3.5
MTBF
The following MTBF (Mean Time Between Failure) values were calculated using a combination of
manufacturer’s test data, if the data was available, and a Bellcore calculation for the remaining parts.
The Bellcore calculation used is “Method 1 Case 1”. In that particular method the components are
assumed to be operating at a 50 % stress level in a 40° C ambient environment and the system is
assumed to have not been burned in. Manufacturer’s data has been used wherever possible. The
manufacturer’s data, when used, is specified at 50° C, so in that sense the following results are slightly
conservative. The MTBF values shown below are for a 40° C in an office or telecommunications
environment. Higher temperatures and other environmental stresses (extreme altitude, vibration, salt
water exposure, etc.) lower MTBF values.
®
System MTBF (hours) :
174189
Notes: Fans usually shipped with Kontron Embedded Modules GmbH products have 50,000-hour typical operating
life. The above estimates assume no fan, but a passive heat sinking arrangement Estimated RTC battery life
(as opposed to battery failures) is not accounted for in the above figures and need to be considered for
separately.Battery life depends on both temperature and operating conditions. When the Kontron unit has
external power; the only battery drain is from leakage paths.
Summary of Contents for ETX -CN8
Page 1: ... Kontron User s Guide ETX CN8 Document Revision 1 3 ...
Page 2: ...This page intentionally left blank ...
Page 12: ...3 Specifications Kontron User s Guide ETX CN8 12 3 1 1 Block diagram ...
Page 51: ...9 BIOS Operation Kontron User s Guide ETX CN8 51 9 3 2 Advanced Menu ...
Page 72: ...9 BIOS Operation Kontron User s Guide ETX CN8 72 9 3 6 Exit Menu ...