![Konica Minolta BIZHUB 164 Service Manual Download Page 92](http://html1.mh-extra.com/html/konica-minolta/bizhub-164/bizhub-164_service-manual_1992961092.webp)
Theory of Operation
V
er. 1.1 Apr. 2010
23. FA
N
CO
N
TROL
61
bizhub 164
COMPOSITION/
OPERA
TION
23. FA
N
CO
N
TROL
23.1 Configuration
23.2 Operation
23.2.1
Function
23.2.2
Fan control
A0XXT2C542AA
DC power supply fan motor (FM5)
Ozone filter
Motor
N
ame
Function (purpose)
DC power supply
fan motor (FM5)
• A fan motor draws air from the area around the fusing unit to the out-
side to prevent the machine interior temperature from running high. in
addition, the fan motor pulls paper being transported up through suc-
tion force to help stabilize paper transport.
• Ozone produced from the drum charge corona is absorbed by the
ozone filter from the air drawn by a fan motor to the outside.
Motor
N
ame
Control
Control Conditions
DC power supply fan motor
(FM5)
O
N
(high
speed)
• During rotation of the main motor (M1)
O
N
(medium
speed)
•
N
o control
O
N
(low
speed)
•
N
o control
Stop
• Conditions other than those of O
N
(high speed)