background image

+/.)#!-)./,4!3%.3).').#

/SAKA*APAN

+ONICA-INOLTA3ENSING!MERICAS)NC

New Jersey, U.S.A.  

0HONE

 888-473-2656(in USA), 201-236-4300(outside USA) 

&AX

201-785-2480

+ONICA-INOLTA3ENSING%UROPE"6

European Headquarter /BENELUX  Nieuwegein, Netherland 

0HONE

 +31(0)30 248-1200 

&AX

+31(0)30 248-1211

 

German Office (International) 

Langenhagen, Germany 

0HONE

 +49(0)511 7404-862 

&AX

+49(0)511 7404-807

 

German Office (Germany) 

München, Germany 

0HONE

 +49(0)89 630267-20 

&AX

+49(0)89 630267-67

 

French Office 

Roissy CDG, France 

0HONE

 +33(0)1 493-82519 

&AX

+33(0)1 493-84771

 

UK Office 

Milton Keynes, United Kingdom 

0HONE

 +44(0)1908 540-622 

&AX

+44(0)1908 540-629

 

Italian Office 

Milan, Italy 

0HONE

 +39(0)23 90111 

&AX

+39(0)23 9011219

 

Swiss Office 

Dietikon, Switzerland 

0HONE

 +41(0)43 322-9800 

&AX

+41(0)43 322-9809

 

Nordic Office 

Västra Frölunda, Sweden 

0HONE

 +46(0)31 7099464 

&AX

+46(0)31 474945

 

Austrian Office 

Wien, Austria  

0HONE

 +43(0)1 87882-430 

&AX

+43(0)1 87882-431

 

Polish Office 

Warszawa, Poland  

0HONE

 +48(0)22 56033-00 

&AX

+48(0)22 56033-01

+ONICA-INOLTA#().! )NVESTMENT,TD

SE Sales Division 

Shanghai, China   

0HONE

 +86-021-5489 0202 

&AX

+86-021-5489 0005

 

SE Beijing Office 

Beijing, China  

0HONE

 +86-010-8522 1551 

&AX

+86-010-8522 1241

3%'UANGZHOU/FFICE

'UANGZHOU#HINA

0HONE

 

&AX

+ONICA-INOLTA3ENSING3INGAPORE0TE,TD

3INGAPORE

0HONE

&AX

+/.)#!-)./,4!3%.3).').#

3EOUL/FFICE

3EOUL+OREA

0HONE

&AX

 

HTTPKONICAMINOLTACOMABOUTSECONTACTHTML

!DDRESSESANDTELEPHONEFAXNUMBERSARESUBJECTTOCHANGEWITHOUTNOTICE&ORTHELATESTCONTACTINFORMATION
PLEASEREF/.)#!-)./,4!3%.3).'7ORLDWIDE/FFICESWEBPAGELINKBELOW

Main Specifications CA-2000

AHCDPK

Printed in Japan

9242-4883-21

¢

2005 KONICA MINOLTA SENSING, INC.

4

SAFETY PRECAUTIONS

For correct use and for your safety, be sure to read the instruction
manual before using the instrument.

Always  connect  the  instrument  to  the  specified  power  supply 
voltage. Improper connection may cause a fire or electric shock.

CA-S20w System Requirements

OS 

 

Windows

®

 XP Professional SP2 (Japanese, English, and Hangul versions)

 

 

Windows

®

 XP Professional x 64 Edition (Japanese, English versions)

CPU

 

Pentium

®

 4   2.8 GHz equivalent or higher 

Memory

 

1024 MB or more 

Hard Disk

  Needs free space of 80 MB at least on system drive (where OS is installed)

 

 

In addition, each lens needs the following free spaces for installing calibration data.

 

 

For standard lens: approx. 540 MB

 

 

For wide lens: approx. 470 MB

 

 

For telephoto lens: approx. 1.3 GB

 

 

Also to save measurement data on hard disk, additional free space is required.

 

 

(approx. 11 GB minimum for 1000 measurement data in resolution of 980 x 980)

Display

 

Display capable of at least 1280 x 1024 dots/65,536 colors (High color, 16 bit) .

Others

 

CD-ROM drive (necessary to install software)

 

 

DVD-ROM drive (necessary to install calibration data)

 

 

(A combination drive capable of reading both CD-R and DVD-R media can be used in place of the above 2 drives.)

 

 

USB port: USB ver. 2.0; Type A connector; For connecting measuring instrument

 

 

Excel

®

 2003 (Necessary for continuous measurements using automation)

• Windows

®

,

 

Excel

®

 is a registered trademark or a trademark of Microsoft Corporation in the United States and other 

countries.

• Pentium

®

 is a registered trademark or a trademark of Intel Corporation in the United States and other countries.

The specifications and drawings given here are 
subject to change without prior notice.
- If you have any questions about specifications, 
please contact your Konica Minolta representative.
- The specifications given here are subject to 
change without prior notice.

*1: 

 

Error in angle of view:

 7% 

 

 

 

*2:

   Measurement time differs depending on brightness of measurement object, PC performance, and data processing 

contents.

 

The specifications above were obtained under Konica Minolta's measurement conditions shown below: 

PC's CPU 

Pentium 4, 2.8GHz 

 

 

 

 

Data processing  :

   Pseudocolor display of luminance data

 

Resolution 

:  

490 x 490

 

Shutter speed 

:   Y measurement : 

1/64 sec., 

XZ measurement : 

1/32 sec. 

 

Measurement subject brightness:  Standard/wide lens: 

Approx. 80 cd/m

2

Telephoto lens: 

Approx. 300 cd/m

2

 

 

Low-magnification macro ring and telephoto lens: 

Approx. 400 cd/m

2

 

 

High-magnification macro ring and telephoto lens:

 Approx. 600 cd/m

2

    

 

*

  

The measurement time becomes longer when the object is dark. The longest measurement time is approx. 10 seconds with 

1-time integration, approx. 27 seconds with 4-time integration, approx. 95 seconds with 16-time integration, approx. 6 minutes 

and 8 seconds with 64-time integration and approx. 24 minutes and 19 seconds with 256-time integration

*3:

  The specifications above were obtained under Konica Minolta's measurement conditions shown below: 

Measurement subject brightness: Standard/wide lens:

 Approx. 35 cd/m

2

Telephoto lens: 

Approx. 140 cd/ m

2

 

 

Low-magnification macro ring and telephoto lens:

 Approx. 250 cd/m

2

,  

 

High-magnification macro ring and telephoto lens: 

Approx. 250 cd/m

2

 

Distance: 

Minimum distance of each lens, 

Evaluation: 

Based on the average obtained within 10% range at the 

center of the screen, 

Temperature: 

23°C±2°C, 

Relative humidity: 

40%±10%, 

Measuring light: 

White, reference 

light source, 

Integration: 

64 times (Normal mode)

*4: 

  The specifications above were obtained under Konica Minolta's measurement conditions shown below: 

Resolution:

 196 x 196, 

Shutter speed: Y measurement: 

1/64 sec.,

 XZ measurement: 

1/32 sec. 

G a in :

  N o r mal 

(x1), 

Light intensity level: 

Midpoint of appropriate light intensity range, 

Evaluation:

 Based on the maximum repeat-

ability (2 

 

) of all pixels, 

Temperature: 

23°C±2°C, 

Relative humidity:

 40%±10%, 

Measurement subject: 

White, reference light source, 

Integration: 

64 times (Normal mode) 

*5:

   The specifications above were obtained under Konica Minolta's measurement conditions shown below: 

Measurement subject brightness: Standard/wide lens: 

Approx. 40 cd/m

2

Telephoto lens:

 Approx. 160 cd/m

2

 

 

Low-magnification macro ring and telephoto lens:

 Approx. 200 cd/m

2

,

  

 

High-magnification macro ring and telephoto lens: 

Approx. 350 cd/m

2

 

Distance: 

Calibration distance of each lens, 

Resolution: 

196 x 196

 

Evaluation 

(*6)

  :

 Based on the maximum/minimum values obtained in a square at the center of the screen measur-

ing 60% of the height and width of the entire screen 

 

                 

 (*7) 

:

 Based on the maximum/minimum values obtained in the entire screen

 

Temperature: 

23°C±2°C, 

Relative humidity: 

40%±10%, 

Measurement subject:

 White, reference light source, 

Integration: 

64 times (Normal mode) 

*8: 

 

Even if the instrument is stored within the specified usage (or storage) temperature humidity range, the displayed 

value may change depending on long-period usage or storage conditions.

Model

CA-2000S

CA-2000W

CA-2000T

Light receptor

CCD image sensor (monochrome); 2/3-inch; Effective number of pixels: 1,000 x 1,000 pixels; Equipped with XYZ filter (closely matches CIE 1931 color-
matching function) and ND filter 

Lens

Interchangeable      Standard, wide, and telephoto lenses; low-magnification and high-magnification macro rings (for use with telephoto lens)

Measurement points (Resolution)

980 x 980 (Available to select 490

 

x 490 or 196 x 196 by using Data Management Software CA-S20w)

Color indication modes

XYZ, Lvxy, Lvu’v’, T uv, Dominant wavelength, Excitation purity, Lv contrast

Display modes

Pseudocolor, RGB image, Chromaticity diagram, Spot, 3D graph, Histgram, Nonuniformity enhancement, Cross section, Color difference, Multi-screen

Measurement sizes

 (length per side of square) 

(*1)

Standard lens

Wide lens

Telephoto lens

With low-magnification macro ring With high-magnification macro ring

Approx. 98 mm or more 
(depending on the distance)

Approx. 145 mm or more 
(depending on the distance)

Approx. 115 mm or more
 (depending on the distance)

Approx. 57mm (Fixed)

Approx. 27mm (Fixed)

Measurable size for typical measure-

ment distances (size/distance)

98 mm / 250 mm mm Approx.

145 mm / 200 mm  Approx.

115 mm / 900 mm  Approx.

57 mm / 500 mm  Approx.
(Fixed)

27 mm / 300 mm  Approx.
(Fixed)

210 mm / 500 mm  Approx.

410 mm / 500 mm  Approx.

275 mm / 2,000 mm  Approx.

440 mm / 1,000 mm  Approx.

850 mm / 1,000 mm  Approx.

420 mm / 3,000 mm  Approx.

890 mm / 2,000 mm  Approx.

1,770 mm/ 2,000 mm  Approx.

Measurement luminance range

 (including ND filter use) 

0.1 - 100,000 cd/m

2

0.1 - 100,000 cd/m

2

0.5 - 100,000 cd/m

2

0.5 - 100,000 cd/m

2

1 - 100,000 cd/m

2

Measurement time 

(*2)

Single : Approx. 5 sec. or more; 4-time integration: Approx. 6 sec. or more; 16-time integration: Approx. 10 sec. or more; 64-time integration : Approx. 28 sec. 
or more; 256-time integration : Approx. 98 sec. or more

Accuracy 

(*3)

Luminance

±3 % 

±3 % 

±3 % 

±3 % 

±3 %

Chromaticity 

±0.005

±0.005

±0.005

±0.005

±0.005

Temperature/humidity drift (within the operating temperature/humidity range)
Luminance: ±2% of change compared to reference temperature and relative humidity of 23°C and 40%
Chromaticity: ±0.004 of change compared to reference temperature and relative humidity of 23°C and 40%

Repeatability 

(*4) 

Luminance

0.5 % 

0.5 % 

0.5 % 

0.5 % 

0.5 % 

Chromaticity 

0.001

0.001

0.001

0.001

0.001

Inter-point error 

(*5) 

Luminance 

(*6) 

±2 % 

±2 % 

±2 % 

±2 % 

±2 % 

Chromaticity 

(*6) 

±0.002

±0.002

±0.002

±0.002

±0.002

Luminance 

(*7) 

±3 %

±3 % 

±3 % 

±3 % 

±3 % 

Chromaticity

 (*7) 

±0.003

±0.003

±0.003

±0.003

±0.003

Other functions

Interval measurement, Measurement sync (Synchronization frequency selectable), Integration function, Enhanced nonuniformity display, Conversion of en-

hanced nonuniformity image into numerical values (statistical values, etc.), Pixel binning function

Interface

USB 2.0 or higher

Operating temperature and humidity range

 (*8)

10-30°C, Relative humidity 70% or less/No condensation

Storage temperature and humidity range

 (*8)

0-30°C, Relative humidity 70% or less/No condensation,  30-35°C, Relative humidity 55% or less/No condensation

Size

Body only 

160 (W) × 164 (H) × 199 (D) mm (Height including handle: 211 mm)

When lens and lens hood are attached

224 (D) mm

219 (D) mm

224 (D) mm

230 (D) mm

237 (D) mm

Weight 

3.5 kg approx. (when standard lens and lens hood are attached)

Power source 

AC adapter  100-240 V   , 1.2 A, 50-60 Hz 

Standard 

accessories 

Lens Hood 

CA-A68

CA-A69

CA-A68

CA-A70

Hood Cap 

CA-A71

CA-A75

CA-A71

Calibration data DVD 

Included with each lens.

Other

Mount Cover CA-A61, AC Adapter AC-A22, AC cable, USB Cable IF-A18, Data Management Software CA-S20w

Optional accessories 

Soft Case CA-A60, Tripod CS-A3, Pan Head CS-A4, Calibration certificate