Konica Minolta DF-704 Installation Manual Download Page 8

E-8

(10) Touch “END.”
(11) Repeat the steps (1) to (6) to check if the value 

of “Avg. Value” falls within the specified range.

(12) Attach the two supplied hinge covers as shown 

in the illustration.

(13) Tighten the mounting screw on the right hinge 

that has been loosened in step (7) using a 
screwdriver.

<Adjusting DF skew (2-side)>

(1) Touch “Skew Measurement.”
(2) Touch “DFSkew(Back).”
(3) Place the chart in the document feeding tray 

(Make sure that the blank surface of the chart 
faces up).

(4) Press the start key.

The measurement result will be displayed.

(5) Repeat operations from steps (3) to (4) four more 

times. (Five times in total)

(6) Check the value of “Avg. Value” on the screen.

Specifications: ±0.5%

Note:

If the value does not fall within the specified range, 
perform the following adjustment.

(7) Open the dual scan document feeder and 

remove the two screws shown in the illustration.

(8) Close the dual scan document feeder.
(9) Remove the front cover.

(10) Loosen the two screws shown in the illustration.

Hinge cover (large)

Hinge cover (small)

Summary of Contents for DF-704

Page 1: ...t case instead of the illustrations use the appearance of your machine to follow the installation procedure This does not cause any significant change or problem with the procedure 2 Installation proc...

Page 2: ...to push the area indicated by the mark to lock the guide 4 Screw two supplied shoulder screws A into the holes in the rear 5 Place the dual scan document feeder in position 6 Using two supplied mount...

Page 3: ...n in the illustration Note This step may not be performed depending on the applicable marketing area Only the harness shown in the illustration must be routed through the clamp Make sure that there is...

Page 4: ...he illustration 17 Route the cable of the dual scan document feeder inside the harness guides of the main body Note There should be no slack in the cable on the board box side 18 To install the covers...

Page 5: ...uch Exit on the Service Mode screen 10 Turn OFF and ON the power switch Note When displayed the Service Mode screen be sure to turn off the power after exiting the Service Mode screen and wait for 10...

Page 6: ...ouch Auto Adjust 5 Place the chart in the document feeding tray with the side having an arrow facing up 6 Press the Start key 7 Check that Adjustment Result is OK and then touch SET 8 Touch END 9 Touc...

Page 7: ...eck Scale on the screen and adjust the plus value by turning the adjusting screw on the backside clockwise Note Adjust the adjusting plate to make the value off set in the plus direction by the amount...

Page 8: ...g tray Make sure that the blank surface of the chart faces up 4 Press the start key The measurement result will be displayed 5 Repeat operations from steps 3 to 4 four more times Five times in total 6...

Page 9: ...ocument feeding tray with the side having an arrow facing up 4 Press the Start key 5 Check that Adjustment Result is OK and then touch SET 6 Touch Sub Scanning Direction 2 Side 7 Place the chart in th...

Page 10: ...ep 21 c Measure the copy sample produced in step 22 24 Check to make sure that the difference of the chart and the sample copy is within the speci fied range Specifications a 0 2 0 mm for the first an...

Page 11: ...moving the document pad pull apart the hook and loop fastener one by one Pulling the mall at once may damage the sponge 4 Remove the cover shown in the illustration Two screws 5 Remove the ground term...

Page 12: ...in step 7 14 Connect the connector of the hookup harness and route the hookup harness into the guide 15 Attach the end of the ground terminal to the place where it was removed in step 5 One screw remo...

Reviews: