(4) Secure the PI-506. (TP screws M4x6: 3 pcs.)

5. Install the wire bundle cover /1 to the PI-506

connector. (Truss screw M4x6 (black): 1 pc.)

6. Install the screw cover on the top front of the Fin-

isher.

7. Install the Finisher on the main body (refer to the

Finisher Installation manual).

8. Plug in the power cord and turn the Main power

switch ON of the main body.

9. Adjusting the spread of the paper-width guide

15JFIXE011SA

Connector

TP screws M4x6

A10YIXC002CA

Front

TP screws M4x6

15JFIXE014SB

Truss screw
M4x6 (black)

Wire bundle cover/1

Screw cover

Step

1. Enter [Service mode].

Note:

Refer to procedures in the Service Manual
to enter into the Serivce Mode.

2. Touch the “Finisher Adjustment” key.
3. Touch the “Cover Sheet Size Adj.” key to

indicate the [Cover sheet tray size adj.
(upper tray)] screen.

4. Set A4S or 8.5/11S paper in the upper

cover-sheet tray.

5. Touch the “Start” key.
6. When adjustment is completed, “Complete”

appears on the message display.

7. Touch the “Next” key to indicate the [Cover

Sheet Tray Size Adj. (Lower Tray)] screen.

8. Set A4S or 8.5/11S paper in the lower cover-

sheet tray.

9. Touch the “Start” key.

10. When adjustment is completed, “Complete”

appears on the message display.

11. Verify that each paper size can be properly

detected.