System Mounting
In order to adapt the SmartClient-SLUx-170-P for mounting Kontron offers different mounting solution such as:
Panel mount: SmartClient-SLUx-170-P configuration with the corresponding supplied mounting clamps for
vertical installation into an instrument / wall / other cabinet
VESA mount: SmartClient-SLUx-170-P configuration with a VESA mounting kit for vertical installation onto a wall
/ VESA stand / VESA pole
5.1.1.
System Mounting by Use of the Mounting Clamps
Depending on the ordered SmartClient-SLUx-170-P configuration, your system is supplied with a number of the
corresponding mounting clamps (Figure 3) sufficient to mount the system into an instrument / wall / other cabinet.
Figure 3: Mounting clamp
Table 1: Specification for mounting by use of the mounting clamps
Model
SmartClient-SLUx-170-P
Cut-out for mounting to a wall /
panel (W x H) [mm]
378.3 x 318.9 mm
(14.89" x 12.56")
Thickness for the mounting wall /
panel for proper mounting [mm]
1.5 ~ 6
Number of the clamps with screws
for mounting to a wall / panel
11
(3 for top / right / left side, 2 for bottom side)
Required tool
Phillips screwdriver
In order to ensure IP65 front sealing against dust and water,
mount the system on a non-
textured surface
.
Before you install the SmartClient-SLUx-170-P into a panel or a wall, verify the perfect
condition of the gasket at the rear of the front bezel.
The gasket has to be in place without surface imperfections / defects and dirt.
Ensure the vertical and horizontal alignment of the system.
The screen of the SmartClient-SLUx-170-P is fragile. Handle with care to prevent personal
injury or material damage. Always use two hands when carrying the device.
The screen of the SmartClient-SLUx-170-P is provided with a protective film. Only remove
this protective material after the installation of the SmartClient-SLUx-170-P.
To mount the system to a wall or to a panel, please proceed according to the steps described: