75
AT8050
www.kontron.com
4.3.4
Clock E-Keying Information
The clock ekeying is used to find and activate matching clock pairs to/from available clock sources and clock
receivers.
The board has a clock generator used as the (PCIe) FCLKA of AMC B1. Additionally, clocks from/to the ATCA
backplane can be driven to/from the AMC B1 site using an on-carrier clock multiplexer.
The following table gives the clock resources id assignment mapping.
Table 4-33:Clock resources id assignment mapping
4.3.4.1
Clock Point-To-Point Connectivity Information
The following table gives all the clock link paths available on the Front Board Unit, as they appear in the FRU
data in the Carrier Clock Point-to-Point Connectivity Record Table record.
Table 4-34:Carrier Clock Point-to-Point Connectivity Record Table
OnBoard Clock Device
Clock Resource Id
PCIe Clock Generator
0
Clock Multiplexer
1
Field
Value
Description
Record Type ID
C0h
Record format version
02h
Record Length
*Calculated
Record Checksum
*Calculated
Header Checksum
*Calculated
Manufacturer ID
00315Ah
PICMG Record ID
PICMG Record ID
2Ch
Carrier Clock Point-To-Point Connectivity Record
Record Format Version
00h
Clock Point-To-Point Resource Descriptor Count (m)
0x02
Clock Point-To-Point Resource Descriptor
Clock Resource Id
0x00
7:6 00b = On-Carrier device
5:4 0h (reserved)
3:0 On-Carrier Device 0 ( PCIe clock generator )
Clock Point-to-Point Connection Count
0x01
Point-to-Point Clock Connection descriptor
Local Clock Id
0x00
On-Carrier Clock Id 0
Remote Clock Id
0x05
AMC.0 R2.0 FCLKA clock
Remote Clock Resource Id
0x45
7:6 01b = AMC
5:4 0h (reserved)
3:0 AMC Site Number ( 5 = AMC B1)
Clock Point-To-Point Resource Descriptor