1.3.5
Humidity
The board is designed to meet Bellcore GR63, Section 4.1
•
Operating: 93% (non-condensing) at 40°C
•
Non-Operating: 5%-95% (non-condensing) at 40°C
1.3.6
Altitude
The board is designed to meet the following requirements:
•
Operating: 15000 ft, additional cooling might be required above 6000ft
•
Non-Operating: 60000 ft
1.3.7
Vibration
The board is designed to meet the following requirements:
•
Standard
•
DIN/IEC 60068-2-6 (Sine)
•
ANSI/Vita 47-2005, Environmental class EAC1
•
Bellcore GR-63, Section 4.4
•
10Hz to 300Hz, Acceleration: 2 g, Test Cycle: 1 oct./min., Cycle Count: 10/axis, 3 axis
•
5 Hz to 100 Hz Power Spectral Density (PSD) = 0.04 g2/Hz
1.3.8
Bump
The board is designed to meet the following requirements:
•
Standard
•
DIN/IEC 60068-2-29
•
Peak Acceleration: 15 g, Shock Duration: 11 ms half sine, Shock Counts: 500/direction, Recovery Time: 1 s
1.3.9
Shock
The board is designed to meet the following requirements:
•
Standard
•
DIN/IEC 60068-2-27
•
Peak Acceleration: 30 g, Shock Duration: 9 ms half sine, Recovery Time: 5 s, Shock Count: 3/direction, 6 directions