NSC2U Server—5
Kontron IP Network Server NSC2U
Product Guide, rev. 1.4
December 2009
120
6. Install the CPU fan assembly. For instructions, see
.
7. Install the drive bay assembly. For instructions, see
Drive Bay Assembly” on page 114
.
8. Connect all cables and the bridge board to the server board. Use
“NSC2U Server System Cable Routing” on page 51
as a reference.
9. Install the processor air duct. For instructions, see
Section 3.2.6, “Installing the
Processor Air Duct” on page 28
.
10. If this is the last task you are performing, replace the top cover of the chassis.
Reconnect all the external devices and plug in the power cord(s).
For information about mounting the server in a rack, see
the Server into a Rack” on page 48
.
5.7
Replacing the Backup Battery on the Server Board
The lithium battery on the server board powers the real-time clock (RTC) for up to 10
years in the absence of power. When the battery starts to weaken, it loses voltage, and
the server settings (for example, the date and time) stored in CMOS RAM in the RTC
may be wrong. Contact your Kontron sales representative for a list of approved
devices.
Caution:
Before replacing the battery, you must first take the server out of service, turn off all
peripheral devices connected to the system, turn off the system by pressing the power
button, and unplug the power cord from the system or wall outlet.
WARNING
Danger of explosion if battery is replaced incorrectly. Replace only with the same or
equivalent type recommended by the equipment manufacturer. Discard used batteries
according to manufacturer’s instructions.
WARNING
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med
batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
ADVARSEL
Lithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av
apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
VARNING
Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent
typ som rekommenderas av apparattillverkaren. Kassera använt batteri enligt
fabrikantens instruktion.
VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan
laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden
mukaisesti.
1. Power down the server system and unplug all peripheral devices and the power
cable.
2. Remove the chassis cover. For instructons, see
3. Remove the processor air duct. For instructions, see
Processor Air Duct” on page 27
.
4. Locate the battery. (See
.)