Kontron AdvancedTCA AT8050 User Manual Download Page 107

Software Setup

91

AT8050

www.kontron.com

5.1.4.3.1

SATA Port 0 (PM) Configuration sub-menu 

5.1.4.3.2

SATA Port 1 (SM) Configuration sub-menu 

5.1.4.3.3

SATA Port 2 (PS) configuration sub-menu fields.

Feature 

Option 

Description 

Help text 

Device 

N/A 

Display the device type (Hard disk). 

Display only 

Vendor 

N/A 

Display the vendor string of the disk. 

Display only 

Size 

N/A 

Display the size of the disk. 

Display only 

Ultra DMA 

N/A 

Display the current speed of the drive. 

Display only 

S.M.A.R.T. 

N/A 

Display the status of the Self-Monitoring, 

Analysis, and Reporting Technology. 

Display only 

Type 

Auto 

Not Installed 

Auto will detect the device.  Not installed will 

not detect the device. 

Select the type of device 

connected to the 

system. 

Feature 

Option 

Description 

Help text 

Device 

N/A 

Display the device type (Hard disk). 

Display only 

Vendor 

N/A 

Display the vendor string of the disk. 

Display only 

Size 

N/A 

Display the size of the disk. 

Display only 

Ultra DMA 

N/A 

Display the current speed of the drive. 

Display only 

S.M.A.R.T. 

N/A 

Display the status of the Self-Monitoring, 

Analysis, and Reporting Technology. 

Display only 

Type 

Auto 

Not Installed 

Auto will detect the device.  Not installed will 

not detect the device. 

Select the type of device 

connected to the 

system.

Feature 

Option 

Description 

Help text 

Device 

N/A 

Display the device type (Hard disk). 

Display only 

Vendor 

N/A 

Display the vendor string of the disk. 

Display only 

Size 

N/A 

Display the size of the disk. 

Display only 

Ultra DMA 

N/A 

Display the current speed of the drive. 

Display only 

S.M.A.R.T. 

N/A 

Display the status of the Self-Monitoring, 

Analysis, and Reporting Technology. 

Display only 

Type 

Auto 

Not Installed 

Auto will detect the device.  Not installed will 

not detect the device. 

Select the type of device 

connected to the 

system. 

Summary of Contents for AdvancedTCA AT8050

Page 1: ...If it s embedded it s Kontron Kontron User s Guide AT8050 Document Revision 1 5 January 2014...

Page 2: ...stomers may reprint and use this user s guide in other publications Customers may alter this user s guide and publish it only after they remove the Kontron name cover and logo Kontron reserves the rig...

Page 3: ...Storing Boards xiii Regulatory Compliance Statements xiv Limited Warranty xv 1 Product Description 2 1 1 Product Overview 2 1 2 What s Included 2 1 3 Board Specifications 3 1 4 Compliance 5 1 5 Hot Pl...

Page 4: ...26 2 13 Telecom Clock Option 26 2 14 Redundant IPMC Firmware BootBlock 26 2 15 LEDs Description 27 2 15 1 Hot Swap LED LED0 27 2 15 2 Out Of Service LED1 27 2 15 3 Healthy LED LED2 27 3 Installing the...

Page 5: ...Setup Utility 84 5 1 2 Menu Bar 86 5 1 3 Main Menu 87 5 1 4 Advanced Menu 88 5 1 5 Security Menu 98 5 1 6 Boot Menu 99 5 1 7 System Management Menu 104 5 1 8 Exit Menu 113 5 2 Boot Utilities 113 5 2 1...

Page 6: ...J10 B 3 B 6 Serial Port COM1 J12 B 3 B 7 Synchronisation Clocks Update Channel J20 B 4 B 8 USB Flash Drive J22 B 4 B 9 Base Interface Fabric Intercface J23 B 5 B 10 RTM Connector J30 B 6 B 11 Power P...

Page 7: ...Figure 2 6 AMC to Fabric Interface and Management to Front Panel 20 Figure 2 7 AMC to Fabric Interface and Management to AMC 21 Figure 2 8 AMC to Fabric Interface and Management to RTM 22 Figure 2 9 M...

Page 8: ...4 Table 4 9 SDR Device Supported Commands for IPMC 44 Table 4 10 SEL Device Supported Commands for IPMC 44 Table 4 11 LAN Device Supported Commands for IPMC 45 Table 4 12 Serial Modem Device Supported...

Page 9: ...onnectivity details for Onboard Fabric Channel 2 Switch 73 Table 4 32 AMC connectivity details for FPGA Based UART 74 Table 4 33 Clock resources id assignment mapping 75 Table 4 34 Carrier Clock Point...

Page 10: ...thorized electronics service personnel should access the interior of the computer The power supplies produce high voltages and energy hazards which can cause bodily harm Use extreme caution when insta...

Page 11: ...are at an ESD workstation or grounded This will discharge any static electricity that may have built up in your body When transporting a sensitive component first place it in an antistatic container...

Page 12: ...assumes no responsibility as far as patents or other rights of third parties are concerned The following is a summary of chapter contents Chapter 1 Product Description Chapter 2 Board Features Chapter...

Page 13: ...ions that might require the use of a Caution or a Warning Note Indicate information that is important for you to know Signal Path Indicate the places where you can fin the signal on the board Jumper S...

Page 14: ...nectors are properly connected Verify your boot devices If the system does not start properly try booting without any other I O peripherals attached including AMC adapters Make sure your system provid...

Page 15: ...ontron equipment meets or exceeds safety requirements based on the IEC EN UL CSA 60950 1 family of standards entitled Safety of information technology equipment All components are chosen to reduce fir...

Page 16: ...cost of purchase if appropriate In the event of repair refunding or replacement of any part the ownership of the removed or replaced parts reverts to Kontron and the remaining part of the original gu...

Page 17: ...8050 Chapter 1 Product Description www kontron com 1 1 Product Overview 2 1 2 What s Included 2 1 3 Board Specifications 3 1 4 Compliance 5 1 5 Hot Plug Capability 5 1 6 Interfacing with the Environme...

Page 18: ...NI which enables fast and secure data encryption and decryption in AES based communications cryptographic workloads and offers a significant increase in performance compared to the current pure softw...

Page 19: ...O Front Panel Serial RJ 45 2 i82576 Management LAN RJ 45 2 USB PCIe Gen2 5Gb s in Update Channel AMC Carrier ATCA blade Intel i82599 10Gb s or 1Gb s Ethernet Controller to Fabric Interface Intel i825...

Page 20: ...itor power voltages memory and all critical components temperature is monitored Extensive sensors monitoring around 100 IPMI sensors and event generation base on thresholds and discrete reading OS Com...

Page 21: ...r installed in the system while it is on without powering down the system Please refer to the PICMG3 0R3 0 specification for additional details about Hot Swap The AT8050 supports PCI Express Hotplug o...

Page 22: ...the management power to the RTM Once the IPMB L link is working the IPMC accesses the MMC to retrieve FRU data After knowing the type of RTM inserted the IPMC negotiates with the shelf manager in orde...

Page 23: ...2 1 AMC Expansion The AMC slot provides an AMC 1 type 4 AMC 2 Type E2 and 4 AMC 3 Dual Port SAS This means that the following signaling are supported PCI Express X4 on AMC ports 4 7 PCI Express clock...

Page 24: ...ash Module 12 2 5 Serial ATA Serial Attached SCSI 12 2 6 Update Channel 13 2 7 Real Time Clock NVRAM 13 2 8 Redundant BIOS Flash 13 2 9 Ethernet Interfaces 14 2 10 Serial Interfaces 24 2 11 AMC Mezzan...

Page 25: ...0 1 2 2 1 2 2 3 2 2 4 2 5 3 2 6 62 7 5 3 2 4 5 284 2 4 9 6 6 6 7 6 9 67 67 7 67 6 6 2 6 7 7 67 6 7 7 67 7 67 7 6 3 9 6 5 7 2 7 6 5 AA B C 5 2 3 B C 5 2 3 B C 5 5 5 D4 E B 6 6 B 1 2 2 2 2 284 B B C 1 4...

Page 26: ...on Intel 64 Architecture Enhanced Intel SpeedStep Technology Intel Virtualization Technology Simultaneous Multi Threading 2 2 2 Intel IOH 36D QuickPath interconnect to the CPU 36 PCI Express 2 0 lanes...

Page 27: ...e Capability to daisy chain as many as 127 devices per interface Fast bi directional Isochronous asynchronous interface 480 Mbs transfer rate Standardization of peripheral interfaces into a single for...

Page 28: ...the AMC Bay more details in the AMC Mezzanine section below The RTM8050 features a SAS controller the LSISAS1064e is PCI e rev 1 1 which interfaces with the AT8050 by a dedicated PCI Express connectio...

Page 29: ...er blade such as the AT8402 Kontron AMC carrier via x4 PCI Express link This feature offer additional application possibilities to the AT8050 Consult the AMC carrier blade s technical reference manual...

Page 30: ...panel the i82576EB 1GbE controller can be connected to the Fabric interface instead of the i82599EB 10GbE 10GbE connectivity will no longer be available 2 9 1 3 i82599EB Fabric Interface Features high...

Page 31: ...terface is featured by the second i82576EB dual port 1Gb Ethernet controller By means of cross point switch it can achieve the following connectivity front panel with two 10 100 1000Base T RJ45 interf...

Page 32: ...ernet Interfaces Configurations Note The AMC must be able to support GbE on ports 8 11 Connection from AMC to the Fabric Interface is either PICMG3 1 option 2 2x1GbE or PICMG3 1 option 1 1xGbE Fabric...

Page 33: ...anagement LAN Setting Front Panel 2 System Management OEM E Keying Configuration AMC P8 11 Setting Disabled MGNT 82576EB Front 2x RJ 45 AMC BI 82576EB Ports 9 11 Ports 0 1 RTM Ports 0 1 Ports 0 1 Fabr...

Page 34: ...nt LAN Setting AMC 2 Module 2 System Management OEM E Keying Configuration AMC P8 11 Setting Disabled MGNT 82576EB Front 2x RJ 45 AMC BI 82576EB RTM Ports 0 1 Ports 0 1 Fabric Interface Channel 1 Port...

Page 35: ...ement LAN Setting RTM 2 System Management OEM E Keying Configuration AMC P8 11 Setting Disabled MGNT 82576EB Front 2x RJ 45 AMC BI 82576EB RTM Ports 0 1 Ports 0 1 Fabric Interface Channel 1 Ports 0 3...

Page 36: ...Settings 1 System Management OEM E Keying Configuration Management LAN Setting Front Panel 2 System Management OEM E Keying Configuration AMC P8 11 Setting Fabric Interface In this configuration it is...

Page 37: ...ngs 1 System Management OEM E Keying Configuration Management LAN Setting AMC 2 Module 2 System Management OEM E Keying Configuration AMC P8 11 Setting Fabric Interface In this configuration it is not...

Page 38: ...ettings 1 System Management OEM E Keying Configuration Management LAN Setting RTM 2 System Management OEM E Keying Configuration AMC P8 11 Setting Fabric Interface In this configuration it is not poss...

Page 39: ...Management LAN Setting Fabric Interface System Management OEM E Keying Configuration AMC P8 11 Setting Disabled MGNT 82576EB Front 2x RJ 45 AMC BI 82576EB RTM Ports 0 1 Ports 0 1 Fabric Interface Chan...

Page 40: ...se specification The AMC is hot swappable according to PICMG 3 0 Rev 2 0 and supports mid size AMC units One AMC site is available Characteristics of the AMC are as follow Type B Support mid size sing...

Page 41: ...nsure proper un mount sequence within the operating system AMC port 3 is supplied by the RTM for SAS connectivity The telco clock signals allow the AT8050 to provide clocks to the AMC on TCLKA and TCL...

Page 42: ...es 19 44MHz clocks from the backplane CLK2A and CLK2B and use it as a reference to the DPLL Anyone of the PLL clock outputs can be used to feed the AMC s TCLKA using the FPGA interface If a backplane...

Page 43: ...healthy LED indicates if the blade is powered up and all voltages and temperatures are within specifications During normal operation this LED is ON green This LED is also ON amber when one of the RTM8...

Page 44: ...ty status 0 1 L R B I F I AdvancedTCAR Link Act Off No link Green Link Blinking Activity Speed Off No link Amber 10 100Mb Green 1000 Mb Hard Disk Act Local Remote Off No activity Blinking Activity Bas...

Page 45: ...Chapter 3 Installing the Board www kontron com 3 1 Setting Jumpers 30 3 2 Processor 31 3 3 Memory 31 3 4 Onboard Connectors and Headers 34 3 5 Board Hot Swap and Installation 35...

Page 46: ...0 Reserved Reserved JP2 11 12 Reserved Reserved JP2 13 14 Note More details about the jumper settings can be found on the Quick Reference Sheet J8 J9 JP1 JP2 1 3 5 7 9 11 13 2 4 6 8 10 12 14 1 3 5 7 9...

Page 47: ...DDR3 SDRAM size is 8GBytes per DIMM for a populated 48GBytes maximum Memory modules shall have a validated thermal solution heatsink and may necessitate a certain class of chassis It is recommended t...

Page 48: ...256M 72 REG ECC 0 70 Smart modular VL33B5168F F8M DIMM_DDR3 1066_4GB_512M 72_REG_ECC_0 70 VIRTIUM VL33B5168F F8S DIMM_DDR3 1066_4GB_512M 72_REG_ECC_0 70 VIRTIUM VL33B5663F F8S H DIMM DDR3 1066 2GB256M...

Page 49: ...sing your thumbs 2 Eject partially the memory module using the connector latches while applying some pressure on the top to avoid the full removal of the modules 3 Fully Reseat the modules in the conn...

Page 50: ...nnector USB 2x Stacked J10 Two stacked USB connectors Serial Port COM1 J12 RJ 45 Serial Port connector DDR3 Memory Sokcets J13 J18 Memory Sockets SynchronisationClcocks Update Channel J20 USB Flash Dr...

Page 51: ...figured properly 3 Carefully align the PCB edges in the bottom and top card guide 4 Insert the board in the system until it makes contact with the backplane connectors 5 Using both ejector handles eng...

Page 52: ...stalling the RTM8050 To install the RTM 1 Remove the filler panel of the slot 2 Ensure the board is configured properly 3 Carefully align the PCB edges in the bottom and top card guide 4 Insert the bo...

Page 53: ...Chapter 4 Hardware Management www kontron com 4 1 Hardware Management Overview 38 4 2 Hardware Management Functionality 38 4 3 IPMC 40...

Page 54: ...ent oriented link within a Shelf is a two way redundant implementation of the Intelligent Platform Management Bus IPMB IPMB is based on the inter integrated circuit I2C bus and is part of the IPMI arc...

Page 55: ...ed to go through the ShMC 4 2 1 3 IPMC System Event Log The Kontron IPMC implementation includes a Local System Event Log device as specified in the Section 31 of IPMI 2 0 The local System Event Log i...

Page 56: ...O O Yes Warm Reset 20 3 App 03h O O No Get Self Test Results 20 4 App 04h M M Yes Manufacturing Test On 20 5 App 05h O O Yes Set ACPI Power State 20 6 App 06h O O Yes Get ACPI Power State 20 7 App 07h...

Page 57: ...3Fh O O No Set Channel Access 22 22 App 40h O O Yes Get Channel Access 22 23 App 41h O O Yes Get Channel Info 22 24 App 42h O O Yes Set User Access 22 26 App 43h O O Yes Get User Access 22 27 App 44h...

Page 58: ...M O Yes Chassis Control 28 3 Chassis 02h O M O Yes Chassis Reset 28 4 Chassis 03h O O No Chassis Identify 28 5 Chassis 04h O O No Set Chassis Capabilities 28 7 Chassis 05h O O No Set Power Restore Po...

Page 59: ...owledge 30 8 S E 17h O O No IPMI Spec section NetFn CMD IPMI BMC req Carrier IPMC req Kontron support on IPMC Sensor Device Commands O M Get Device SDR Info 35 2 S E 20h O M Yes Get Device SDR 35 3 S...

Page 60: ...M No Get SDR 33 12 Storage 23h M M No Add SDR 33 13 Storage 24h M O M No Partial Add SDR 33 14 Storage 25h M O M No Delete SDR 33 15 Storage 26h O O No Clear SDR Repository 33 16 Storage 27h M O M No...

Page 61: ...ort 02h O M O M Yes Suspend BMC ARPs 23 3 Transport 03h O M O M Yes Get IP UDP RMCP Statistics 23 4 Transport 04h O O Yes IPMI Spec section NetFn CMD IPMI BMC req Carrier IPMC req Kontron support on I...

Page 62: ...ron support on IPMC AdvancedTCA PICMG 3 0 Table M Get PICMG Properties 3 11 PICMG 00h M Yes Get Address Info 3 10 PICMG 01h M Yes Get Shelf Address Info 3 16 PICMG 02h O Yes Set Shelf Address Info 3 1...

Page 63: ...G 1Eh M Yes FRU Inventory Device Lock Control 3 42 PICMG 1Fh M No FRU Inventory Device Write 3 43 PICMG 20h M No Get Shelf Manager IP Addresses 3 36 PICMG 21h M No Get Shelf Power Allocation 3 85 PICM...

Page 64: ...s the Sensor Device Commands to gather this information Thus commands such as Get Device SDR Info and Get Device SDR which are optional in the IPMI specification are mandatory in AdvancedTCA systems M...

Page 65: ...1 5 table 36 3 Sensor type code 12h for sensor definition 5 Temp 48V A Feed Threshold DC Feed A Input Temperature Degrees Sensor type 01h temperature Event Reading type code 01h threshold based see IP...

Page 66: ...ure Event Reading type code 01h threshold based see IPMI v1 5 section 29 13 3 for threshold based event 19 Temp DIMM 2 Threshold DIMM 2 Temperature Degrees Sensor type 01h temperature Event Reading ty...

Page 67: ...type code 01h threshold based see IPMI v1 5 section 29 13 3 for threshold based event 33 Vcc 1 8V SUS Threshold Voltage on board 1 8V suspend management power supply Volts Sensor type 02h voltage Eve...

Page 68: ...shold based see IPMI v1 5 section 29 13 3 for threshold based event 48 Vcc Vddq Threshold Voltage on board Vddq payload power supply Volts Sensor type 02h voltage Event Reading type code 01h threshold...

Page 69: ...sed see IPMI v1 5 table 36 3 Sensor type code 08h for sensor definition 63 Fuse Earl B Feed Discrete Fuse presence and fault detection on Early 48V supply B Sensor type 08h Power Supply Event Reading...

Page 70: ...MI v1 5 table 36 3 Sensor type code 23h Watchdog 2 for sensor definition 80 CLK3 Control Discrete Clock Resource Sensor Sensor type D0h Kontron OEM Clock Resource Control Sensor Event Reading type cod...

Page 71: ...ation Agent FRU2 Data Error Detection Sensor type C5h OEM Kontron FRU Info Agent Event Reading type code 0Ah Generic Discrete offset 6 8 are used see OEM table Sensor type code C5h Kontron OEM FRU Inf...

Page 72: ...r firmware diagnostic Sensor type C0h Kontron OEM Firmware Info Event Reading type code 70h Kontron OEM Internal Diagnostic see OEM table Sensor type code C0h Kontron OEM Firmware Info for sensor defi...

Page 73: ...Vcc 1 1V 41 Vcc 1 2V 42 Vcc 1 5V 43 Vcc 1 8V 44 Vcc 3 3V 45 Vcc 5V 46 Vcc 2 5V REF 47 Vcc 1 8V CPU 48 Vcc Vddq 49 Vcc 48V A Feed 50 Vcc 48V B Feed 51 Feed A B Status 58 Fuse Pres A Feed 59 Fuse Pres...

Page 74: ...oard Manufacturer type length Calculated Board Manufacturer KONTRON Board Name type length Calculated Board Name AT8050 Board Serial Number type length Calculated Board Serial Number 10 digits serial...

Page 75: ...ated Language code 0x19 Product Manufacturer type length Calculated Product Manufacturer KONTRON Product Name type length Calculated Product Name AT8050 Product Part Number type length Calculated Prod...

Page 76: ...2 01h PICMG 3 0 Base Interface 10 100 1000 BASE T Link Designator Bits 11 0 102h Base Interface Channel 2 Port 0 Link Descriptor 00102F41h Link Grouping ID Bits 31 24 0h Single Channel link Link Type...

Page 77: ...l link Link Type Extension Bits 23 20 0h Fixed 1000Base BX Link Type Bits 19 12 02h PICMG 3 1 Ethernet Fabric Interface Link Designator Bits 11 0 142h Fabric Interface Channel 2 Port 0 Link Descriptor...

Page 78: ...llowing table Table 4 25 Record s content Field Value Record Type ID C0h Record format version 02h Record Length Calculated Record Checksum Calculated Header Checksum Calculated Manufacturer ID 00315A...

Page 79: ...82576EB NC front rear Point to Point Port Descriptor 004002h Reserved Bits 23 18 0h Local Port Bits 13 17 2h Remote Port Bit 12 8 0h Remote Resource ID Bits 7 0 02h Intel ICH Sata Controller Point to...

Page 80: ...Port Bits 13 17 8h Remote Port Bit 12 8 8h Remote Resource ID Bits 7 0 04h Carrier Device 4 Fabric Channel 1 via OnBoard Switch Point to Point Port Descriptor 012805h Reserved Bits 23 18 0h Local Port...

Page 81: ...t Descriptor 004285h Reserved Bits 23 18 0h Local Port Bits 13 17 2h Remote Port Bit 12 8 2h Remote Resource ID Bits 7 0 85h AMC Site 5 AMC B1 Point to Point Port Descriptor 006385h Reserved Bits 23 1...

Page 82: ...Port 3 Point to Point Port Descriptor 018102h Reserved Bits 23 18 0h Local Port Bits 13 17 Ch Remote Port Bit 12 8 1h Remote Resource ID Bits 7 0 02h Carrier Device 2 Intel ICH SATA Controller Point t...

Page 83: ...Channel 0 Lane0 1 2 3 AMC Link Descriptor FE00202f00h Reserved Bits 39 34 3Fh AMC Asymmetric Match Bits 33 32 02h Provides a Secondary PCI Express Port Link Grouping ID Bits 31 24 00h Single Channel L...

Page 84: ...rovides a Secondary PCI Express Port Link Grouping ID Bits 31 24 00h Single Channel Link AMC Link Type Extension Bits 23 20 03h Gen2 SSC AMC Link Type Bits 19 12 02h AMC 1 PCI Express AMC Link Designa...

Page 85: ...served Bits 39 34 3Fh AMC Asymmetric Match Bits 33 32 02h Provides a Secondary PCI Express Port Link Grouping ID Bits 31 24 00h Single Channel Link AMC Link Type Extension Bits 23 20 02h Gen2 NO SSC A...

Page 86: ...e 1 Port Number Bits 9 5 1Fh Lane 0 Port Number Bits 4 0 00h AMC Channel Descriptor FFFFE1h Reserved Bits 23 20 0Fh Lane 3 Port Number Bits 19 15 1Fh Lane 2 Port Number Bits 14 10 1Fh Lane 1 Port Numb...

Page 87: ...ne 0 Port Number Bits 4 0 00h AMC Channel Descriptor FFFFE1h Reserved Bits 23 20 0Fh Lane 3 Port Number Bits 19 15 1Fh Lane 2 Port Number Bits 14 10 1Fh Lane 1 Port Number Bits 9 5 1Fh Lane 0 Port Num...

Page 88: ...Number Bits 14 10 1Fh Lane 1 Port Number Bits 9 5 1Fh Lane 0 Port Number Bits 4 0 007h AMC Channel Descriptor FFFFE8h Reserved Bits 23 20 0Fh Lane 3 Port Number Bits 19 15 1Fh Lane 2 Port Number Bits...

Page 89: ...AMC Channel Descriptor FFFFE7h Reserved Bits 23 20 0Fh Lane 3 Port Number Bits 19 15 1Fh Lane 2 Port Number Bits 14 10 1Fh Lane 1 Port Number Bits 9 5 1Fh Lane 0 Port Number Bits 4 0 07h AMC Channel...

Page 90: ...PICMG Record ID 19h AMC Point To Point Connectivity Record Record Format Version 00h OEM GUID Count 1h OEM GUID Id 0 471C5D14 2AE7 42B9 A9B0 0628546B42CC OEM Module Serial Console Interconnect Record...

Page 91: ...4 34 Carrier Clock Point to Point Connectivity Record Table OnBoard Clock Device Clock Resource Id PCIe Clock Generator 0 Clock Multiplexer 1 Field Value Description Record Type ID C0h Record format v...

Page 92: ...x80 7 6 10b Backplane clock 5 4 0h reserved 3 0 0h Point to Point Clock Connection descriptor Local Clock Id 0x03 On Carrier Clock Id 3 Remote Clock Id 0x05 CLK2B Remote Clock Resource Id 0x80 7 6 10b...

Page 93: ...4 TCLKD Remote Clock Resource Id 0x45 7 6 01b AMC 5 4 0h reserved 3 0 AMC Site Number 5 AMC B1 Field Value Description Record Type ID C0h Record format version 02h Record Length Calculated Record Chec...

Page 94: ...ier device 5 4 0h reserved 3 0 01h On Carrier Device 1 Clock Multiplexer Clock Configuration Descriptor Count 0x0A Clock Configuration Descriptors Clock Id 0x00 Receiver input from CLK1A Clock Control...

Page 95: ...ct Clock Descriptors Count m 0x02 Direct Clock Descriptors Count n 0x00 Indirect clock Descriptor Features 0x02 7 2 0h reserved 1 1b Connected through PLL 0 0b Clock Receiver Dependent ClockId 6 Featu...

Page 96: ...Source Dependent ClockId 1 Features 0x03 7 2 0h reserved 1 1b Connected through PLL 0 1b Clock Source Dependent ClockId 2 Features 0x03 7 2 0h reserved 1 1b Connected through PLL 0 1b Clock Source De...

Page 97: ...erved 1 1b Connected through PLL 0 0b Clock Receiver Dependent ClockId 5 Direct clock Descriptor none Clock Id 0x09 Receiver input from TCLKD Clock Control 0x01 7 1 0h reserved 0 1b Activated by Appli...

Page 98: ...so be separated Packaging the images together allows to upgrade all the components using only one upgrade instruction Moreover it ensure all components upgraded are compatible The following table give...

Page 99: ...83 AT8050 Chapter 5 Chapter 5 Software Setup www kontron com 5 1 AMI BIOS Setup Program 84 5 2 Boot Utilities 113 5 3 Console Redirection VT100 Mode 114...

Page 100: ...system When you get the following messages hit DEL key to enter SETUP AMIBIOS C 2010 American Megatrends Inc KONTRON AT8050 BIOS Version 3 00 C American Megatrends Inc 64 3047 009999 00101111 031710 T...

Page 101: ...m However the values for these options should be changed only if the user has a full understanding of the timing relationships involved Note All options in Bold are the default settings WARNING BIOS V...

Page 102: ...e help text for the selected field It updates as you move the cursor to each field Menu Selection Description Main Use this menu for basic system configuration Advanced Use this menu to set the Advanc...

Page 103: ...elp text BIOS Version 8 00 15 Displays the AMI BIOS version N A display only Build Date MM DD YY Display the BIOS build Date N A display only BIOS ID 5007_XYY Display the BIOS ID this include the BIOS...

Page 104: ...ize AT8050 DIMM electrically closest to CPU filled last N A display only Channel 2 DIMM 0 Memory Size X GB Displays Channel 2 DIMM 0 memory size AT8050 DIMM electrically farthest to CPU filled first D...

Page 105: ...D Value Limit Disabled Enabled Enable for legacy operating systems does not support CPUID function 3 Processor Virtualization Enabled Disabled Allow virtualization to be enable need supported OS Enabl...

Page 106: ...the controller is using only legacy resources i e IRQ 14 15 compatible or with memory resources only Enhanced Only shows when SATA 1 is configure in IDE mode AHCI allows advanced SATA features such a...

Page 107: ...ce type Hard disk Display only Vendor N A Display the vendor string of the disk Display only Size N A Display the size of the disk Display only Ultra DMA N A Display the current speed of the drive Dis...

Page 108: ...es AHCI Port2 N A Selects sub menu While entering setup BIOS auto detects the presence of IDE devices This displays the status of auto detection of IDE devices Feature Option Description Help text Dev...

Page 109: ...nt Log Enter View all unread events in the Event Log View all unread events in the Event Log Mark Events as read Enter Mark all unread events as read in the Event Log Mark all unread events as read in...

Page 110: ...Expansion ROM on the face plate can be enabled disabled If disabled remote LAN boot via the management ports on the face plate is not available to boot the system Enabled Initializes Management Ports...

Page 111: ...As a Transmitter the Function must not generate TLPs exceeding the set value Set Maximum Payload of PCI Express Device or allow System BIOS select the value Extended Tag Field Auto Disabled Enabled E...

Page 112: ...SB Mass Storage Class Devices Feature Option Description Help text Device 1 6 Mass Storage Device identification Emulation Type for each devices Auto Floppy Forced FDD Hard Disk CDROM If Auto USB devi...

Page 113: ...ion N A Display Current NB revision ID Show only Current QPI Frequency N A Display Current QPI frequency speed in GT s Show only Intel QuickData Technology DMA Enabled Disabled Enable special setting...

Page 114: ...full access to the BIOS Setup utility No Access Prevents user access to the setup utility View Only Allows read only user access to the setup utility i e none of the fields can be changed Limited Allo...

Page 115: ...ts sub menu Lists available hard disk drives in priority order Removable Drives N A Selects sub menu Lists available removable disk drives in priority CD DVD Drives N A Selects sub menu Lists availabl...

Page 116: ...bite If value is set to Keep booting the boot sequence keep the failling device and boot from the next Reset sequence Boot sequence is reset after a good start from a device Keep booting Boot sequenc...

Page 117: ...he boot priority of the available devices Select the boot device with UpArrow or DownArrow key Press Enterto set the selection as the intended boot device Feature Option Description Help text 1st Driv...

Page 118: ...e boot priority of the available devices Select the boot device with UpArrow or DownArrow key Press Enterto set the selection as the intended boot device Feature Option Description Help text 1st Drive...

Page 119: ...t the boot device with UpArrow or DownArrow key Press Enterto set the selection as the intended boot device Feature Option Description Help text 1st Drive Varies Specifies the boot priority of any oth...

Page 120: ...Headless operation mode through ACPI Select serial port for console redirection Serial Port 1 I O address 3F8 IRQ4 Displays the hardware address of the COM 1 port N A display only Serial Port 2 I O ad...

Page 121: ...routing messages between channels The channel number assignments are described in IPMI Specification 2 0 table 6 1 Enter Active LAN Channel Number for Set LAN Configuration Command Feature Option Desc...

Page 122: ...ter Selector 06 The parameter selector assignments are described in IPMI Specification 2 0 table 23 4 Selector 06 Subnet Mask N A display only Channel Number 01 or 02 Each interface has a channel numb...

Page 123: ...hiden when DHCP source is selected Enter Gateway IP Address indecimal in the form of XXX XXX XXX XXX XXX less than 256 and in decimal only Feature Option Description Help text LAN Parameter Selector 2...

Page 124: ...y configuration stored in IPMI NVRAM for IPMI LAN N A display only Feature Option Description Help text BIOS POST Timeout Disabled 60 120 150 300 600 Configures the BIOS POST IPMI HW watchdog timeout...

Page 125: ...Board Serial Number Varies Displays the CPU blade serial number N A display only Board Part Number Varies Displays the CPU blade part number N A display only Chassis Slot 1 16 Displays the current ch...

Page 126: ...notation N A display only Maintenance Revision Varies Displays Maintenance revision This field correspond to the implementation specific auxiliary information from IPMI Get Device ID Command byte 15 T...

Page 127: ...press Routting N A Management LAN Setting Disabled Front Panel AMC 2 Module RTM Fabric Interface Route Management LAN to the selected destination Selects where the Management LAN ports are routed Warn...

Page 128: ...nable AMC PCI Express based on e keying Warning Re insert the blade after changing settings AMC PCI Express State Disabled Auto Display actual AMC PCI Express N A Feature Option Description Help text...

Page 129: ...TM must be present 2 Press F3 to select the boot device 3 Press CTRL C during the execution of the option ROM Feature Option Description Help text Exit Saving Changes N A Saves modified settings into...

Page 130: ...erent device each time you boot during POST by selecting your boot device in the Boot device F11 or F3 from a Console Redirection terminal 5 3 Console Redirection VT100 Mode The VT100 operating mode a...

Page 131: ...al connections such as Windows Server 2003 Emergency Management Services EMS AMIBIOS8 Serial Redirection supports these key sequences under two configurations Terminal Type setup question is set to VT...

Page 132: ...116 AT8050 Chapter 6 Thermal Considerations www kontron com 6 1 Thermal Monitoring 117...

Page 133: ...he lowest possible thermal resistance Moreover the heat sinks were specifically designed to use forced airflow as found in ATCA systems 6 1 2 Temperature Sensors The AT8050 is equipped with 21 tempera...

Page 134: ...low is the list of temperature sensors with their respective thresholds Table 6 1 Temperature Sensors Thresholds Sensor ID Lower Thresholds Upper Thresholds Minor Major Critical Minor Major Critical T...

Page 135: ...ty of your chassis is known the PQ curve can help determine the ambient room temperature setpoint that should be used for optimal operation If you are using various models of ATCA blades into the same...

Page 136: ...thermal profile to make sure the MTBF values are respected The CPU usage will influence the temperature that the case can handle Refer to the figure below for more details Figure 6 3 CPU Thermal Prof...

Page 137: ...ber Channel BIOS 18KB 64KB address may vary E0000 FFFFF System BIOS 100000 PCI Memory DRAM available 1MB to top of DRAM System BIOS See detailed map to the right 0 622KB DRAM Optional ROM free Video D...

Page 138: ...time clock 080 09F DMA Page Register 0A0 0BF Interrupt Controller 2 0C0 0DF DMA Controller 2 0F0 0F1 0F8 0FF Math Coprocessor 1F0 1F7 3F6 Primary IDE 170 177 376 Secondary IDE 378 37F Parallel Port Us...

Page 139: ...onnect Routing and Protocol Layer Registers Port 0 rev 10 IOH 00 11 8086 3427 0 Intel Corporation QuickPath Interconnect Physical and Link Layer Registers Port 1 rev 10 IOH 00 11 8086 3428 1 Intel Cor...

Page 140: ...Network Connection I82576 on Base Interface 02 00 8086 10c9 0 Intel Corporation 82576 Gigabit Network Connection I82576 on Base Interface 03 00 8086 10d8 0 Intel Corporation 82599 Gigabit Network Con...

Page 141: ...A 5 AT8050 www kontron com A 4 Telco Clock Clock Circuit Overview...

Page 142: ...ce is manual Write the selection in bit SEL_REF SEL_REFA SEL_REFM On a read return the reference automatically selected by the CPLD 0 REF0 is the reference used by the PLL i e CLKA 1 REF1 is the refer...

Page 143: ...to BP_REF failed with current OOR setting 1 failed clock 0 passed clock TIE_CLR Timing Interval Error adjustement 1 normal mode 0 adjust phase to match reference MODE PLL operating mode 1 freerun mod...

Page 144: ...e this bit is forced to 0 when the AMC is in fault or removed 1 drive AMC B1 clock TCLKA 0 don t drive AMC B1 TCLKA Note If the clock source of the PLL is 19 44MHz the phase of this clock is unrelated...

Page 145: ...ed for selection of the AMC that provides the clock for backplane CLK3A B Applicable tot boards with two AMCs 0 use AMC B1 1 use AMC B2 CLK3FRQ Backplane CLK3A frequency 0 copy AMC TCKLB to backplane...

Page 146: ...e on reference 0 on the PLL This is basically a short failure detection that the IPMC would otherwise miss Use Telco 1 to read the current state To Clear this bit write a 1 in it The bit will be clear...

Page 147: ...s J2 Connector Description J2 PostCodes J5 AMC J8 Ethernet Port 0 J9 Ethernet Port 1 J10 USB 2x Stacked J12 Serial Port COM1 J20 Synchronisation Clocks Update Channel J22 USB Flash Drive J23 Base Inte...

Page 148: ...RxD6 B102 RxD10 B145 RxD17 B18 12V B60 RxD6 B103 RxD10 B146 GND B19 GND B61 GND B104 GND B147 TxD18 B20 RxD1 B62 TxD6 B105 TxD11 B148 TxD18 B21 RxD1 B63 TxD6 B106 TxD11 B149 GND B22 GND B64 GND B107 G...

Page 149: ...ENABLE B83 PS0 GND B126 RxD14 B169 TDI N C B42 12V B84 12V B127 RxD14 B170 GND B85 GND B128 GND Signal Pin Pin Signal BI_DA 1 5 BI_DC BI_DA 2 6 BI_DB BI_DB 3 7 BI_DD BI_DC 4 8 BI_DD Signal Pin VCC 1 D...

Page 150: ...C 8 Tx0 14 N C Tx0 14 N C Rx0 14 N C Rx0 14 N C Tx1 14 N C Tx1 14 N C 9 Tx2 13 N C Tx2 13 N C Rx2 13 N C Rx2 13 N C Tx3 13 N C Tx3 13 N C 10 Tx0 13 N C Tx0 13 N C Rx0 13 N C Rx0 13 N C Tx1 13 N C Tx1...

Page 151: ...DC1 BI_DC1 6 BI_DA2 DI_DA2 BI_DB2 BI_DB2 DI_DC2 BI_DC2 7 N C N C N C N C N C N C 8 N C N C N C N C N C N C 9 N C N C N C N C N C N C 10 N C N C N C N C N C N C Pin ROW G ROW H ROW AB ROW CD ROW EF ROW...

Page 152: ...7 SAS_0_TX SAS_0_TX SAS_0_RX SAS_0_RX SAS_1_TX SAS_1_TX 8 GBE_TX1 GBE_TX1 GBE_RX1 GBE_RX1 GBE_TX2 GBE_TX2 9 PE6_TX PE6_TX PE7_RX PE7_RX PE5_TX PE5_TX 10 PE4_TX PE4_TX PE5_RX PE5_RX PE7_TX PE7_TX Pin...

Page 153: ...2 7 8 HA3 HA4 9 10 HA5 HA6 11 12 HA7 P SCL_A 13 14 SDA_A SCL_B 15 16 SDA_B MT1_TIP N C 17 18 MT2_TIP N C RING_A N C 19 20 RING_B N C MT1_RING N C 21 22 MT2_RING N C RRTN_A N C 23 24 RRTN_B N C SHELF_G...

Page 154: ...s and cache first 8MB Set stack D5 Bootblock code is copied from ROM to lower system memory and control is given to it BIOS now executes out of RAM D6 Both key sequence and OEM specific method is chec...

Page 155: ...Init Start Disable Cache Init Local APIC C1 Set up boot strap processor Information C2 Set up boot strap processor for POST C5 Enumerate and set up application processors C6 Re enable cache for boot s...

Page 156: ...if ACPI is supported 8E Program the peripheral parameters Enable Disable NMI as selected 90 Late POST initialization of system management interrupt A0 Check boot password if installed A1 Clean up wor...

Page 157: ...on for all BUSes The lower nibble Y indicates the BUS on which the different routines are being executed Y can be from 0 to 5 Checkpoint Description 2A Initialize different buses and perform the follo...

Page 158: ...ces 4 ISA PnP devices 5 PCI devices C 4 Memory Initialization ERROR Code Checkpoint Description E8 Memory Error No memory installed EA Memory Error DDR3 Initialisation EB Memory Error Memory test ED M...

Page 159: ...ad impact on your board To update your board from the update CD boot from the CD and follow the instructions provided in the AT8050 Update CD User guide provided with the CD image file A remote update...

Page 160: ...t ca kontron com EMEA support kom kontron com Or at the following address North America EMEA Kontron Canada Inc Kontron Modular Computers GmbH 4555 Ambroise Lafortune Sudetenstrasse 7 Boisbriand Qu be...

Page 161: ...the serial number of the defective product and a description of the problem E 2 When Returning a Unit In the box you must include the name and telephone number of a contact person in case further expl...

Page 162: ...A Advanced Telecommunications Computing Architecture BBS BIOS Boot Specification BI Base Interface Backplane connectivity defined by the ATCA BIOS Basic Input Output System BMC Base Management Control...

Page 163: ...be replaced by a user in the field Not all FRUs are hot swappable FWH FirmWare Hub Boot flash connected to the LPC bus containing BIOS FW Gb Gigabit GB Same as GByte GigaByte GByte Same as GB GigaByt...

Page 164: ...evice MB MegaByte MCH Memory Controller Hub MHz MegaHertz MMC Module Management Controller MMCs are linked to the IPMC NC Not Connected OOS Out Of Service OS Operating System PHY PHYsical layer Generi...

Page 165: ...MD is Single Instruction Multiple Data SSE3 Streaming SIMD Extension 3 SIMD is Single Instruction Multiple Data SSH Secure SHell A network protocol that allows data to be exchanged over a secure chann...

Reviews: