![Kontron CP3005-SA User Manual Download Page 46](http://html1.mh-extra.com/html/kontron/cp3005-sa/cp3005-sa_user-manual_1996264046.webp)
CP3005-SA – Rev. 0.6 Preliminary
// 46
Workload Maximum: These values represent the maximum power dissipation achieved through the use of
specific tools to heat up the processor cores and graphics controller. These values are unlikely to be reached in
real applications.
Table 31: CP3005-SA Power Consumption
Workload
Intel® Core™ i7-
5700EQ 2.6 GHz
Intel® Core™ i5-4410E
2.9 GHz
Intel® Core™i3-4112E
1.8 GHz
uEFI Shell
22.0 W
19.2 W
13.8 W
Idle
11.8 W
12.7 W
11.7 W
Typical
44.9 W
47.3 W
21.2 W
5.3.
Power Consumption of CP3005-SA Accessories
The following table indicates the power consumption of the CP3005-SA accessories.
Table 32: Power Consumption of CP3005-SA Accessories
Module
Power Consumption
DDR3L SDRAM from one to two 18-chip memory modules
(JEDEC raw card D)
approx. 5.8 W
SATA Flash module
less than 0.5 W
Gigabit Ethernet (per interface)
less than 0.5 W
5.4.
Maximum Power Consumption of XMC Modules
A maximum power of 15 W is available on the XMC slot (located on the MMEXT-XMC02 module) and it can be
arbitrarily divided on the 3.3 V and 5 V (VPWR) voltage lines. XMC modules are based on 3.3 V power along with
variable power (VPWR) defined as either 5 V or 12 V in the ANSI/VITA 42.0-200x XMC Switched Mezzanine Card
Auxiliary Standard specification. On the CP3005-SA, the VPWR is configured to 5 V.
The following table indicates the current of a XMC module.
Table 33: XMC Module Current
Voltage
Continuous Current
Peak Current
3.3 V
0.75 A
1.0 A
5 V (VPWR)
2.5 A
3.0 A
+12 V
0.6 A
0.8 A
XMC integrators should carefully review the power ratings, cooling capacity and airflow
requirements in the application prior to installation of an XMC module on the 8HP CP3005-
SA with MMEXT-XMC02 extension module.
5.5.
Current Limits
The CP3005-SA has a hot swap controller for the +3.3V and +5V input voltage. The trip current limits in case of
catastrophic failure are:
+3.3 V: 16.5 A minimum, 21.9 A maximum
+5 V: 33.0 A minimum, 43.8 A maximum
The maximum thermal operating current is 11.0 A for the +3.3 V supply and 17.6 A for the +5 V supply. The customer
configuration/application shall not exceed these limits for a maximum operating ambient temperature of 60°C.