Part Number STH063 9/17
33
Operational Checks
ICE THICKNESS CHECK
After a harvest cycle, inspect the ice cubes in the ice
storage bin. The ice bridge connects the ice cubes and
must be set to maintain an ice bridge thickness of 1/8"
(3 mm). To adjust the thickness of the bridge refer to ice
thickness adjustment.
The ice thickness float switch is factory-set to maintain the
ice bridge thickness at 1/8" (3 mm).
NOTE: Make sure the water curtain is in place when
performing this check. It prevents water from splashing out
of the water trough.
1. Inspect the bridge connecting the cubes. It should be
about 1/8" (3 mm) thick.
2. If adjustment is necessary, turn the ice thickness
float switch clockwise to increase bridge thickness,
counterclockwise to decrease bridge thickness. Adjust
to achieve a 1/8" (3 mm) bridge thickness.
NOTE: The float can be adjusted with a 3/4" wrench while
the water trough is in-place. Test run two cycles to verify
ice bridge thickness.
Ice Thickness Float
Switch Adjustment