![Koolaire KDT0300A Technician'S Handbook Download Page 60](http://html1.mh-extra.com/html/koolaire/kdt0300a/kdt0300a_technicians-handbook_1996841060.webp)
60
Part Number STH063 9/17
Determining Which Safety Limit Stopped the Ice Machine:
1. Cycle the toggle switch Off.
2. Cycle the toggle switch On to start ice making.
3. Watch the safety limit lights.
• One will flash corresponding to safety limits 1 or 2.
4. Safety limit 3 is indicated by both SL#1 & SL#2
flashing.
After safety limit indication, the ice machine will restart
and run until a safety limit is exceeded again.
Safety Limit Notes
• A continuous run of 100 harvests automatically erases
the safety limit code.
• The control board will store and indicate only one
safety limit – the last one exceeded.
• If the toggle switch is cycled OFF and then ON prior
to reaching the 100-harvest point, the last safety limit
exceeded will be indicated.