![Kontron FlexATX-KBL-S-C236 User Manual Download Page 59](http://html.mh-extra.com/html/kontron/flexatx-kbl-s-c236/flexatx-kbl-s-c236_user-manual_1996460059.webp)
FlexATX-KBL-S-C236 – Rev. 1.1
www.kontron.com
// 59
Sub-Screen
Function
Description
Dram
Power
Meter
Use user
provide
d
weights,
scale
factors,
and
channel
power
floor
values
Enabled: User provided
power weights, scale factor,
and channel power floor
values are used.
Disabled: BIOS set power
weights, scale factor, and
channel power floor
Dram
Power
Meter
Setting
Display Dram Power Meter
Setting
Memory
Thermal
Reportin
g
Lock
Thermal
Manage
ment
Register
s
Enabled: lock several PCU
registers related to DDR
power/thermal
management
Extern
Therm
Status
Enabled: The value from
EXTTS is used
Disabled: Pcode ignores the
EXTTS
Closed
Loop
Therm
Manage
Enabled: CLTM pcode
algorithm will be used
Open
Loop
Therm
Manage
Enabled: OLTM pcode
algorithm will be used
Warm
Thresho
ld Ch0
Dimm0
Range [255;0]=[31.875;0] in
W for OLTM, [127.5;0] in C
for CLTM
Warm
Thresho
ld Ch0
Dimm1
Range [255;0]=[31.875;0] in
W for OLTM, [127.5;0] in C
for CLTM
Hot
Thresho
ld Ch0
Dimm0
Range [255;0]=[31.875;0] in
W for OLTM, [127.5;0] in C
for CLTM
Hot
Thresho
ld Ch0
Range [255;0]=[31.875;0] in
W for OLTM, [127.5;0] in C
for CLTM