlet pipe supplied with the machine It is recommended to install a wa...

Page 9: ...onnect the power and water source Self check with power on for the first time the ice maker will do self check and pump out remaining water Preparing after the ice machine is energized the inlet valve...

Page 10: ...tended or shortened by 1 5 minutes 4 Cleaning During the normal operation hold the cleaning button for 3 seconds to enter the cleaning process During the entire cleaning process cleaning agents and di...

Page 11: ...nvironment around the ice machine to keep it clean Do not block the vents The outer enclosure should be cleaned with a mild detergent and then wiped clean If necessary use commercial stainless steel c...

Page 12: ...nished the led display flashes Clean slowly again Put in proper amount of sanitizer manually followed by the clean and sterilizing process instruction Push the clean button again the ice maker will do...

Page 13: ...machine and record the model and series number of the ice machine Note If the machine fails due to the user s faults such as no supply of water electricity or environmental factors rather than the fau...

Page 14: ...incomplete Ice thickness too thin Water pressure too low Water temperature too high Inlet water valve does not work Inlet water valve is dirty and blocked Water leaking Inlet water filter has not bee...

Page 15: ...y Koolmore This includes but is not limited to residential outdoor or mobile applications Any adjustments necessitated by improper operating conditions Improper water pressure or temperature or failur...

Page 16: ...arranty is only valid on equipment purchased from an authorized dealer Locate the model number on the rating label Next call 1 718 576 6342 You must have the model number when contacting service techn...

Page 17: ......

Reviews: