background image

 

7. Product Description 

 

KISS 1U_SBC_762 – User's Guide (Version 1.1) 

 

www.kontron.com 

15 

 

 

Fig. 6: KISS 1U platform - front side 

 

 

The KISS 1U platforms are designed to be operated in horizontal position only. 

When powering on the KISS 1U platform, make sure that the air intake and exhaust openings are not 
obstructed by objects. 

 

Summary of Contents for KISS 1U PCI762-A

Page 1: ...www kontron com User s Guide KISS 1U KISS 1U PCI762 A User s Guide Version 1 1 1056 7706...

Page 2: ...Canada 12 6 Scope of Delivery 13 6 1 Type Label and Product Identification 13 7 Product Description 14 7 1 Front Side 16 7 1 1 Controls and Indicators 17 7 1 2 Ports on the Front Side 18 7 1 3 Filter...

Page 3: ...version with opened access panel 14 Fig 6 KISS 1U platform front side 15 Fig 7 Front rackmount version with the front access panel closed 16 Fig 8 Front side desktop version with opened front access...

Page 4: ...ding the cover back will pull out the cover fixing brackets from the retaining brackets of the chassis 27 Fig 27 Removing the cover 27 Fig 28 Front side detail Position of the filter mats 32 Fig 29 Fr...

Page 5: ...ill be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description of processes and instructions...

Page 6: ...Applications is entirely at your risk To minimize the risks associated with your products and applications you should provide adequate design and operating safeguards You are solely responsible for c...

Page 7: ...visit our website CONTACT US Customer Support Find Kontron contacts by visiting http www kontron com support Customer Service As a trusted technology innovator and global solutions provider Kontron e...

Page 8: ...ge to the product if the corresponding warning notices are not observed This symbol indicates that the product or parts thereof may be damaged if the corresponding warning notices are not observed Thi...

Page 9: ...mple 3 2 Exclusion of Accident Liability Obligation Kontron Europe shall be exempted from the statutory accident liability obligation if the user fails to observe the included document General Safety...

Page 10: ...e product To guarantee that sufficient air circulation is available to cool the product please ensure that the ventilation openings are not covered or blocked If a filter mat is provided this should b...

Page 11: ...1 or VDE0100 or EN60204 or UL508 regulations The devices do not generally fulfill the requirements for centralized DC power systems UL 60950 1 Annex NAB D2 and therefore may not be connected to such...

Page 12: ...air ionizes to give added protection 3 Always handle electrostatic sensitive components by their edge or by their casing 4 Avoid contact with pins leads or circuitry 5 Turn off power and input signals...

Page 13: ...USA This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection agai...

Page 14: ...Identification The type label product designation serial number and the inspection status label of your KISS 1U platform are located on the right side of the device System Type Product Name Product Id...

Page 15: ...with up to three drive bays depending on the system configuration D1 one 5 25 Slim front accessible drive bay D2 one 3 5 front accessible drive bay or an front accessible slim drive D3 one 3 5 interna...

Page 16: ...on 1 1 www kontron com 15 Fig 6 KISS 1U platform front side The KISS 1U platforms are designed to be operated in horizontal position only When powering on the KISS 1U platform make sure that the air i...

Page 17: ...re connected to the USB ports on the front of the device the front access panel can not be closed and locked Fig 7 Front rackmount version with the front access panel closed 1 19 bracket with handle 2...

Page 18: ...ower LED green This LED Fig 10 pos 2 lights up green when the system is switched on using the power button Please observe the Warning below Prerequisite The system must be connected to an appropriate...

Page 19: ...e chassis front panel Fig 29 pos 5 The filter mat holders are fastened to the chassis front panel Fig 8 pos 10 and Fig 28 pos 1 by knurled screws Fig 28 pos 3 The filter mats are inserted into the fil...

Page 20: ...Rear side of the cover with captive knurled screws 2 Free card slots for 1x PCIe x16 1x PCIe x4 or 1x PCI 32 Bit 1x PCIe x4 3 COM1 RS232 4 COM2 RS232 5 External interfaces of the SBC PCI 762 card 6 Ai...

Page 21: ...7 2 2 Power Supply and ON OFF Switch of the PSU The power supply is located on the rear side of the KISS 1U platform The KISS 1U platform is equipped with an AC wide range power supply unit The corres...

Page 22: ...available at the left and right side of the unit These can be used in order to attach slide rails not included in the scope of delivery to the KISS 1U for system installation into a 19 industrial cabi...

Page 23: ...by selecting the product Please observe that the KISS 1U platform is designed to be operated in horizontal position only Fig 20 Example of KISS 1U Configuration with SBC PCI 762 Single Board Computer...

Page 24: ...lane Available Slots for Exoansion Cards KISS 1U SBC backplane Riser card 1 1x PCI 32 Bit 33 MHz 1x PCIe x16 Riser card 2 1x PCIe x4 1x PCIe x16 Fig 21 Grounding stud Fig 22 Grounding stud Depending o...

Page 25: ...tem Fig 23 Exchangeable fan slide in modules with captive knurled screws 1 Captive knurled screws for fixing the fan slide in modules in the corresponding fan compartment 2 Cables and connectors for t...

Page 26: ...the cover three at the front edge Fig 24 pos 4 and one at the rear edge Fig 24 pos 3 of the cover When closing the cover make sure that the fixing brackets Fig 24 pos 2 and pos 4 will be inserted pro...

Page 27: ...ch the rubber feet included refer to chapter 6 Scope of Delivery proceed as follows Before attaching the rubber feet ensure that your system is switched off and disconnected from the main power source...

Page 28: ...instruction can result in damage to the device Please read information provided by the manufacturer of any expansion cards before installing them or removing them from your system To install or remov...

Page 29: ...erve the instructions described in this user s guide Please consider the instructions described in the included chapter 4 General Safety Instruction for IT Equipment Please consider the hints included...

Page 30: ...15 pos 8 of the PSU there is still a standby voltage of 5 VSb on the SBC The unit is completely disconnected from the mains only when the power cord is disconnected either from the mains or the unit T...

Page 31: ...ED SYSTEMS or WINDOWS 7 PROFESSIONAL FOR EMBEDDED SYSTEMS operating systems The terms and condition for using the pre installed operating systems are defined in the document MICROSOFT SOFTWARE LICENSE...

Page 32: ...laced during operation This should only be carried out by a qualified specialist who is aware of the associated dangers Keep your hands and fingers away from rotating parts of the fan Before taking ou...

Page 33: ...29 and Fig 31 1 Chassis front side 2 Filter mat 3 Filter pad holder with knurled screw 4 Tapped hole for knurled screw 5 Vent openings of the chassis front panel 6 Positioning holes for filter mat hol...

Page 34: ...g and drying the filter mat place it in the filter mat holder Re attach the filter mat holder to the front of the chassis 7 Screw on the filter mat holder to the chassis using the fixing screw Faulty...

Page 35: ...the lithium battery from the holder by pulling the ejector spring outwards 4 Place a new lithium battery in the battery holder 5 Pay attention to the polarity of the battery 6 The lithium battery mus...

Page 36: ...ron stocks slide rails for installing the KISS 1U in an industrial cabinet These rails can be ordered separately Fig 32 Attaching the inner section of the slide rails Fig 33 KISS 1U platform with slid...

Page 37: ...onally equipped depending on the system configuration ordered refer to KISS 1U System Configuration Guides Free Expansion Slots optionally equipped depending on the system configuration ordered refer...

Page 38: ...el blue RAL 5017 12 3 Environmental Specifications Thermal Management 4x system fan PSU fan CPU fan Operating Temperature Relative Humidity 0 50 C 5 95 not condensing at 55 C 131 F at 10 POH per month...

Page 39: ...EU Elektrical Safety Harmonized Standards EUROPE Information technology equipment Safety Part 1 General requirements EN 60950 1 2006 A11 2009 A1 2010 A12 2011 U S A CANADA to meet UL60950 1 2007 CSA C...

Page 40: ...9 pin D SUB Connector male 1 DCD Data Carrier Detect 2 RXD Receive Data 3 TXD Transmit Data 4 DTR Data Terminal Ready 5 GND Signal Ground 6 DSR Data Set Ready 7 RTS Request to Send 8 CTS Clear to Sen...

Page 41: ...ort 2 0 Pin Signal Name 4 pin USB Connector Type A Version 2 0 1 VCC 2 Data 3 Data 4 GND 13 1 4 USB3 0 Port Pin Signal Name 9 pin USB Connector Type A Version 3 0 2 0 USB 2 0 contact pins USB 3 0 cont...

Page 42: ...es The result is an accelerated time to market reduced total cost of ownership product longevity and the best possible overall application with leading edge highest reliability embedded technology Kon...

Reviews: