110013961AA
date of change: 18.08.2008
page: 5/19
2.3
Connecting and Safety instructions
---- Please read before connecting
Please read before connecting
Please read before connecting
Please read before connecting!
!
!
! ----
•
For safety reasons the control unit FR4
FR4
FR4
FR4 shall not be used for applications different from those described
in this manual.
•
Before use please check the limits of this control unit as well as its applications.
Safety instructions
Safety instructions
Safety instructions
Safety instructions
Before connecting the unit please check wether the supply voltage is correct. Please pay attention to the
prescribed ambient conditions respectively their humidity and temperature limits. Should these conditions
not be followed, malfunctions can not be excluded.
Attention
Attention
Attention
Attention::::
Before switching-on the unit, please check once again correct connection.
Never run this unit without housing.
Please install the sensor where it is not accessible for the end customer
Please consider the maximum current which can be applied to each relay (see technical data / point 1).
Please ensure that all sensors are installed with enough distance to under-voltage cables. By this, distorted
temperature measurements can be avoided and the unit is protected from voltage interspersion by the
sensor-inputs.
Installation
Installation
Installation
Installation aaaand
nd
nd
nd mounting
mounting
mounting
mounting
The control unit FR4
FR4
FR4
FR4 shall be mounted on panel in a 71x29 mm
71x29 mm
71x29 mm
71x29 mm hole and fixed by the fastening frame.
For a faultless operation the ambient temperature should be between 0 und 50 °C. Please avoid intense
vibration, aggressive gases, high fouling or humidity.
You have to care for enough air circulation at the air slots.
Ele
Ele
Ele
Elecccctr
tr
tr
trical
ical
ical
ical co
co
co
connections
nnections
nnections
nnections
The control unit FR4
FR4
FR4
FR4 is provided with screw terminals for a wire diameter of
≤
2,5mm
2
. Before voltage
supply is connected please make sure that the auxiliary energy complies with the instrument’s require-
ments. Please ensure that the inlet cables are installed with enough distance to under-voltage cables.
Do not exceed the maximum voltage allowed on each relay.
Sensor
Sensor
Sensor
Sensor connections
connections
connections
connections
The sensor peak should be mounted upwards in order to avoid accumulation of liquids or condense wa-
ter. We recommend to place the thermostat away from air flow in order to have a correct measurement
of the average room temperature.
These instructions contain all necessary information for installation of the control unit. In case you need
further information respectively explanation our technical after-sales service will be at your disposal
(
℡
06691/76 –124, or
).
In the course of further developments we reserve the right to technical modifications without prenotice.
Guarantee and liability conditions of Konvekta AG’s general business conditions are not enlarged by the
above notes. Indications and photos should neither be copied and circulated nor used for competitor’s
purposes. All rights according to the copyright remain expressly reserved.
Manufacturer: KONVEKTA AG,
KONVEKTA AG,
KONVEKTA AG,
KONVEKTA AG, P.O. Box
P.O. Box
P.O. Box
P.O. Box 2280, 34607 Schwalmstadt
2280, 34607 Schwalmstadt
2280, 34607 Schwalmstadt
2280, 34607 Schwalmstadt, Germany
, Germany
, Germany
, Germany