The fault code and its comments are displayed as follows:
Code
Error
Machine status
E01
Water Curtain failure or Ice Full
Switch
Sleeping mode will recover after
the water curtain is reset
E03
Ice Harvest Overtime
Protective shutdown
E04
High Temperature
Protective shutdown
E05
Water Shortage Fault
Protective shutdown and retry
every 30 mins
E06
High Pressure
Protective shutdown
E07
Contestation Sensor Open
Circuit
Error light comes on every 5
seconds
E08
Condensation Sensor Short
Circuit
Error light comes on every 5
seconds
E13
Water Level Control failure
Protective shutdown
Maintenance
Note: Maintenance must be done by a
qualified professional personal.
Warning: Before maintenance or manual
clean, be sure to cut off the water source
and power supply.
Exterior cleaning
Frequently clean the environment around the
ice machine to keep it clean. Do not block the
vents.
The outer enclosure should be cleaned with
a mild detergent and then wiped clean. If
necessary, use commercial stainless steel
cleaners and polishes.
Note: Stainless steel may rust without
proper maintenance.
Inlet water filter
The filter element should be inspected
regularly. It is recommended to replace filter
element every month to every 3 to 6 months.
Interior cleaning
The inside of the ice storage bin can be
washed with water and solution.
Note: Check and confirm the water
pressure lower than the maximum allowed
pressure. Do not flush the part above the
water pump or the evaporator directly for
water protection.
Condenser
For the air-cooled ice maker, the condenser
should be cleaned every three weeks. Use a
soft brush or a vacuum cleaner with a brush
to brush it up and down along the fin
direction, to avoid damage to the fins and
further affecting the cooling effect.
The condenser filter should be cleaned every
2 weeks.