12. Technical Data
KISS 1U_SBC_762 – User's Guide (Version 1.1)
www.kontron.com
37
12.1.
Electrical Specifications
The corresponding electrical specifications of your KISS 1U platform can be found on the type label.
12.2.
Mechanical Specifications
Dimensions
KISS 1U (Standard Version)
Height
1U (44 mm) (1,73")
Width
Front: 19”; Chassis: 430 mm (16.9")
Depth
Front 14 mm (0.55“); Chassis: 469 mm (18.465")
Weight
(without packaging)
Approx. 7.50 kg (16.535 lbs.)
Chassis
Chassis, black (RAL 7021)
Front access panel: blue (RAL 5017)
12.3.
Environmental Specifications
Thermal Management
4x system fan
PSU fan
CPU fan
Operating Temperature /
Relative Humidity
0 … +50 °C @5-95 % not condensing [at +55 °C (131 °F) at 10% POH per month]
(32 .. 122 °F @5-95 % not condensing [+55 °C (131 °F) at 10% POH per month]
Storage / Transport
Temperature / Relative
Humidity
-20 … +70 °C @ 5-95 % not condensing
(-4 … 158 °F @ 5-95 %) not condensing
Max. Operation Altitude
2,000 m (6,560 ft)
Max. Storage / Transport
Altitude
10,000 m (32,810 ft)
Operating Shock
5 G, 11 ms, half sine
Storage / Transit Shock
30 G., 11 ms, half sine
Operating Vibration
10 – 500 Hz, 1.0 G
Storage / Transit Vibration
10 – 500 Hz, 2.0 G
Acoustic Noise
< 35 dB(A) (at 1 m in front of the system, full load)