Konig SEC-CON22 Manual Download Page 8

 

3.6.3 Pattern 

design path setup

SET

+

+

PATTERN

+path+

SET

+ 0 +

  PATTERN

 

Press

SET

key

input the number of design scan

1-4

press

PATTERN

key

enter the path setup state

when ending    press 

SET

key first

then press

0

key

then 

PATTERN

key

 

starting the design scan

N

+

PATTERN

input the design scan number

1-4

press

PATTERN

key to 

starting

 

 

 

3.6.4 Cruise 

starting

 

N

  +

TOUR 

/

TOUR

  cruise number first 

then 

TOUR

key

starting the cruise

 

Direct press the 

TOUR

  key when the system only have one cruise .

 

 

3.7 Call Dome main menu   

9

+

5

+

PRESET

Input 95

press

PRESET

key

  aim Dome

menu will display on the monitor

 

 

3.8 Matrix control

 

3.8.1 switch dome orderly 

The matrix can connect the 16pcs High Speed Dome. All the information like the Series NO, Data and time will 

display on the monitor while switch the speed dome camera. 

PREV

: switch to previous camera

Press 

PREV

2 Sec

it will keep switch till the whole 16 high speed dome. Press

Stop

to stop the switching.

NEXT

back 

forward. Press

NEXT

it will switch to the next camera; Press

NEXT

2 Sec, it will keep back forward switch 

till the final 16

th

 camera. You can use the 

Stop

key to stop the operate 

 

3.8.2 Call matrix main menu   

SHIFT

+

SET

  Call the main menu, the menu will display on the object monitor. How to use the keyboard 

Setting the matrix? Pls refers the matrix operate manual. 

 

3.8.3 Confirm after program 

ENTER

after the matrix is    programmed, press

ENTER

,

 reflects confirm after program. 

As for the detail program, please refer to the matrix operation manual. 

 

3.8.4 

Change object monitor

 

N

+

MON

Input the monitor ID, then press MON the image and the menu of the dome that you   

controlled by keyboard will display in the object monitor 

 

4

Keyboard menu control 

Keyboard parameter set up 

Turn  on  the  power  and  press  the

MENU

,  the  system  information  will  display  on  the  screen,  like  the 

picture(4.1-1), press again the system information will disappear. You can do all the keyboard operation while in 

the standby condition or the system information display condition. 

Press

MENU

and hold on 2 sec, you will enter the main menu as the picture (4.1.1-1)show. All the menu

 

setting need enter the main menu first,and use the correspond NO or the 

Joy calibrate

 to move UP and DOWN.

 

While you find the item you need, move the joystick RIGHT or LEFT to enter the menu. 

Summary of Contents for SEC-CON22

Page 1: ...1 SEC CON22 Speed Dome Controller ...

Page 2: ... Pattern 7 3 6 4 Cruise 8 3 7 Call dome main menu 8 3 8 Matrix Control 8 3 8 1 Switch dome in order 8 3 8 2 Call matrix main menu 8 3 8 3 Confirm after program 8 3 8 4 Change object monitor 8 4 Keyboard control 8 4 1 Keyboard parameter setup 9 4 1 1Keyboard ID setup 9 4 1 2 Keyboard baud rate setup 10 4 1 3 Navigation key adjust 10 4 1 4 Display Keyboard information 11 4 2 Dome setup 11 4 2 1 Pre ...

Page 3: ...nd a keyboard can connect 31 domes at most in the direct control mode can be compatible with all kinds of protocols can control the Iris Focus and Zoom can set and call the preset run the scanning the pattern and the tour can control the matrix and through which can control the dome indirectly equipped with the 3D Joystick and a LCD screen The LCD can display the current operation order the contro...

Page 4: ... controls the dome directly RS485 A B can connect with DVR or other keyboards when the keyboard controls the dome by matrix 2 2 Direct connect with Dome Keyboard connect the Dome wit RS485 The RS485 interface of the Dome is on the commutator of the Dome Press the metal button in the hanging frame open the commutator will find a 4bit power jack follow the surface instruction to find RS485 A B follo...

Page 5: ...d of the main keyboard should be 1 and baud rate should be 9600bps as figure 2 3 1 Figure 2 4 1 Caution 1 the max quantity of master equip and be charged equip controlled by a RS485 bus is so when use the keyboard to control direct the max dome quantity is 3 2 max quantity keyboard in a system is 4 also the 4 keyboards should be different ID matrix Dome1 Dome2 Figure 2 4 2 Keyboard 1 Keyboard 2 Ke...

Page 6: ...ll the info will be displayed on LCD screen Attention 3 2 LCD display screen LCD screen display contents aim dome aim monitor and baud rate etc And at the end of the content will show the current operation order and the states of joystick as follows figure show When operation LCD back light will on and will be off 10s after the operation Figure 3 1 2 Camera Monitor Protocol Baud rate Figure 3 1 1 ...

Page 7: ...rial number of the Dome Press CAM key to amend the add of the aim dome 3 5 Dome lens control Zoom Users can control the zoom by rotating the joystick Focus Press FAR key focus for far objects Press NEAR key focus for vicinity objects Normally Zoom and focus will be adjusted automaticly by the dome and with the FAR NEAR to realize the manual zoom and focus Iris Press OPEN key manual Iris accretion ...

Page 8: ...rward switch till the final 16th camera You can use the Stop key to stop the operate 3 8 2 Call matrix main menu SHIFT SET Call the main menu the menu will display on the object monitor How to use the keyboard Setting the matrix Pls refers the matrix operate manual 3 8 3 Confirm after program ENTER after the matrix is programmed press ENTER reflects confirm after program As for the detail program ...

Page 9: ...yboard setting as LCD Picture4 1 1 2 Picture 4 1 1 2 3 Press 1 again will show the picture Picture4 1 1 3 Picture4 1 1 3 4 Press 1 to select the ID Setting Picture4 1 1 4 Picture 4 1 1 4 Use the Number key to select the camera ID in the range 1 64 And then press the Enter to save the screen will display Success as picture 4 1 1 5 Picture4 1 1 5 1 Keyboard setup 2 Dome setup 3 Protocol select 4 Exi...

Page 10: ... Joystick calibrate When the joystick at midpoint position pls enter the menu to enter the joystick calibrate Item When calibrating the joystick must be in a natural state Enter the main menu LCD will display picture4 1 1 1 2 Press 1 to select the keyboard setting as LCD Picture4 1 1 2 3 2 Press 3 into joystick calibrate as LCD Picture4 1 3 1 Picture4 1 3 1 Press Enter and the joystick calibrate i...

Page 11: ...Pattern Tour Picture4 2 1 1 Press 1 enter the dome Preset function setting as picture 4 2 1 2 Picture 4 2 1 2 Item 1 Save preset item 2 Show the preset Item 3 delete the preset Press 1 enter the preset you can input the preset NO as picture 4 2 1 3 show Picture 4 2 1 3 After enter the preset menu you can use navigate key control the dome directly and input the preset NO to save as the picture 4 2 ...

Page 12: ...ure 4 2 2 2 show Picture 4 2 2 2 While enter the dome limit setting menu move the dome to the suitable position and press Enter to save and will show Success and back to previous menu Select the item 2 to set the Right limit and do the same as the left limit setting Back to the menu and press 3 to operate the Run Scan Warning Under commonly mode Dome can not control by operate the keys and move th...

Page 13: ...1 show And then press 4 enter the tour setting as the picture 4 2 4 1 show Picture 4 2 4 1 After enter the menu you need input the TOUR information the range you can put is 1 6 and press the ENTER confirm Then the mouse will auto skip to the second TOUR setting If first one is ok Users can skip it And it will show the Success and back to the previous menu Select the Item 2 as picture 4 2 4 2 you n...

Page 14: ... 4 3 2 1 According to the user s need select the suitable PROTOCOL and back to the previous menu Picture 4 3 2 1 Enter the menu as picture 4 1 1 1 and press the 5 to exit the menu 5 Appendix 5 1 RS485 Bus Basic Knowledge RS485 Bus Basic Character According to RS485 industrial standards RS485 Bus is of half duplex data transmission cables with characteristic impedance as 120 The maximum load capaci...

Page 15: ...ure 4 1 2 for simple connection But D should not exceed 7m 1 2 3 4 32 Picture 4 1 1 A D B A B 1 2 3 4 32 Picture 4 1 2 Problems in practical use In some circumstances user adopts a star configuration in practical connection The termination resistors must be connected to the two equipments that are father away from each other such as equipment1 and 15 refer to picture 4 1 3 As the star configuratio...

Page 16: ...system setting N CAM High speed dome Input Dome ID press CAM to select object dome Rotate the joystick anti clockwise High speed dome Zoom in Rotate the joystick clockwise High speed dome Zoom out FAR High speed dome Press FAR far focus NEAR High speed dome Press NEAR near focus CLOSE High speed dome Press CLOSE reduce iris OPEN High speed dome Press OPEN increase Iris SET N PRESET High speed dome...

Page 17: ...eed dome Press SET and input0 Press PATTERN to save path N PATTERN High speed dome Input the pattern path 1 4 Press PATTERN to start pattern N TOUR TOUR High speed dome Input the TOUR NO press TOUR or directly press TOUR to start the Tour 9 5 PRESET High speed dome Input 95 and press Preset to call the menu PELCO Matrix Mode SHIFT SET Matrix Press SHIFT and SET to call the matrix menu PREV Matrix ...

Page 18: ...18 ...

Reviews: