KONVEKTA KL30 Operating Instruction Download Page 3

 

 
BAKL30T12AD 

Edition: 28.02.2017

 

Page: 3/14

 

 

Introduction 

These  operating  instructions  have  been  written  for  drivers,  operators  and  the

 

maintenance  staff  of 

your air conditioning

 

unit. 

In this context, we refer implicitly to the compliance with our general installation guidelines. 
These 

can 

be 

obtained 

from 

the 

KONVEKTA 

technical 

after 

sales 

service: 

[email protected]

 

Please observe our valid safety instructions, available under

 

www.konvekta.de/asv.html

In 

case of order placement or any other conclusion of contract the safety instructions get inte-
gral part of the contract. 

 

These operating instructions have

 

to be read carefully and made use of before the first start-up and 

after that regularly by each person who is involved in handling the machine: 

 

  Operation including troubleshooting

 

and waste disposal

 

of fuels and auxiliary agents. 

  Servicing, inspection, repair. 

  Transport.

 

 

This  facilitates  the  handling  and  avoids  trouble  caused  by  improper  operation.  Working  in  compli-
ance with these operating instructions increases operation reliability and service life of the air condi-
tioning unit and reduces life cycle costs. 

Please complete these instructions by adding the national provisions for 
prevention of accidents and environmental protection. 

These instructions are part of the air conditioning

 

unit. 

Always

 

have a copy at hand in the driver’s cabin. 

You will certainly understand that we will not recognize any warranty claims due to improper 
handling, inadequate maintenance, applications that do not correspond with the determined 
use, utilization of non-admitted fuels or the non-observance of safety provisions. 
KONVEKTA will annul without notice all obligations concerning guarantee, service contracts 
etc. regardless if granted by KONVEKTA or its distributors in case other than original KON-
VEKTA spare parts or parts bought from KONVEKTA AG have been used for maintenance 
and repair. 

These  operating  instructions 

contain all necessary  information to operate your 

air  conditioning

 

unit

. In case you need more explanations please contact the next KONVEKTA service sta-

tion . 

 

On our website www.konvekta.com in category >service< you will find a survey of contact details of all our 

service partners close to your location. 

Summary of Contents for KL30

Page 1: ...t Germany 49 0 66 91 76 0 49 0 66 91 76 200 Info konvekta com www konvekta com Operating Instruction for KONVEKTA Air Conditioning unit KL30 KL30T with control KS50 Versions 12 respectively 24 Volt DC Fresh Air Heating ID BBA KL30T12AD Version A02 ...

Page 2: ...ning unit 8 5 3 Switch off air conditioning unit 8 5 4 Setting of the desired temperature 8 5 5 Manual adjustment of the blowers 9 5 6 ECON operation 9 5 7 Fresh and recirculating air operation 10 5 8 Demisting operation 10 5 9 Changeover temperature display mode 11 5 10 Switch the temperature indication to Fahrenheit 12 6 Maintenance Service 12 6 1 Compressor 12 6 2 Return air grid 12 6 3 Condens...

Page 3: ...increases operation reliability and service life of the air condi tioning unit and reduces life cycle costs Please complete these instructions by adding the national provisions for prevention of accidents and environmental protection These instructions are part of the air conditioning unit Always have a copy at hand in the driver s cabin You will certainly understand that we will not recognize any...

Page 4: ...se your product is equipped with details not shown or described in the operating in struction your KONVEKTA Service Station will always be at disposal for informing you about correct operation In the course of further developments we reserve the right to technical modifications without notice Guarantee and liability conditions of KONVEKTA AG s general business conditions are not enlarged by the ab...

Page 5: ...aft seal of the compressor The compressor should be started every 4 weeks for approx 15 minutes This also applies when the vehicle is not into operation for a longer period or when the air condition ing unit is not used Compressor Type SD7H15 Weight kg approx 7 5 Oil brand quantity liter PAG depend ing on version3 Magnetic clutch 2 24V DC Attention for SD7H15 Only clockwise rotation 1 Weight witho...

Page 6: ...NOTE KONVEKTA uses components made of copper and aluminium which last a whole unit life time under normal environmental conditions Should the units be operated under aggressive envi ronmental conditions i e air containing salt phosphate or ammoniac extremely a corrosion of the cupper and aluminium components can not be ruled out The cupper and aluminium components of the KONVEKTA systems are not s...

Page 7: ...Please note that the control panel keys have not been designed for heavy stressing Excessive or fast pressing of the keys for adjusting the set temperature does not accelerate the cooling down process It possibly damages the control panel and so affects the general perfor mance of the air conditioning unit 5 1 Description of the display LCD symbols Symbol Acceptation of the display symbols 1 Ambie...

Page 8: ...ars here 20286 hours Now the A C is ready for operation The last stored setting is displayed 5 3 Switch off air conditioning unit By pressing the key Blowers Minus 2 longer than 2 seconds the A C is switched off While the key is pressed the display changes temporarily This is no fault no settings are changed Press and hold Now the A C is switched off 5 4 Setting of the desired temperature The set ...

Page 9: ... 11 indicates that the unit is in cooling mode at the moment The ECON mode can be activated by pressing and holding key Set Tempera ture Minus 7 While the key is pressed the display changes temporarily This is no fault no settings are changed Press and hold Now the ECON mode is activated and the ECON symbol 12 is displayed In ECON mode the compressor is locked The A C operates only in ventilation ...

Page 10: ...5 8 Demisting operation If the windows are steamed up the demisting mode can be activated Press key Demisting 4 to activate demisting operation mode Press The symbol Demisting 10 on the display indicates that the demisting mode is activated In demisting mode the compressor is operating and the blower speed is raised to 100 If the key Demisting 4 is pressed again the demisting mode gets deactivat e...

Page 11: ...mbol Inside Temperature 2 appears By pressing key MODE 6 once again the display changes over to set tem perature indication Press The set temperature is displayed When the demisting mode is activated the blower speed is increased to 100 The speed can be adjusted manually on demand But to reach maximum demisting performance the blower speed should not be decreased If the set temperature is adjusted...

Page 12: ...nd maintenance works please contact via email TKD konvekta com Danger of accidents Qualified staff in charge of installation and maintenance have to be trained in accordance with EN 378 Part 4 and EC No 307 2008 and must strictly follow the legal provisions Any works or modifications at the air conditioner which are carried out improperly can lead to mal function and so endanger operational reliab...

Page 13: ...as switched off check evaporator blower replace if necessary outside temperature too low possible icing of evaporator switch on ventilation only 2 evaporator coil dirty clean evaporator coil with compressed air compressor does not compress check high and low pressure replace compressor if necessary excess pressure pressure too high check axial fans check fuses at switchboard clean condenser coil w...

Page 14: ...lance Resolution for the waste management of old cars and the adaptation of road prescriptions Resolution EC No 2037 2000 of the Euro pean Parliament and of the Council for ma terials that affect the ozone layer Resolution to prohibit certain ozone destroy ing halogen hydrocarbons The used refrigerant endangers the environment When dealing with refrigerants the existing pre scriptions and regulati...