background image

 

 

BAKL481602A 

Edition: 01.03.2017 

Page: 10/11 

 

1.6.  Compressor type KVX 

Make  the  first  oil  change  at  the  first  maintenance  of  the  vehicle.  Then  approx.  every  3  years.  At 
every oil change the oil  suction strainer has to be cleaned. Observe the oil quantity according to 
the compressor type (see chapter: 

1.1

). 

1.7.  Return air grid 

Clean the return air grid in the passenger area 

monthly

in case of enormous dirt weekly

1.8.  Condenser coil 

Always keep condenser coil fins clean. Severe soiling cause’s excess pressure within the a/c-unit 
system and it automatically stops working

.

 

 

Attention:

 

The condenser coil fins have to be cleaned with compressed air at least once a 

year, in case of severe soiling more often. 

1.9.  Troubleshooting 

 

 Only qualified staff is allowed to carry out these works! 

Trouble 

Cause 

Repair  

only by refrigeration expert

 

1

 

a/c is not run-
ning 

magnetic clutch does not switch 
on 

  check inside temperature 

2

 

electric connections disconnect-
ed 

  check connections at magnetic clutch 

relay defective 

  check electric connections at switchboard 

defrost thermostat has switched 
off 

  check relay, replace if necessary 

outside temperature too low 
(possible icing of evaporator) 

  check evaporator blower, replace if necessary 

evaporator coil dirty 

  switch on "ventilation" only 

compressor does not compress 

  clean evaporator coil with compressed air 

excess pressure (pressure too 
high) 

  check pressure at suction and discharge side, 

replace compressor if necessary 

excess pressure caused by high 
outside temperature 

  check axial fans  

leakage in a/c unit, lack of re-
frigerant 

  check fuses at switchboard 

low pressure, dryer clogged 

  clean condenser coil with compressed air 

screen of expansion valve 
clogged 

  run unit until pressure has stabilized

2

 

Loud noise at 
compressor 

defective bearing at compressor 

  check a/c unit for leakages  

slack V-belt 

  check V-belt at compressor drive 

 

On our website www.konvekta.com in category >service< you will find a survey of contact details of all our service 

partners close to your location

.

 

 

By user 

5.  Warranty Conditions 

The current „General Warranty Conditions KONVEKTA AG“ will apply. A copy will be furnished by 
the warranty department. Please contact: 

[email protected]

Summary of Contents for KL47T

Page 1: ...adt Germany 49 0 66 91 76 0 49 0 66 91 76 200 Info konvekta com www konvekta com Operating Instruction for KONVEKTA air conditioning unit KL47T KL48T KL49T with control KS600 CAN Version 24 Volt DC Frischluft Heizung ID BBA KL481602A Version A02 ...

Page 2: ...t 5 1 2 Intended use 6 1 3 Operating conditions 6 3 Operation 6 1 4 Operation panel function of the keys 6 1 5 Special functions of the KS600 8 4 Maintenance 9 1 6 Compressor type KVX 10 1 7 Return air grid 10 1 8 Condenser coil 10 1 9 Troubleshooting 10 5 Warranty Conditions 10 6 Waste disposal in accordance with legal provisions 11 7 History of modification 11 Appendix Maintenance Schedule Bus W...

Page 3: ...ncreases operation reliability and service life of the air conditioning unit and reduces life cycle costs Please complete these instructions by adding the national provisions for prevention of accidents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any w...

Page 4: ... is equipped with details not shown or described in the operating in struction your KONVEKTA Service Station will always be at disposal for informing you about correct operation In the course of further developments we reserve the right to technical modifications without preno tice Guarantee and liability conditions of KONVEKTA AG s general business conditions are not enlarged by the above notes I...

Page 5: ...rand quantity liter Esteröl SE55 2 liter Magnetic clutch 1 weight approx kg 12 24V DC 12 kg 1 ø depending on vehicle type 2 Generally information for a c unit Attention in case of roof top a c units Never switch on the a c unit during car wash The a c unit is operational with running engine only At cooling operation the humidity inside the vehicle is decreased which avoids steamed up windows The a...

Page 6: ...sion nor for consequential damage resulting there from nor for damages caused by cleaning the systems with highly compressed or corrosion advancing substances 3 Operation Danger of accidents Focussing your attention on the road traffic is of top priority Only operate your air conditioning unit when the traffic situation allows it Make sure you can clearly recognize and read all operation and displ...

Page 7: ...eat to recirculation Long press Double click Key combination Keypress Functional description Short press Turns ECO AUTO without compressor ON and OFF Long press Double click Key combination Keypress Functional description Short press Turns Automatic ON and OFF Long press Can be switched between AUTO HEAT COOL Double click Key combination You get into the service modus Ignition OFF Querying the err...

Page 8: ...teps Long press Double click Key combination Keypress Functional description Short press Reducing the room set temperature for the passenger compart ment After reaching the minimum Temperature 6 x press key MAX COOL Long press Double click Key combination Keypress Functional description Short press Switches the auxiliary heater ON Long press Double click Key combination Ignition OFF Preheater star...

Page 9: ...r dates for maintenance works and services with a KONVEKTA service sta tion as indicated in maintenance schedule bus no WP07050618 On our website www konvekta com in category service you will find a survey of contact details of all our service partners close to your location Only qualified staff is allowed to carry out these works For general instructions on repair and maintenance works please con...

Page 10: ...efective check electric connections at switchboard defrost thermostat has switched off check relay replace if necessary outside temperature too low possible icing of evaporator check evaporator blower replace if necessary evaporator coil dirty switch on ventilation only compressor does not compress clean evaporator coil with compressed air excess pressure pressure too high check pressure at suctio...

Page 11: ...ation of road prescriptions Resolution EC No 2037 2000 of the Euro pean Parliament and of the Council for ma terials that affect the ozone layer Resolution to prohibit certain ozone destroy ing halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulations are to be followed Only qualified staff is allowed to carry out...