BAKL481602A 

Edition: 01.03.2017 

Page: 9/11 

 

Switch over Function MODE: 

2 x 

 

Switch from Function Mode = AUTO - HEAT - COOL - AUTO button on the dou-

ble. 

Function Mode 

System heating 

System ventilation 

System cooling 

AUTO 

HEAT 

-- 

COOL 

-- 

Switch Display: 

2 x 

  

Switch the display of clock - room temperature - Outdoor temperature time. 

Check air duct temperature: 

5sec + 

  

Switch from the display for 5 seconds on channel temperature. 

Check FB temperature: 

  

Switch from the display for 5 seconds on driver temperature. 

Enable keyboard lock: 

10sec. 

  

Key lock is enabled, the display stands and "Loc". Manual 

fan cabin and set temperature setting is disabled. 

Check hours of operation 

  When ignition is OFF by pressing the keys the operating hour counters are 

called. 

1

 = operating hours unit; 

2

 = operating hours compressor / 

Note: h

 = hours, 

d

 = days, 

Y

= year 

4.  Maintenance 

Please arrange regular dates for maintenance works and services with a KONVEKTA service sta-
tion, as indicated in maintenance schedule bus no.: 

WP07050618.

On our website 

www.konvekta.com

 in category 

>service<

 you will find a survey of contact details of all our service 

partners close to your location. 

- Only qualified staff is allowed to carry out these works! - 

For general instructions on repair – and maintenance works please contact via email: 

[email protected]

 

 

Danger of accidents!

 

Qualified staff in charge of installation and maintenance have to be trained in accordance with EN 
378-Part 4 and (EC) No.307/2008 and must strictly follow the legal provisions. 
Any works or modifications at the air conditioner which are carried out improperly can lead to mal-
function and so endanger operational reliability. We recommend having all works and modifications 
carried out at an authorized KONVEKTA Service Station.  
Before carrying out any maintenance works at your air conditioning unit, carefully read the  
KONVKETA safety provisions (TD00052A)

 

in order to avoid any dangers and accidents! 

Summary of Contents for KL47T

Page 1: ...adt Germany 49 0 66 91 76 0 49 0 66 91 76 200 Info konvekta com www konvekta com Operating Instruction for KONVEKTA air conditioning unit KL47T KL48T KL49T with control KS600 CAN Version 24 Volt DC Frischluft Heizung ID BBA KL481602A Version A02 ...

Page 2: ...t 5 1 2 Intended use 6 1 3 Operating conditions 6 3 Operation 6 1 4 Operation panel function of the keys 6 1 5 Special functions of the KS600 8 4 Maintenance 9 1 6 Compressor type KVX 10 1 7 Return air grid 10 1 8 Condenser coil 10 1 9 Troubleshooting 10 5 Warranty Conditions 10 6 Waste disposal in accordance with legal provisions 11 7 History of modification 11 Appendix Maintenance Schedule Bus W...

Page 3: ...ncreases operation reliability and service life of the air conditioning unit and reduces life cycle costs Please complete these instructions by adding the national provisions for prevention of accidents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any w...

Page 4: ... is equipped with details not shown or described in the operating in struction your KONVEKTA Service Station will always be at disposal for informing you about correct operation In the course of further developments we reserve the right to technical modifications without preno tice Guarantee and liability conditions of KONVEKTA AG s general business conditions are not enlarged by the above notes I...

Page 5: ...rand quantity liter Esteröl SE55 2 liter Magnetic clutch 1 weight approx kg 12 24V DC 12 kg 1 ø depending on vehicle type 2 Generally information for a c unit Attention in case of roof top a c units Never switch on the a c unit during car wash The a c unit is operational with running engine only At cooling operation the humidity inside the vehicle is decreased which avoids steamed up windows The a...

Page 6: ...sion nor for consequential damage resulting there from nor for damages caused by cleaning the systems with highly compressed or corrosion advancing substances 3 Operation Danger of accidents Focussing your attention on the road traffic is of top priority Only operate your air conditioning unit when the traffic situation allows it Make sure you can clearly recognize and read all operation and displ...

Page 7: ...eat to recirculation Long press Double click Key combination Keypress Functional description Short press Turns ECO AUTO without compressor ON and OFF Long press Double click Key combination Keypress Functional description Short press Turns Automatic ON and OFF Long press Can be switched between AUTO HEAT COOL Double click Key combination You get into the service modus Ignition OFF Querying the err...

Page 8: ...teps Long press Double click Key combination Keypress Functional description Short press Reducing the room set temperature for the passenger compart ment After reaching the minimum Temperature 6 x press key MAX COOL Long press Double click Key combination Keypress Functional description Short press Switches the auxiliary heater ON Long press Double click Key combination Ignition OFF Preheater star...

Page 9: ...r dates for maintenance works and services with a KONVEKTA service sta tion as indicated in maintenance schedule bus no WP07050618 On our website www konvekta com in category service you will find a survey of contact details of all our service partners close to your location Only qualified staff is allowed to carry out these works For general instructions on repair and maintenance works please con...

Page 10: ...efective check electric connections at switchboard defrost thermostat has switched off check relay replace if necessary outside temperature too low possible icing of evaporator check evaporator blower replace if necessary evaporator coil dirty switch on ventilation only compressor does not compress clean evaporator coil with compressed air excess pressure pressure too high check pressure at suctio...

Page 11: ...ation of road prescriptions Resolution EC No 2037 2000 of the Euro pean Parliament and of the Council for ma terials that affect the ozone layer Resolution to prohibit certain ozone destroy ing halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulations are to be followed Only qualified staff is allowed to carry out...

Reviews: