886LCD-M Family
KTD-00474-E
Public User Manual
Date: 2005-05-24
Page
47 of 78
4.17 Feature Connector (FEATURE)
Note
Pull
U/D
Ioh/Iol
Type
Signal
PIN
Signal
Type
Ioh/Iol
Pull
U/D
Note
2
100K/
-
I
INTRUDER# 1 2
GND
PWR
-
-
EXT_ISAIRQ#
3 4 EXT_SMI#
I
PWR_OK 5
6 SB5V
PWR
-
-
-
-
PWR
+3V3 7
8
EXT_BAT
PWR
-
-
-
-
PWR
+5V 9
10
GND
PWR
-
-
IOT
GPIO0 11
12
GPIO1
IOT
IOT
GPIO2 13
14
GPIO3
IOT
IOT
GPIO4 15
16
GPIO5
IOT
IOT
GPIO6 17
18
GPIO7
IOT
-
-
PWR
GND 19
20
FAN3OUT
FAN3IN 21
22
+12V
PWR
-
-
TEMP3IN 23
24
VREF
-
-
PWR
GND 25
26
IRRX
IRTX 27
28
GND
PWR
-
-
1
2K7/
SMBC 29
30
SMBD
2K7/
1
Note 1: Pull-up to 3V3 supply
Note 2: Pull-up to RTC-Voltage
Note: For Engineering build, 26 pin header is mounted, causing INTRUDER#, GND, SMBC and SMBD
signals (pin 1, 2, 29, 30) to be unavailable.
Signal
Description
INTRUDER#
INTRUDER, may be used to detect if the system case has been opened. This signal’s
status is readable, so it may be used like a GPI when the Intruder switch is not needed.
EXT_ISAIRQ#
EXTernal ISA IRQ, (active low input) can activate standard AT-Bus IRQ-interrupt.
EXT_SMI#
External SMI, (active low input) signal can activate SMI interrupt.
PWR_OK
PoWeR OK, signal is high if no power failures is detected.
SB5V StandBy
+5V
supply.
+3V3
EXT_BAT
(EXTernal BATtery) the + terminal of an external primary cell battery can be connected
to this pin. The – terminal of the battery shall be connected to GND, for instance pin 10.
The on board battery circuit makes sure that the external battery will not be recharged.
The external battery can be used with or without the on board battery installed.
The external battery voltage shall be in the range: 2.5 - 4.0 V DC.
+5V
GPIO0..7
General Purpose Inputs / Output. These Signals may be controlled or monitored through
the use of the KONTRON API (Application Programming Interface) available for Win98,
WinXP, WinNT, and Win2000.
FAN3OUT
FAN 3 speed control OUTput. This analogue voltage output controls the Fan’s speed.
FAN3IN
FAN3 Input. 0V to +5V amplitude Fan 3 tachometer input.
+12V
TEMP3IN
Temperature sensor 3 input.
VREF
Voltage REFerence, reference voltage to be used with TEMP3IN input.
IRRX
IR Receive input (IrDA 1.0, SIR up to 1.152K bps)
IRTX
IR Transmit output (IrDA 1.0, SIR up to 1.152K bps)
SMBC SMBus
Clock
signal
SMBD SMBus
Data
signal