background image

SpectraMagic

TM

NX

enables you to perform comprehensive color

inspection and analysis of incoming raw materials, in process

production, and outbound color critical goods and materials in

virtually any industry. With

SpectraMagic

TM

NX

you can insert

digital images with measured data. Measure samples in any of 8

universally accepted color spaces. Select from 15 illuminants, and

up to 40 indices to determine specific color and appearance

properties, such as strength, brightness, haze, yellowness, opacity

and strength. You can even configure up to 3 customized color

equations. Reports range from simple Pass/Fail to trend charts,

histograms, color plots, and spectral graphs.

SpectraMagic

TM

NX

comes with predefined templates using skin technology, or you can

create your own templates. For illustrations and explanations to

understanding color and color measurement technology, there is a

link to Konica Minolta's well known and respected “Precise Color

Communication”. Step by step navigation help.

• Windows

®

is a trademark of Microsoft Corporation in the USA and

other countries.

Supports Windows

®

2000/XP/Vista

SpectraMagic

TM

NX

(Optional)

Performance

Fast, simultaneous measurement of Specular Included and Specular

Excluded components (SCI/SCE)

Versatility

Full wavelength range 360-740nm with 10nm pitch

Reliability

CM-3600d and CM-3610d Spectrophotometer:

Highest Quality in Color Measurement

in the Laboratory and for Production

High reliability design with fewest moving parts of any benchtop

spectrophotometer

Large (6") sphere; di:8

°

, de:8

°

geometry

Reflectance and transmittance sample measurements

Changeable measurement areas (ø4mm,ø8mm,or ø25.4mm)

View finder design for easy sample viewing

Compact and lightweight

Fast, Instantaneous numerical UV adjustment enables

UV-included, UV-excluded, and UV-adjusted data to be obtained

simultaneously

Precise inter-instrument agreement.

All CM-3600d spectrophotometers meet published inter-instrument

agreement.

Maintenance free technology

and ruggedness concept

The CM-3600d is equipped with maintenance-free technology

and solid state components to withstand rugged conditions.

The monolith polychromator unit assures highest durability and

stability. With one exception (Observing Lens), the CM-3600d

does not use any moving parts. Furthermore, each CM-3600d

passes a hard endurance test program to comply with KONICA

MlNOLTA's highest quality standards in accordance with

ISO-9001.

Compact but yet Powerful

Behind the compact and space-

saving design, you'll

find the skills of a top-

class instrument with

6" large sphere and

other functions so far

only found in much

larger and more

expensive

Full range of application coverage

Konica Minolta Innovative

Optical System Technology

Multiple measurement area selection

For high-accuracy color control

The newly designed Monolith Polychromator Unit

Bright and clear

sample viewing system

Designed to meet your highest

ergonomic expectations

1.Numerical Gloss Control

Enhanced Performance Technology

Konica Minolta Innovative Optical System

2.Numerical UV Control

This technology also provides:

SCI

specular component included

SCE specular component excluded

UV-adjusted data

LAV

25.4mm

MAV

8mm

SAV

4mm

Konica Minolta's Innovative Optical System, including

Numerical Gloss Control and Numerical UV Control,

opens the way to unlimited application versatility at a

price level never seen before.

Whatever your sample looks like, with the CM-3600d you can measure it!

Reflectance of opaque samples, Transmittance of transparent liquids or solids and

Diffuse Transmittance of translucent materials such as plastics - the CM-3600d is

truly versatile.

Transmittance Measurement-The CM-3600d employs the d:0

°

geometry (diffused lighting, 0

°

viewing), which conforms to ISO,

DIN, CIE, and ASTM standards.

Reflectance Measurement-The

CM-3600d employs di:8

°

, de:8

°

geometry (diffused lighting, 8

°

from

normal viewing) which conforms to

JlS7 ISO, DIN, CIE and ASTM

standards.

consists of a diffraction grating with a full wavelength range, 360-740 nm,

at 10nm pitch, and 10nm half-band width, both for sample and reference

light, and dual-channel sensor array.

The retro mirror's reflected and

illuminated sample viewing

screen minimizes fatigue and

allows trouble-free sample

observation.

The compact and space-saving body as well

as all functions of the CM-3600d have been

designed to ensure easy and fatigue-free

operation in daily use. The bright mirror

sample viewing system, the sample holder

for up to A4 size samples with full 90

°

lock

down, and the versatile Transmittance

chamber for liquid or translucent samples

are all just where you expect them to be for

easy operation.

To cover all kinds of samples, the CM-3600d gives you

the choice among three aperture sizes: LAV 25.4mm,

MAV 8mm and SAV 4mm with precise measurement

spot adjustment by a motorized observing lens.

The CM-3600d and CM-3610d are equipped with Konica Minolta Innovative

Optical System technology. For users, this means high accuracy and

repeatability, improved performance, additional features, simple operation,

and - low, affordable pricing.

Instead of using a mechanically driven gloss trap,

the CM-3600d and CM-3610d feature a patented

numerical Gloss (SCl/SCE) control system.

By sequentially firing two flashes, within a few

seconds the system provides both SCI and SCE

values for each sample.

To replace the time-consuming traditional UV

measurement system that utilizes moving filters,

the CM-3600d introduces yet another patented

numerical calculation system, which is also part

of the CM-3610d: The measured values of two

sequentially fired flashes, one with full UV ener-

gy and one with UV cut-off filter at either 400 or

420 nm are combined to obtain the spectral

characteristics, and the respective whiteness

and tint value of any UV-activated fluorescence

sample. To avoid triplet effect on FWA treated

samples, the CM-3600d and CM-3610d can be

set to Soft-Flash mode. Numerical UV Control

technology makes faster, more effective and

reliable measurements of FWA treated materials

such as textiles, papers and detergents.

Mac OS 10.3.9J illustrator 10J

CM-3600d/3610d_inside.ai 2007.11.15

Reviews: