COMe-cBT6 / Introduction
20
3.7. Environmental Specification
3.7.1. Temperature Specification
Kontron defines following temperature grades for Computer-on-Modules in general. Please see chapter 'Product
Specification' for available temperature grades for the COMe-cBT6
Temperature Specification
Operating
Non-operating
Validated Input Voltage
Commercial grade
0°C to +60°C
-30°C to +85°C
VCC: 4.75 - 20V
Extended Temperature (E1)
-25°C to +75°C
-30°C to +85°C
VCC: 12V
Industrial grade by
Screening
(XT)
-40°C to +85°C
-40°C to +85°C
VCC: 12V
Industrial grade by
Design
(E2)
-40°C to +85°C
-40°C to +85°C
VCC: 4.75 - 20V
Operating with Kontron heatspreader plate assembly
The operating temperature defines two requirements:
» the maximum ambient temperature with ambient being the air surrounding the module.
» the maximum measurable temperature on any spot on the heatspreader's surface
Test specification:
Temperature Grade
Validation requirements
Commercial grade
at 60°C HSP temperature the CPU @ 100% load needs to run at nominal frequency
Extended Temperature (E1)
at 75°C HSP temperature the CPU @ 75% load is allowed to start speedstepping for thermal protection
Industrial grade by
Screening
(XT)
at 85°C HSP temperature the CPU @ 50% load is allowed to start throttling for thermal protection
Industrial grade by
Design
(E2)
at 85°C HSP temperature the CPU @ 50% load is allowed to start throttling for thermal protection
Operating without Kontron heatspreader plate assembly
The operating temperature is the maximum measurable temperature on any spot on the module's surface.
3.7.2. Humidity
» 93% relative Humidity at 40°C, non-condensing (according to IEC 60068-2-78)
Summary of Contents for COMe-cBT6
Page 1: ...www kontron com COMe cBT6 User Guide COMe cBT6 User Guide Doc Rev 2 0...
Page 2: ...www kontron com COMe cBT6 User Guide This page has been intentionally left blank...
Page 27: ...COMe cBT6 Introduction 25 3 11 Module Dimensions All...
Page 62: ...COMe cBT6 User Guide 60 System Information...
Page 65: ...COMe cBT6 User Guide 63 Platform Information...
Page 78: ...COMe cBT6 User Guide 76 South Cluster Configuration...
Page 86: ...COMe cBT6 User Guide 84 View SMBIOS event log...
Page 90: ...COMe cBT6 User Guide 88 7 5 4 Boot...