22
No signal
Switch on TX
Connect receiver battery
Connect ESC correctly to Rx
Disconnect Jumper within 10 s after
initialization
Signals – then steady light or no signal
Throttle position „back" is too close to
throttle position „front"
Distance between throttle position „back"
and throttle position „front" is too large.
Program throttle control to +/-100 %,
lower if necessary
Program no shift of throttle control (offset)
at TX.
10.2 Errors during operation
Unexpected motor shut down
If throttle is not used after motor shut down,
the LED shows shut down reason via blink
code.
If disconnection reason cannot be identified,
our service should be contacted to avoid
damage of the ESC.
LED is blinking one time
Under voltage disconnection, battery
empty
LED is blinking two times
Over current disconnection. Maximum
current of ESC has been exceeded.
Change gear ratio or use less cells.
LED is blinking three times
Over temperature Amplifier. Improve
cooling of ESC.
LED is blinking four times
Over temperature BEC. Improve cooling
of ESC.
LED is blinking five times
Transmitter signal. Check transmitter /
receiver
LED is blinking six times
Under- / Over voltage BEC
LED is blinking seven times
very high voltage peak
LED is blinking eight times
too much high current peaks.
LED is blinking nine times
Check motor, cable and connector
11. Technical assistance, Advice, Hotline
Tel.:
+49
(0)7457 9435 0
Fax:
+49
(0)7457 9435 90
Email:
in
Internet:
www.kontronik.com
11.1 Recycling
Electronic components should not be
disposed
with household waste, they have to be
disposed
according to legal and environmental r
egulations.
National and local disposal r
egulation has to be
r
espected!
11.2 Warranty
SOBEK Drives GmbH guarantees this product to
be
free from factory defects in material and
workmanship for a period of 24 months from date of
purchase and purchase within the EU. Warranty for
purchases made outside the EU is in line with the
respective legal r
egulations.
This warranty does not cover: suitability
for specific
application, components worn
by use, application of
reverse or improper v
oltage, tampering, misuse or
shi
pping.
Our warranty liability shall be limited to r
epairing or
replacing the unit to our original s
pecifications.
Because we have no control over the ins
tallation or
use of these products, in no case shall our liability
exceed the original cost of the
product.
All warranty claims terminate with opening
of the
product. To accept guarantee the
original bill on
which the product the date of
purchase and the
dealer is named must be sent
together with the
product.
Also a detailed description of fault is necessary
and should be in
cluded:
· used motor,
· propeller diameter
· number and type of batteries
· time of failure
Please use the service form
for sending in to:
SOBEK Drives GmbH
- Servicecenter -
Etzwiesenstrasse 35/1
D-72108 Rottenburg
Please do not forget to write your address
on
the package in capital letters!
!