(mm)
200
250
300
500
900
1000
1500
2000
3000
4000
5000
98
121
212
393
439
665
892
1345
1798
2252
Measurable display size
(inches)
16
:
9
4.4
5.5
9.6
18
20
30
40
61
81
102
4
:
3
4.8
6
10.4
19
22
33
44
66
89
111
145
190
235
416
779
869
1323
1776
2682
3589
4495
16
:
9
6.5
8.6
11
19
35
39
60
80
121
162
203
4
:
3
7.1
9.3
12
20
38
43
65
87
132
177
221
116
130
203
275
420
566
711
16
:
9
5.2
5.9
9.2
12
19
26
32
4
:
3
5.7
6.4
10
14
21
28
35
57
16
:
9
2.5
4
:
3
2.8
27
16
:
9
1.2
4
:
3
1.3
Standard lens
Wide lens
Telephoto lens
Low magnification
macro ring
High magnification
macro ring
Distance
Measurement
size
(mm)
Measurable display size
(inches)
Measurement
size
(mm)
Measurable display size
(inches)
Measurement
size
(mm)
Measurable display size
(inches)
Measurement
size
(mm)
Measurable display size
(inches)
Measurement
size
(mm)
2D Color Analyzer CA-2000 for quick, accurate measurement of luminance and chromaticity distribution !
2D COLOR ANALYZER
CA−2000
199
155
9.3
160
47
211.3
223.5
14
14
60
Tripod Socket
UNC 1/4, Depth: 6.5
Hole for positioning pin
60
M5, Depth: 6.5
95.2
125.2
Reference Position
52.8
113
97
Rubber foot diameter: 15
When standard lens and lens hood are attached
<Reference position>
2D COLOR ANALYZER
CA−2000
MADE IN JAPAN
XXXXXX
1
USE ONLY AC-A21
AC ADAPTER:12V ,4A
WARNING:
WARNUNG: Niemals das gehause offnen.
Do not remove covers.
警告:カバーを開けないでください。
12
4
Wide Lens
CA-A73
Mount Cover
CA-A61
Soft Case
CA-A60
Standard accessories
Tripod
CS-A3
Pan Head
CS-A4
Data Management
Software
CA-S20w
AC Adapter
AC-A22
USB cable
IF-A18
(3 m)
CA-2000
Main Unit
Personal computer
(commercial product)
Hood Cap
(For wide lens)
CA-A75
Lens Hood
(For wide lens)
CA-A69
Standard Lens
CA-A72
Hood Cap
CA-A71
Lens Hood
(For standard/telephoto lens)
CA-A68
Telephoto Lens
CA-A74
Hood Cap
CA-A71
Lens Hood
(For standard/telephoto lens)
CA-A68
Lens Hood
(For macro measurement)
CA-A70
Low-magnification
Macro1
High-magnification
Macro2
Optional accessories
Compact & l
ightweigh
t design
enables e
asy setup a
nywhere!
q
2D Color Analyzer (with standard lens)
CA-2000S
w
2D Color Analyzer (with wide lens)
CA-2000W
e
2D Color Analyzer (with telephoto lens)
CA-2000T
Combination of
q
and
w
(with standard and wide lenses)
CA-2000SW
Combination of
q
and
e
(with standard and telephoto lenses)
CA-2000ST
Combination of
w
and
e
(with wide and telephoto lenses)
CA-2000WT
Combination of
q
,
w
and
e
(with all lenses)
CA-2000A
Components other than those shown in the areas shaded
are common for all packages.
*
Each lens comes with a lens cap, mount cap, and calibration data DVD.
Standard
Telephoto
Wide
q
w
e
Telephoto Macro 1
Telephoto Macro 2
Telephoto
Telephoto Macro 1
Telephoto Macro 2
Model with telephoto lens
Wide
Model with wide lens
Standard
Model with standard lens
Lens hood for standard/
telephoto lenses
Wide lens
Lens hood for
wide lens
Macro rings
Telephoto lens
Lens hood for macro
measurement
Lens hood for standard/
telephoto lenses
Main unit
S
ensor with XYZ filters offers high
correlation to the sensitivity of the
human eye
The instrument features a sensor with XYZ filters to
offer spectral response that correlates closely with the
CIE1931 color-matching functions, instead of the RGB
color-separation filters used in digital cameras or color
CCD cameras. This ensures luminance/chromaticity
measurements that correlate well with evaluation by
human eyes.
H
igh-resolution one-million-pixel
CCD
Enables accurate measurements of even small areas.
I
n t e r c h a n g e a b l e l e n s e s f o r
measurements of various objects
The instrument can be used for various applications by
selecting the optimum lens from standard, wide-angle
and telephoto lenses (plus two types of macro rings for
telephoto lens) according to the size of the object.
I
ndividual lens calibration using
multiple focal points
Each lens is individually calibrated for the sensitivity
fluctuations caused by sensors, optical filters and
the lens itself, using multiple focal points. Accurate
m e a s u r e m e n t of l u m i n a n c e a n d c h r o m a t i c i t y
distribution can be started immediately after purchase.
E
asy operation with included
software
O
ther functions
• Synchronized measurement is available by numerical
input of the sync frequency for the subject display
device. (Settable range: 4 to 2,000 Hz)
• Integration of a maximum of 256 measurements
ensures accurate measurements of even low
luminance.
• User calibration for luminance and chromaticity.
• Backlight cancel function compensates for the effect
of backlight variations when performing evaluation.
Dimensions
(Unit: mm)
System Configuration
Sys
tem
Measurable object size with typical measurement distances
(Width/height of measurement square)
Siz
e