background image

26776 Tiltable desktop 
monitor stand

 

INTENDED USE 
- Desktop stand individually adjustable in height and inclination 

for monitors and many other devices of this size 

FEATURES & CAPABILITIES 
- Load-bearing capacity up to 25 kg centered load 
- Solid, flat stand with 4-point felt support and space for cables 
- Functional monitor tray (W x D 230 x 250 mm): 

-

 - Variable angle adjustment up to 12.5° with safety ledge 

-

 - Movable to ensure that the load is centered 

- Variable height adjustment, double reinforced tube combination  
- Data: Height 350 - 450 mm, base 250 x 210 mm, Weight: 4.15 kg

SAFETY NOTES

Thank you for choosing this product. Please read and follow carefully the instructions. They 
inform you about all important steps, that are required for a safe assembly and operation. Please 
keep the instructions for future reference.

A. GENERAL

 

A.

 

- Load-bearing capacity max. 25 kg centered load 

A.

 

- Careful handling required - during all phases of use (

A - F

A.

 

- ACTIVITIES AT THE STAND (change location, extend/retract tube, adjust tray) MUST  

A.

 

-

 ALWAYS BE DONE IN UNLOADED CONDITION (e.g. danger of tipping over) 

A.

 

- Keep unauthorized personnel away from the stand      

A.

 

- Only to be used indoors 

 

B. INSTALLATION NOTES

 

B.

 

- The surface (desktop) must be suitable, i.e. level and load-bearing   

B.

 

- Wear protective gloves during assembly, if needed 

B.

 

- In particular, during assembly do not drop - or crush limbs 

B.

 

- Securely screw components (base, tube combination, joint, tray) together 

 

C. STAND SETUP

 

C.

 

- Please consider the information provided in the SETUP INSTRUCTIONS 

C.

 

- The screw connection between the stand tube and base plate  

C.

 

-

 must be screwed in as far as it will go 

2.1

 

C.

 

- The weight bearing load is not to be placed on the tray until the extension tube  

C.

 

-

 height has been adjusted, i.e. when: - the catch 

4.4

 is always clicked into place; 

C.

 

-

 

height has been adjusted, i.e. when:

 - the clamping screw 

4.5

 has been tightened; 

C.

 

-

 

height has been adjusted, i.e. when:

 - the angle of the tray 

c

 has been adjusted and 

C.

 

-

 

height has been adjusted, i.e. when:

 

-

 the safety nut has been re-tightened 

3

 and 

8

 

C.

 

- Note: initially the load is carefully placed on the tray and held securely.  

C.

 

-

 If the tray tilts, the nuts 

8.4

 have to be tightened. 

C.

 

- The load is to be centered on the tube combination 

12

, anything that is not centered  

C.

 

-

 can have a negative effect on stand stability 

 

D. PRIOR TO USE

 

D.

 

- Prior and after use the stand should undergo visual inspection, to ensure that all  

D.

 

-

 components are there and in working order.

 

D.

 

- Damaged stands may not be used i.e. the stand must be repaired by a qualified  

D.

 

-

 technician.

 

 

E. DURING OPERATION

 

E.

 

Safety during operation is based on: 

E.

 

1. ...FOLLOWING the points listed here under 

A - F

E.

 

2. ...MASTERING the LATERAL FORCES (TIPPING DANGER).  

E.

 

2.

 Lateral forces should be avoided at all costs. It occurs in the following cases: 

E.

 

2.

 

a.

 the stand is tilted (uneven surface) 

E.

 

2.

 

b.

 the load bearing weight is not centered 

E.

 

2.

 

c.

 external shocks such as bumping into the stand, brushing into the stand, wind etc. 

E.

 

2.

 Lateral forces must be prevented by suitable measures. In the case of items

 a. 

E.

 

2.

 and 

b.

, this is done by correct assembly and placement, and in the case of item  

E.

 

2.

 

c.

, possibly by safety measures or by maintaining safety distances for unauthorized  

E.

 

2.

 persons. 

 

E. DISASSEMBLY 

 

E.

 

- First remove the load from the tray - then retract or dismantle the stand

SETUP INSTRUCTIONS

1. COMPONENTS (a-m) 

Please carry out a visual inspection to ensure that all parts are included and, as far as can 
be seen, are OK: 

a

 Base plate with the four feet 

b

 Tube combination cpl.: 

b.1

 base tube, 

b.2

 clamp, 

b.3

 extension tube, 

b.4

 joint 

c

 Tray with 

c.1

 ledge 

Accessories bag: 

d

 countersunk screw M8 x 20 mm - 

e

 caps SW10 - 

f

 washers ø 6.4 mm 

Accessories bag: 

g

 lock nuts M6 - 

h

 caps SW13 - 

i

 wrench SW10/13 - 

k

 Allen key SW5 

Accessories bag: 

m

 rubber pads (4x)

 

 

SETUP 

 

2. STAND 
2.1

 Insert the two pins of the base tube 

b.1

 into the slots of the base plate and connect  

2.1

 both parts using the countersunk screw M8 x 20 mm 

d

. Use the SW5 Allen key 

k

 for  

2.1

 this purpose.  

2.2

 Now set up the stand and carefully place it on the surface. To protect it, the base plate  

2.2

 has 4 feet with a felt pad. Tighten the loosened stand legs again with a socket wrench  

2.2

 (SW8 = M5). 

 

3. MONITOR TRAY

 

3.1

 The tray 

c

 is placed on the joint using the threaded bolt 

b.4

 and screwed together... 

3.2

 ...with the safety nuts 

g

 and the washers ø 6.4 mm 

f

3.2

 To accomplish this, use the SW10 

i

 Allen wrench. In the final step place the caps 

e

.

1. COMPONENTS

2. STAND

3. MONITOR TRAY

KÖNIG & MEYER

 GmbH & Co. KG  

Kiesweg 2, 97877 Wertheim, www.k-m.de 

26776-000-55  Rev.03  03-79-934-00  10/21

M5 / SW8

Summary of Contents for 26776

Page 1: ...tte m ssen die Muttern 8 4 nachgezogen werden C Rohrkombination stets so zentrisch wie m glich belasten 12 da au ermittige C Belastung die Standfestigkeit der Installation beeintr chtigt D VOR DEM BET...

Page 2: ...end Auszugrohr einfahren lassen und 5 4 Fanghaken wieder in die vorgesehene ffnung 5 4 dr cken und in das Rohr einhaken lassen 5 5 Fl gelmutter wieder festziehen MONITOR AUFLAGE PLATTE 6 GUMMIAUFLAGEN...

Page 3: ...lageplatte beide 11 1 Verschraubungen ENTFERNEN 11 1 Zun chst Kappen abziehen 11 1 anschlie end Sicherungsmuttern 11 1 und U Scheiben entfernen 11 1 Dazu Schl ssel SW10 i benutzen 11 2 Ablageplatte c...

Page 4: ...5 x 80 mm Gewicht netto 4 15 kg brutto 4 5 kg F Stativ kippelt bzw steht schief F B Untergrund auf Ebenheit pr fen F B Sockelplatte auf Ebenheit pr fen F B Festsitz der Schraube d an Sockel a und Grun...

Page 5: ...e centered on the tube combination 12 anything that is not centered C can have a negative effect on stand stability D PRIOR TO USE D Prior and after use the stand should undergo visual inspection to e...

Page 6: ...ocess the catch unlocks automatically 5 3 Then let the extension tube retract and 5 4 press the catch into the desired 5 4 groove until it clicks into place 5 5 Re tighten the wing nut MONITOR TRAY 6...

Page 7: ...11 1 REMOVE both screws located 11 1 underneath the tray 11 1 First take off the caps 11 1 then remove the safety nuts 11 1 and washers 11 1 To accomplish this use wrench SW10 i 11 2 Remove tray c 11...

Page 8: ...t 8 4 F Monitor slips F R The safety ledge must be at the bottom 9 if needed disassemble and F R reassemble so that it is on the bottom F R Check monitor for suitability In particular it must be ensur...

Reviews: